Monitoring Morphological Changes in the Retina of Rhodopsin-/- Mice with Spectral Domain Optical Coherence Tomography

被引:20
|
作者
Wang, Ruilin [1 ,2 ]
Jiang, Caihui [1 ]
Ma, Jie [1 ]
Young, Michael J. [1 ]
机构
[1] Harvard Univ, Massachusetts Eye & Ear Infirm, Sch Med, Schepens Eye Res Inst,Dept Ophthalmol, Boston, MA 02114 USA
[2] Huazhong Univ Sci & Technol, Tongji Med Sch, Tongji Hosp, Dept Ophthalmol, Wuhan 430074, Peoples R China
关键词
MOUSE; TRANSPLANTATION; CELLS; MODEL;
D O I
10.1167/iovs.12-9716
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The rhodopsin(-/-) C57Bl/6 (rho(-/-)) mouse is a very important model for understanding retinal degenerative diseases. In this study, spectral domain optical coherence tomography (SD-OCT) was used to monitor the dynamic morphological changes in retina of rho(-/-) mice. METHODS. Rho(-/-) mice and wild type C57Bl/6 (B6) mice at the age of 3, 6, 9, and 12 weeks were investigated using SD-OCT to obtain cross-sectional images of the retina. The outer nuclear layer (ONL) thickness was measured. Histological sections were used to compare to the OCT data. Electroretinograms (ERG) were performed to evaluate the physiological change for establishing the relationship between retinal morphology and its functional changes. RESULTS. There was no apparent morphological or functional change in B6 mice at any time point. The SD-OCT measurement showed that the ONL thickness in rho(-/-) mice was significantly decreased from 40.6 mu m to 6.0 mu m from week 3 to week 12 postnatal. Histological examinations identified a similar trend, although the average thickness of ONL from histological sections at these time points was slightly larger (ranging from 55.4 mu m to 14.9 mu m). The ERG in rho(-/-) mice indicated functional changes that were in concordant with morphological changes; a significant linear positive association was identified between the amplitude of b-wave and the ONL thickness. CONCLUSIONS. Our findings confirmed that the functional changes in retina were concordant with morphological changes measured by SD-OCT in vivo, which indicates that SD-OCT can be used as a reliable noninvasive method to monitor the degenerative progression in retinal disease models. Invest Ophthalmol Vis Sci. 2012;53:3967-3972) DOI:10.1167/iovs.12-9716
引用
收藏
页码:3967 / 3972
页数:6
相关论文
共 50 条
  • [21] High speed spectral domain polarization sensitive optical coherence tomography of the human retina
    Götzinger, E
    Pircher, M
    Hitzenberger, CK
    OPTICS EXPRESS, 2005, 13 (25): : 10217 - 10229
  • [22] Monitoring Small Changes in Blood Hematocrit Using Phase Sensitive Spectral Domain Optical Coherence Tomography
    Manne, Venu Gopal Reddy
    Manapuram, Ravi Kiran
    Sudheendran, Narendran
    Larin, Kirill V.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [23] Spectral calibration in spectral domain optical coherence tomography
    Wang, Kai
    Ding, Zhihua
    CHINESE OPTICS LETTERS, 2008, 6 (12) : 902 - 904
  • [24] Spectral calibration in spectral domain optical coherence tomography
    王凯
    丁志华
    ChineseOpticsLetters, 2008, 6 (12) : 902 - 904
  • [25] The assessment of morphological changes in the retina in amblyopia using optical coherence tomography image segmentation
    Tatrai, Erika
    Szigeti, Andrea
    Szamosi, Anna
    Vargha, Peter
    Nagy, Zoltan Zsolt
    Nemeth, Janos
    DeBuc, Delia
    Somfai, Gabor Mark
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [26] Multirate Spectral Domain Optical Coherence Tomography
    Gaur, Prabhav
    Grieco, Andrew
    Fainman, Yeshaiahu
    IEEE PHOTONICS JOURNAL, 2023, 15 (05):
  • [27] Spectral domain optical coherence tomography interpretation
    Blacklaws, Jake
    Seamone, Mark E.
    Gupta, R. Rishi
    BRITISH JOURNAL OF HAEMATOLOGY, 2018, 181 (05) : 710 - 710
  • [28] Imaging Modality in Diagnosis and Monitoring of Glaucoma: Spectral Domain Optical Coherence Tomography
    Surak Patanakanog
    Teresa C. Chen
    Current Ophthalmology Reports, 2016, 4 (4) : 173 - 179
  • [29] Online monitoring of printed electronics by Spectral-Domain Optical Coherence Tomography
    Alarousu, Erkki
    AlSaggaf, Ahmed
    Jabbour, Ghassan E.
    SCIENTIFIC REPORTS, 2013, 3
  • [30] Online monitoring of printed electronics by Spectral-Domain Optical Coherence Tomography
    Erkki Alarousu
    Ahmed AlSaggaf
    Ghassan E. Jabbour
    Scientific Reports, 3