Optical Coherence Tomography Findings in Lesions After Sirolimus-Eluting Stent Implantation With Peri-Stent Contrast Staining

被引:29
|
作者
Tada, Takeshi [1 ]
Kadota, Kazushige [1 ]
Hosogi, Shingo [2 ]
Kubo, Shunsuke [1 ]
Ozaki, Masatomo [1 ]
Yoshino, Mitsuru [1 ]
Miyake, Koshi [1 ]
Eguchi, Haruki [1 ]
Ohashi, Noriyuki [1 ]
Hayakawa, Yuki [1 ]
Saito, Naoki [1 ]
Otsuru, Suguru [1 ]
Hasegawa, Daiji [1 ]
Shigemoto, Yoshikazu [1 ]
Habara, Seiji [1 ]
Imai, Masao [3 ]
Tanaka, Hiroyuki [1 ]
Fuku, Yasushi [1 ]
Oka, Naoki [1 ]
Kato, Harumi [1 ]
Yamamoto, Hiroyuki [1 ]
Fujii, Satoki [1 ]
Goto, Tsuyoshi [1 ]
Mitsudo, Kazuaki [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Cardiovasc Med, Kurashiki, Okayama 7108602, Japan
[2] Kochi Hlth Sci Ctr, Dept Cardiovasc Med, Kochi, Japan
[3] Kyoto Univ, Dept Cardiovasc Med, Grad Sch Med, Kyoto, Japan
关键词
peri-stent contrast staining; optical coherence tomography; incomplete stent apposition; multiple interstrut hollows; INTRAVASCULAR ULTRASOUND FINDINGS; BARE-METAL; APPOSITION; THROMBOSIS; HYPERSENSITIVITY; RESTENOSIS; PATTERNS; INSIGHTS;
D O I
10.1161/CIRCINTERVENTIONS.112.968487
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-We have sometimes noted abnormal angiographic coronary dilatation, <50% of the reference vessel, at the site of sirolimus-eluting stent implantation, suggesting contrast staining outside the stent struts and named this finding peri-stent contrast staining (PSS). Little was known about optical coherence tomography findings of lesions with PSS. Methods and Results-Between May 2008 and March 2010, we performed optical coherence tomography for 90 in-stent restenosis lesions after sirolimus-eluting stent implantation. We found PSS in 20 of the 90 lesions by coronary angiography. The differences in optical coherence tomography findings, including incomplete stent apposition, multiple interstrut hollows (MIH), strut coverage, and thrombus, were compared between lesions with PSS and those without PSS. PSS is defined as contrast staining outside the stent contour extending to >20% of the stent diameter measured by quantitative coronary angiography. MIH is defined as multiple hollows (the maximum depth >0.5 mm) existing between and outside well-apposed stent struts. Both incomplete stent apposition (60.0% versus 10%; P<0.001) and MIH (85.0% versus 25.7%; P<0.001) were frequently observed in lesions with PSS than in lesions without PSS. Among the 20 lesions with PSS, there was only 1 lesion in which we found neither MIH nor incomplete stent apposition, but only minor dissection. Uncovered struts (11.6% versus 3.9%; P=0.001), malapposed struts (2.0% versus 0.0%; P<0.001), and red thrombus (35% versus 10%; P=0.012) were frequently observed in lesions with PSS than in lesions without PSS. Conclusions-PSS might be closely associated with 2 different optical coherence tomography findings, MIH and incomplete stent apposition, in lesions after sirolimus-eluting stent implantation. (Circ Cardiovasc Interv. 2012;5:649-656.)
