Diagnostic accuracy of CT angiography in infants with tetralogy of Fallot with pulmonary atresia and major aortopulmonary collateral arteries

被引:36
|
作者
Meinel, Felix G. [1 ,2 ]
Huda, Walter [1 ]
Schoepf, U. Joseph [1 ,3 ,5 ]
Rao, Anil G. [1 ]
Cho, Young Jun [1 ,4 ]
Baker, G. Hamilton [5 ]
Hlavacek, Anthony M. [1 ,5 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29401 USA
[2] Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany
[3] Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29401 USA
[4] Konyang Univ, Coll Med, Dept Radiol, Taejon, South Korea
[5] Med Univ S Carolina, Dept Pediat, Charleston, SC 29401 USA
关键词
Tetralogy of Fallot; Pulmonary atresia; Major aortopulmonary collateral arteries; CT angiography; Congenital heart disease; MAGNETIC-RESONANCE ANGIOGRAPHY; REPAIR;
D O I
10.1016/j.jcct.2013.11.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: CT angiography (CTA) is increasingly used for the evaluation of congenital heart disease. Objective: The aim was to determine the diagnostic accuracy of CTA in infants with tetralogy of Fallot with pulmonary atresia (ToF-PA) and major aortopulmonary collateral arteries (MAPCAs). Methods: We retrospectively evaluated 18 consecutive patients (7 girls; median age, 6 days; range, 1-334 days) with ToF-PA and MAPCAs. Findings on CTA were compared with diagnostic catheterization (n = 16) or intraoperative findings (n = 2) for the number of MAPCAs, their diameter, origin, and supplied lung lobes and for the presence and diameter of central pulmonary arteries. Spearman correlation coefficient was calculated to assess the correlation between diameter measurements on CTA and catheterization. CTA dose-length product and catheterization dose-area product were recorded, and effective radiation doses were calculated with the use of age-specific conversion factors. Results: Agreement was found between CTA and catheterization or intraoperative findings for the number of MAPCAs, their origin, and supplied lung lobes in all cases. In 11 of 13 patients, CTA accurately demonstrated central pulmonary arteries. A good correlation was found between diameter measurements on CTA and catheterization for MAPCAs (r = 0.83) and central pulmonary arteries (r = 0.82). Median effective doses were 0.9 mSv for CTA and 14.4 mSv for catheterization (P <.001). Conclusion: CTA is accurate in the preoperative evaluation of infants with ToF-PA and MAPCAs and is associated with a substantially lower radiation dose than catheterization. Preoperative diagnostic catheterization, therefore, may only be necessary in select patients with small MAPCAs in whom the precise assessment of central pulmonary arteries is required for surgical planning. (C) 2013 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:367 / 375
页数:9
相关论文
共 50 条
  • [21] Echocardiographic predictors of aortopulmonary collaterals in infants with tetralogy of Fallot and pulmonary atresia
    Mackie, AS
    Gauvreau, K
    Perry, SB
    del Nido, PJ
    Geva, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (05) : 852 - 857
  • [22] Surgical Management of Fallot's Tetralogy With Pulmonary Atresia and Major Aortopulmonary Collateral Arteries: Multistage Versus One-Stage Repair
    Carotti, Adriano
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2020, 11 (01) : 34 - 38
  • [23] Bronchoscopy in children with tetralogy of fallot, pulmonary atresia, and major aortopulmonary collaterals
    Sidell, Douglas R.
    Koth, Andrew M.
    Bauser-Heaton, Holly
    McElhinney, Doff B.
    Wise-Faberowski, Lisa
    Tracy, Michael C.
    Hanley, Frank L.
    Asija, Ritu
    PEDIATRIC PULMONOLOGY, 2017, 52 (12) : 1599 - 1604
  • [24] A Noninvasive Circulating Signature of Combined Right Ventricular Pressure and Volume Overload in Tetralogy of Fallot/Pulmonary Atresia/Major Aortopulmonary Collateral Arteries
    Clouthier, Katie L.
    Taylor, Anne C.
    Ji, Xuhuai
    Liu, Yuhan
    Parker, Sarah
    Van Eyk, Jennifer
    Reddy, Sushma
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2024, 15 (02) : 162 - 173
  • [25] Intraesophageal aortopulmonary collateral artery occlusion in an infant with Tetralogy of Fallot and flow-dependent major aortopulmonary collateral arteries
    Lawson, Katy L.
    Wong, Vanessa
    Finn, J. Paul
    Fishbein, Gregory A.
    CARDIOVASCULAR PATHOLOGY, 2019, 39 : 74 - 76
  • [26] Tetralogy of Fallot associated with pulmonary atresia and major aortopulmonary collateral arteries in a patient with interstitial deletion of 16q21-q22.1
    Yamamoto, Toshiyuki
    Dowa, Yuri
    Ueda, Hideaki
    Kawataki, Motoyoshi
    Asou, Toshihide
    Sasaki, Yuki
    Harada, Naoki
    Matsumoto, Naomichi
    Matsuoka, Rumiko
    Kurosawa, Kenji
    AMERICAN JOURNAL OF MEDICAL GENETICS PART A, 2008, 146A (12) : 1575 - 1580
  • [27] Pregnancy with uncorrected tetralogy of Fallot (TOF), pulmonary atresia and major aorto-pulmonary collateral arteries (MAPCA)
    Gomez, Luis M.
    Jones, Ryan C.
    Fuertes, Maria R.
    Tate, Danielle L.
    Ramanathan, Jaya
    CASE REPORTS IN PERINATAL MEDICINE, 2018, 7 (01):
  • [28] Pulmonary atresia with ventricular septal defect and major aortopulmonary collateral arteries
    Bonnet, C
    Agnoletti, G
    Boudjemline, Y
    Beyler, C
    Sidi, D
    Vouhé, P
    Bonnet, D
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2005, 98 (05): : 471 - 476
  • [29] Durability of Aortic Homografts in Pulmonary Atresia and Major Aortopulmonary Collateral Arteries
    Ragheb, Daniel K.
    Martin, Elisabeth
    Zhang, Yulin
    Jaggi, Ayush
    Asija, Ritu
    Peng, Lynn F.
    Ma, Michael
    Hanley, Frank L.
    McElhinney, Doff B.
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2024,
  • [30] Aortic valve replacement in a 41-year-old woman with uncorrected tetralogy of Fallot, pulmonary atresia, and major aortopulmonary collateral arteries: a case report
    Kazutomo Saito
    Yudai Iwasaki
    Takahiro Tasaki
    Hidehisa Saito
    Hiroaki Toyama
    Yutaka Ejima
    Masanori Yamauchi
    JA Clinical Reports, 9