Optical Coherence Tomography Findings in Lesions After Sirolimus-Eluting Stent Implantation With Peri-Stent Contrast Staining

被引:29
|
作者
Tada, Takeshi [1 ]
Kadota, Kazushige [1 ]
Hosogi, Shingo [2 ]
Kubo, Shunsuke [1 ]
Ozaki, Masatomo [1 ]
Yoshino, Mitsuru [1 ]
Miyake, Koshi [1 ]
Eguchi, Haruki [1 ]
Ohashi, Noriyuki [1 ]
Hayakawa, Yuki [1 ]
Saito, Naoki [1 ]
Otsuru, Suguru [1 ]
Hasegawa, Daiji [1 ]
Shigemoto, Yoshikazu [1 ]
Habara, Seiji [1 ]
Imai, Masao [3 ]
Tanaka, Hiroyuki [1 ]
Fuku, Yasushi [1 ]
Oka, Naoki [1 ]
Kato, Harumi [1 ]
Yamamoto, Hiroyuki [1 ]
Fujii, Satoki [1 ]
Goto, Tsuyoshi [1 ]
Mitsudo, Kazuaki [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Cardiovasc Med, Kurashiki, Okayama 7108602, Japan
[2] Kochi Hlth Sci Ctr, Dept Cardiovasc Med, Kochi, Japan
[3] Kyoto Univ, Dept Cardiovasc Med, Grad Sch Med, Kyoto, Japan
关键词
peri-stent contrast staining; optical coherence tomography; incomplete stent apposition; multiple interstrut hollows; INTRAVASCULAR ULTRASOUND FINDINGS; BARE-METAL; APPOSITION; THROMBOSIS; HYPERSENSITIVITY; RESTENOSIS; PATTERNS; INSIGHTS;
D O I
10.1161/CIRCINTERVENTIONS.112.968487
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-We have sometimes noted abnormal angiographic coronary dilatation, <50% of the reference vessel, at the site of sirolimus-eluting stent implantation, suggesting contrast staining outside the stent struts and named this finding peri-stent contrast staining (PSS). Little was known about optical coherence tomography findings of lesions with PSS. Methods and Results-Between May 2008 and March 2010, we performed optical coherence tomography for 90 in-stent restenosis lesions after sirolimus-eluting stent implantation. We found PSS in 20 of the 90 lesions by coronary angiography. The differences in optical coherence tomography findings, including incomplete stent apposition, multiple interstrut hollows (MIH), strut coverage, and thrombus, were compared between lesions with PSS and those without PSS. PSS is defined as contrast staining outside the stent contour extending to >20% of the stent diameter measured by quantitative coronary angiography. MIH is defined as multiple hollows (the maximum depth >0.5 mm) existing between and outside well-apposed stent struts. Both incomplete stent apposition (60.0% versus 10%; P<0.001) and MIH (85.0% versus 25.7%; P<0.001) were frequently observed in lesions with PSS than in lesions without PSS. Among the 20 lesions with PSS, there was only 1 lesion in which we found neither MIH nor incomplete stent apposition, but only minor dissection. Uncovered struts (11.6% versus 3.9%; P=0.001), malapposed struts (2.0% versus 0.0%; P<0.001), and red thrombus (35% versus 10%; P=0.012) were frequently observed in lesions with PSS than in lesions without PSS. Conclusions-PSS might be closely associated with 2 different optical coherence tomography findings, MIH and incomplete stent apposition, in lesions after sirolimus-eluting stent implantation. (Circ Cardiovasc Interv. 2012;5:649-656.)
引用
下载
收藏
页码:649 / 656
页数:8
相关论文
共 50 条
  • [21] Unusual peri-stent strut contrast staining 6 years after sirolimus-eluting stent implantation: an "ant colony-like" appearance
    Neishi, Yoji
    Okura, Hiroyuki
    Yoshida, Kiyoshi
    HEART AND VESSELS, 2014, 29 (05) : 699 - 702
  • [22] Characteristics of angiographic Peri-Stent contrast Staining (PSS) on very late stent thrombosis after sirolimus-eluting stent implantation: morphological classification and antiplatelet therapy
    Imai, M.
    Kimura, T. K.
    EUROPEAN HEART JOURNAL, 2013, 34 : 872 - 872
  • [23] Contribution of organized thrombus to in-stent restenosis after sirolimus-eluting stent implantation: optical coherence tomography findings
    Fujii, Kenichi
    Masutani, Motomaru
    Ohyanagi, Mitsumasa
    EUROPEAN HEART JOURNAL, 2008, 29 (11) : 1385 - 1385
  • [24] Exacerbated Peri-Stent Contrast Staining on Serial Angiography and Optical Coherence Tomography After Platinum-Chromium Everolimus-Eluting Stent Implantation for Infrapopliteal Artery Lesions
    Tomoi, Yusuke
    Kuramitsu, Shoichi
    Soga, Yoshimitsu
    Hiramori, Seiichi
    Ando, Kenji
    INTERNATIONAL HEART JOURNAL, 2018, 59 (04) : 895 - 898
  • [25] Nine-year follow-up of progressive peri-stent contrast staining after Cypher sirolimus-eluting stent implantation: a case report
    Hyogo M.
    Sawada T.
    Shiraishi J.
    Kohno Y.
    Cardiovascular Intervention and Therapeutics, 2017, 32 (3) : 279 - 286
  • [26] Impact of Dual Antiplatelet Therapy Beyond 1 Year on Clinical Outcomes of Patients With Stent Fracture or Peri-Stent Contrast Staining After Sirolimus-Eluting Stent Implantation
    Fuku, Yasushi
    Kadota, Kazushige
    Amano, Hidewo
    Kubo, Shunsuke
    Otsuru, Suguru
    Habara, Seiji
    Tada, Takeshi
    Tanaka, Hiroyuki
    Goto, Tsuyoshi
    CIRCULATION JOURNAL, 2018, 82 (01) : 211 - +
  • [27] The association between stent fracture and peri-stent contrast staining after drug-eluting stent implantation
    Tada, T.
    Kadota, K.
    Tanaka, H.
    Hosogi, S.
    Fuku, Y.
    Yamamoto, H.
    Goto, T.
    Mitsudo, K.
    EUROPEAN HEART JOURNAL, 2011, 32 : 84 - 84
  • [28] Difference in Optical Coherence Tomography Findings of Very Late In-Stent Restenosis Lesions Between After Bare-Metal Stent and Sirolimus-Eluting Stent Implantation
    Tada, Takeshi
    Kadota, Kazushige
    Habara, Seiji
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    Mitsudo, Kazuaki
    CIRCULATION, 2014, 130
  • [29] Prevalence and Clinical Implications of Peri-Stent Contrast Staining, Stent Thrombosis and Stent Fracture After Drug-Eluting Stent Implantation in Bifurcation Lesions
    Saito, Naoki
    Kadota, Kazushige
    CIRCULATION, 2011, 124 (21)
  • [30] Very late stent thrombosis associated with multiple stent fractures and peri-stent aneurysm formation after sirolimus-eluting stent implantation
    Lee, Shin-Eun
    John, Sung-Hee
    Lim, Ji-Hyun
    Rhew, Jay-Young
    CIRCULATION JOURNAL, 2008, 72 (07) : 1201 - 1204