Diagnostic accuracy of CT angiography in infants with tetralogy of Fallot with pulmonary atresia and major aortopulmonary collateral arteries

被引:36
|
作者
Meinel, Felix G. [1 ,2 ]
Huda, Walter [1 ]
Schoepf, U. Joseph [1 ,3 ,5 ]
Rao, Anil G. [1 ]
Cho, Young Jun [1 ,4 ]
Baker, G. Hamilton [5 ]
Hlavacek, Anthony M. [1 ,5 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29401 USA
[2] Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany
[3] Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29401 USA
[4] Konyang Univ, Coll Med, Dept Radiol, Taejon, South Korea
[5] Med Univ S Carolina, Dept Pediat, Charleston, SC 29401 USA
关键词
Tetralogy of Fallot; Pulmonary atresia; Major aortopulmonary collateral arteries; CT angiography; Congenital heart disease; MAGNETIC-RESONANCE ANGIOGRAPHY; REPAIR;
D O I
10.1016/j.jcct.2013.11.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: CT angiography (CTA) is increasingly used for the evaluation of congenital heart disease. Objective: The aim was to determine the diagnostic accuracy of CTA in infants with tetralogy of Fallot with pulmonary atresia (ToF-PA) and major aortopulmonary collateral arteries (MAPCAs). Methods: We retrospectively evaluated 18 consecutive patients (7 girls; median age, 6 days; range, 1-334 days) with ToF-PA and MAPCAs. Findings on CTA were compared with diagnostic catheterization (n = 16) or intraoperative findings (n = 2) for the number of MAPCAs, their diameter, origin, and supplied lung lobes and for the presence and diameter of central pulmonary arteries. Spearman correlation coefficient was calculated to assess the correlation between diameter measurements on CTA and catheterization. CTA dose-length product and catheterization dose-area product were recorded, and effective radiation doses were calculated with the use of age-specific conversion factors. Results: Agreement was found between CTA and catheterization or intraoperative findings for the number of MAPCAs, their origin, and supplied lung lobes in all cases. In 11 of 13 patients, CTA accurately demonstrated central pulmonary arteries. A good correlation was found between diameter measurements on CTA and catheterization for MAPCAs (r = 0.83) and central pulmonary arteries (r = 0.82). Median effective doses were 0.9 mSv for CTA and 14.4 mSv for catheterization (P <.001). Conclusion: CTA is accurate in the preoperative evaluation of infants with ToF-PA and MAPCAs and is associated with a substantially lower radiation dose than catheterization. Preoperative diagnostic catheterization, therefore, may only be necessary in select patients with small MAPCAs in whom the precise assessment of central pulmonary arteries is required for surgical planning. (C) 2013 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:367 / 375
页数:9
相关论文
共 50 条
  • [31] UNCLEAR ETIOLOGY OF PROFOUND RESPIRATORY FAILURE REQUIRING ECMO AFTER PA RECONSTRUCTION AND REPAIR OF TETRALOGY OF FALLOT WITH PULMONARY ATRESIA, AND MAJOR AORTOPULMONARY COLLATERAL ARTERIES
    Jin, Richard
    Clapcich, Anthony
    ANESTHESIA AND ANALGESIA, 2019, 128 : 709 - 709
  • [32] Aortic valve replacement in a 41-year-old woman with uncorrected tetralogy of Fallot, pulmonary atresia, and major aortopulmonary collateral arteries: a case report
    Saito, Kazutomo
    Iwasaki, Yudai
    Tasaki, Takahiro
    Saito, Hidehisa
    Toyama, Hiroaki
    Ejima, Yutaka
    Yamauchi, Masanori
    JA CLINICAL REPORTS, 2023, 9 (01)
  • [33] Risk stratification for multiple aortopulmonary collaterals by echocardiography in infants with tetralogy of Fallot and pulmonary atresia
    Mackie, AS
    Gauvreau, K
    Perry, SB
    Del Nido, PJ
    Geva, T
    CIRCULATION, 2001, 104 (17) : 355 - 355
  • [34] FUNCTIONAL-ROLE OF MAJOR SYSTEMIC-TO-PULMONARY COLLATERAL ARTERIES IN PATIENTS WITH TETRALOGY OF FALLOT AND PULMONARY VALVULAR ATRESIA
    LIAO, PK
    JULSRUD, PR
    EDWARDS, WD
    FELDT, RH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (02) : 556 - 556
  • [35] Angiographic Anatomy of Major Aortopulmonary Collateral Arteries and Association With Early Surgical Outcomes in Tetralogy of Fallot
    Adamson, Gregory T.
    McElhinney, Doff B.
    Zhang, Yulin
    Feinstein, Jeffrey A.
    Peng, Lynn F.
    Ma, Michael
    Algaze, Claudia A.
    Hanley, Frank L.
    Perry, Stanton B.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (24):
  • [36] Assessment of airway abnormalities in patients with tetralogy of Fallot, pulmonary atresia, and major aortopulmonary collaterals
    Wise-Faberowski, Lisa
    Irvin, Matthew
    Sidell, Douglas R.
    Rajashekara, Sheila
    Asija, Ritu
    Chan, Frandics P.
    Hanley, Frank L.
    McElhinney, Doff B.
    CARDIOLOGY IN THE YOUNG, 2019, 29 (05) : 610 - 614
  • [37] Stenting of the right ventricular outflow tract as an initial intervention in Tetralogy of Fallot with pulmonary stenosis and major aortopulmonary collateral arteries
    Abumehdi, Mohammad
    Sasikumar, Deepa
    Chaudhari, Milind
    Bhole, Vinay
    Botha, Phil
    Mehta, Chetan
    Stumper, Oliver
    CARDIOLOGY IN THE YOUNG, 2021, 31 (03) : 452 - 459
  • [38] Reprint of Staged Repair of Tetralogy of Fallot with Pulmonary Atresia and Major Aortopulmonary Collateral Arteries (Reprinted from vol 12, pg 110-140, 2007)
    Kurosawa, Hiromi
    PROGRESS IN PEDIATRIC CARDIOLOGY, 2009, 26 (02) : 71 - 95
  • [39] Successful Fontan procedure for asplenia with pulmonary atresia and major aortopulmonary collateral arteries
    Miyaji, K
    Nagata, N
    Matsui, H
    Miyamoto, T
    Kitahori, K
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (05): : 1648 - 1650
  • [40] Preoperative total pulmonary blood flow predicts right ventricular pressure in patients early after complete repair of tetralogy of Fallot and pulmonary atresia with major aortopulmonary collateral arteries
    Grosse-Wortmann, Lars
    Yoo, Shi-Joon
    van Arsdell, Glen
    Chetan, Devin
    Macdonald, Cathy
    Benson, Lee
    Honjo, Osami
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (05): : 1185 - 1190