Ambulatory instrument for monitoring indirect beat-to-beat blood pressure in superficial temporal artery using volume-compensation method

被引:19
|
作者
Tanaka, S [1 ]
Yamakoshi, K [1 ]
机构
[1] KANAZAWA UNIV,FAC ENGN,KANAZAWA,ISHIKAWA 920,JAPAN
关键词
ambulatory monitoring; beat-to-beat blood pressure; non-invasive measurement; superficial temporal artery; volume-compensation method;
D O I
10.1007/BF02523848
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A portable instrument, based on a volume-compensation technique, is designed for ambulatory monitoring of indirect beat-to-beat blood pressure (BP) in the superficial temporal artery. The instrument consists of a small disc-type cuff and a portable unit carried by the subject. Several components are integrated in the cuff for applying counter-pressure to the artery, i.e. a reflectance-type photo-plethysmographic sensor for arterial volume detection, a pressure sensor for cuff pressure P-c measurement and a nozzle flapper-type electro-pneumatic convertor for controlling P-c. The portable unit includes volume servo control circuitry and a microprocessor-based signal-processing and recording unit. This automatically performs all the necessary measurement procedures and stores into a memory le element the processed systolic, mean and diastolic blood pressure data, together with pulse intervals on a beat-to-beat basis from the servo-controlled P-c (indirectly measured BP waveform). With this instrument, momentary changes in BP during ambulatory situations such as bicycle ergometer exercise and daily activities including motorway driving are successfully recorded. From the results of simultaneous measurement of the subject's posture changes, the effect of posture change on blood pressure, e.g. baroreceptor-cardiac reflex, is also clearly demonstrated.
引用
收藏
页码:441 / 447
页数:7
相关论文
共 50 条
  • [1] AMBULATORY MONITORING OF INDIRECT BEAT-TO-BEAT ARTERIAL-PRESSURE IN HUMAN FINGERS BY A VOLUME-COMPENSATION METHOD
    KAWARADA, A
    SHIMAZU, H
    ITO, H
    YAMAKOSHI, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (01) : 55 - 62
  • [2] Accuracy assessment of a noninvasive device for monitoring beat-by-beat blood pressure in the radial artery using the volume-compensation method
    Tanaka, Shinobu
    Nogawa, Masamichi
    Yamakoshi, Takehiro
    Yamakoshi, Ken-Ichi
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (10) : 1892 - 1895
  • [3] ADOPTION OF CONTINUOUS BEAT-TO-BEAT NOCTURNAL BLOOD PRESSURE MEASUREMENT IN AMBULATORY BLOOD PRESSURE MONITORING
    Estrada, Sebastian
    Kwon, Younghoon
    Baruch, Martin
    Harrison, Elizabeth
    Williams, Ronald
    Cho, Yeilim
    Gerdt, David
    Bonner, Heather
    Mazimba, Sula
    Berry, Richard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1893 - 1893
  • [4] Ambulatory and beat-to-beat blood pressure variability: Are they related?
    Sloan, RP
    Shapiro, PA
    Bagiella, E
    McKinley, PS
    Myers, MM
    Brondolo, EN
    Eichler, B
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 172 - 172
  • [5] Beat-to-beat ambulatory blood pressure variability is different from intermittent ambulatory blood pressure variability
    Sloan, RP
    Berg, J
    Bagiella, E
    Chernikhova, D
    Myers, MM
    PSYCHOSOMATIC MEDICINE, 1998, 60 (01): : 109 - 109
  • [6] Beat-to-beat ambulatory blood pressure estimation based on random forest
    He, Rui
    Huang, Zhi-Pei
    Ji, Lian-Ying
    Wu, Jian-Kang
    Li, Huihui
    Zhang, Zhi-Qiang
    2016 IEEE 13TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2016, : 194 - 198
  • [7] Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring
    Kim, Joshua
    Chou, En-Fan
    Le, Jamie
    Wong, Sabrina
    Chu, Michael
    Khine, Michelle
    ADVANCED HEALTHCARE MATERIALS, 2019, 8 (13)
  • [8] Blood pressure measurements in research: suitability of auscultatory, beat-to-beat, and ambulatory blood pressure measurements
    Carlson, Debra J.
    Dieberg, Gudrun
    Mcfarlane, James R.
    Smart, Neil A.
    BLOOD PRESSURE MONITORING, 2019, 24 (01) : 18 - 23
  • [9] A portable instrument for non-invasive monitoring of beat-by-beat cardiovascular haemodynamic parameters based on the volume-compensation and electrical-admittance method
    Nakagawara, M
    Yamakoshi, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (01) : 17 - 25
  • [10] A portable instrument for non-invasive monitoring of beat-by-beat cardiovascular haemodynamic parameters based on the volume-compensation and electrical-admittance method
    M. Nakagawara
    K. Yamakoshi
    Medical and Biological Engineering and Computing, 2000, 38 : 17 - 25