引用
下载
收藏
页码:649 / 656
页数:8
相关论文
共 50 条
  • [41] Occurrence of Late Acquired Peri-Stent Contrast Staining Comparison Between Sirolimus-Eluting Stents and Everolimus-Eluting Stents
    Fujiwara, Takayuki
    Sakakura, Kenichi
    Ako, Junya
    Wada, Hiroshi
    Arao, Kenshiro
    Sugawara, Yoshitaka
    Momomura, Shin-ichi
    INTERNATIONAL HEART JOURNAL, 2012, 53 (03) : 165 - 169
  • [42] Stent fracture and peri-stent contrast staining after everolimus-eluting stent implantation: 5-year clinical outcome
    Miura, Katsuya
    Kadota, Kazushige
    Kuwayama, Akimune
    Ohya, Masanobu
    Shimada, Takenobu
    Amano, Hidewo
    Kubo, Shunsuke
    Hyodo, Yusuke
    Otsuru, Suguru
    Habara, Seiji
    Tada, Takeshi
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B130 - B130
  • [43] NEOINTIMAL APPEARANCE OF LATE RESTENOSIS AFTER SIROLIMUS-ELUTING STENT IMPLANTATION: AN OPTICAL COHERENCE TOMOGRAPHY STUDY
    Ino, Yasushi
    Shimamura, Kunihiro
    Shiono, Yasutsugu
    Komukai, Kenichi
    Ishibashi, Kohei
    Satogami, Keisuke
    Orii, Makoto
    Tanimoto, Takashi
    Kitabata, Hironori
    Masuno, Tomizou
    Kimura, Keizo
    Nakanishi, Hiroko
    Hirata, Kumiko
    Kubo, Takashi
    Tanaka, Atsushi
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1868 - E1868
  • [44] Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation
    Takano, Masamichi
    Inami, Shigenobu
    Jang, Ik-Kyung
    Yamamoto, Masanori
    Murakami, Daisuke
    Seimiya, Koji
    Ohba, Takayoshi
    Mizuno, Kyoichi
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (08): : 1033 - 1038
  • [45] Appearance of Peri-stent Contrast Staining in Everolimus Eluting Stent After Target Vessel Revascularization
    Yamamoto, Wataru
    Otsuji, Satoru
    Hasegawa, Katsuyuki
    Ishibuchi, Kasumi
    Higashino, Yorihiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (15) : S269 - S270
  • [46] Very Late Stent Thrombosis after Sirolimus-Eluting Stent Implantation Observed Using Optical Coherence Tomography and Coronary Angioscopy
    Ikenaga, Hiroki
    Dai, Kazuoki
    Ishihara, Masaharu
    JOURNAL OF INVASIVE CARDIOLOGY, 2010, 22 (11): : 557 - 558
  • [47] Very Late Stent Thrombosis 5 Years After Implantation of a Sirolimus-Eluting Stent Observed by Angioscopy and Optical Coherence Tomography
    Ishihara, Takayuki
    Awata, Masaki
    Fujita, Masashi
    Watanabe, Tetsuya
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Uematsu, Masaaki
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (05) : E28 - E30
  • [48] Time-Dependent Changes of Local Vascular Response and Angiographic Peri-Stent Contrast Staining up to Five Years After Zotarolimus-Eluting, Sirolimus-Eluting, and Bare Metal Stent Implantation
    Yamaguchi, Koji
    Wakatsuki, Tetsuzo
    Ise, Takayuki
    Tobiume, Takeshi
    Yagi, Syusuke
    Iwase, Takashi
    Yamada, Hirotsugu
    Soeki, Takeshi
    Sata, Masataka
    CIRCULATION, 2013, 128 (22)
  • [49] FAVORABLE NEOINTIMAL COVERAGE IN EVEROLIMUS-ELUTING STENT AT 9 MONTH AFTER STENT IMPLANTATION: COMPARISON WITH SIROLIMUS-ELUTING STENT USING OPTICAL COHERENCE TOMOGRAPHY
    Choi, Hyun-Hee
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    Sim, Won-Heum
    Cho, Seung-Yun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [50] Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography
    Hyun Hee Choi
    Jung-Sun Kim
    Duck Hyoung Yoon
    Kyung-Soon Hong
    Tae Hoon Kim
    Byeong Keuk Kim
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    The International Journal of Cardiovascular Imaging, 2012, 28 : 491 - 497