Ambulatory instrument for monitoring indirect beat-to-beat blood pressure in superficial temporal artery using volume-compensation method

被引:19
|
作者
Tanaka, S [1 ]
Yamakoshi, K [1 ]
机构
[1] KANAZAWA UNIV,FAC ENGN,KANAZAWA,ISHIKAWA 920,JAPAN
关键词
ambulatory monitoring; beat-to-beat blood pressure; non-invasive measurement; superficial temporal artery; volume-compensation method;
D O I
10.1007/BF02523848
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A portable instrument, based on a volume-compensation technique, is designed for ambulatory monitoring of indirect beat-to-beat blood pressure (BP) in the superficial temporal artery. The instrument consists of a small disc-type cuff and a portable unit carried by the subject. Several components are integrated in the cuff for applying counter-pressure to the artery, i.e. a reflectance-type photo-plethysmographic sensor for arterial volume detection, a pressure sensor for cuff pressure P-c measurement and a nozzle flapper-type electro-pneumatic convertor for controlling P-c. The portable unit includes volume servo control circuitry and a microprocessor-based signal-processing and recording unit. This automatically performs all the necessary measurement procedures and stores into a memory le element the processed systolic, mean and diastolic blood pressure data, together with pulse intervals on a beat-to-beat basis from the servo-controlled P-c (indirectly measured BP waveform). With this instrument, momentary changes in BP during ambulatory situations such as bicycle ergometer exercise and daily activities including motorway driving are successfully recorded. From the results of simultaneous measurement of the subject's posture changes, the effect of posture change on blood pressure, e.g. baroreceptor-cardiac reflex, is also clearly demonstrated.
引用
收藏
页码:441 / 447
页数:7
相关论文
共 50 条
  • [21] Beat-to-beat Blood Pressure Variability, Cerebrovascular Reactivity, and White Matter Lesion Volume In Older Adults
    Lohman, Trevor
    Sible, Isabel
    Engstrom, Allie
    Kapoor, Arunima
    Shenasa, Fatemah
    Gaubert, Aimee
    Nguyen, Amy
    Shao, Xingfeng
    Wang, Danny
    Nation, Daniel
    CIRCULATION, 2024, 150
  • [22] Heritability of Ambulatory and Beat-to-Beat Office Blood Pressure in Large Multigenerational Arab Pedigrees: The 'Oman Family Study'
    Albarwani, Sulayma
    Munoz, M. Loretto
    Voruganti, V. Saroja
    Jaju, Deepali
    Al-Yahyaee, V. Saeed
    Rizvi, Syed G.
    Lopez-Alvarenga, Juan C.
    Al-Anqoudi, Zahir M.
    Bayoumi, Riad A.
    Comuzzie, Anthony G.
    Snieder, Harold
    Hassan, Mohammed O.
    TWIN RESEARCH AND HUMAN GENETICS, 2012, 15 (06) : 753 - 758
  • [23] Impedance cardiography and beat-to-beat blood pressure monitoring in diagnosis of syncope in long-QT syndrome
    Pozza, RD
    Kleinmann, A
    Bechtold, S
    Netz, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 2005, 94 (11): : 767 - 771
  • [24] Prognostic Significance of Blood Pressure Variability on Beat-to-Beat Monitoring After Transient Ischemic Attack and Stroke
    Webb, Alastair J. S.
    Mazzucco, Sara
    Li, Linxin
    Rothwell, Peter M.
    STROKE, 2018, 49 (01) : 62 - +
  • [25] CONTINUOUS BEAT TO BEAT AMBULATORY BLOOD PRESSURE MONITORING: INITIAL EXPERIENCE IN SUSTAINED UNCONTROLLED HYPERTENSIVES (SUCH)
    Kotliar, Carol
    Obregon, Sebastian
    JOURNAL OF HYPERTENSION, 2021, 39 : E143 - E143
  • [26] Short-term beat-to-beat but not ambulatory blood pressure variability is correlated to carotid intima-media thickness
    Manios, Efstathios
    Michas, Fotios
    Stamatelopoulos, Kimon
    Barlas, Gerasimos
    Koroboki, Eleni
    Tsouma, Iliana
    Vemmos, Konstantinos
    Zakopoulos, Nikolaos
    BLOOD PRESSURE MONITORING, 2014, 19 (05) : 288 - 293
  • [27] Heritability and genetic and environmental correlations of heart rate variability and baroreceptor reflex sensitivity with ambulatory and beat-to-beat blood pressure
    Man, Tengfei
    Riese, Harriette
    Jaju, Deepali
    Munoz, M. Loretto
    Hassan, Mohammed O.
    Al-Yahyaee, Said
    Bayoumi, Riad A.
    Comuzzie, Anthony G.
    Floras, John S.
    van Roon, Arie M.
    Nolte, Ilja M.
    Albarwani, Sulayma
    Snieder, Harold
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [28] A practical guide to active stand testing and analysis using continuous beat-to-beat non-invasive blood pressure monitoring
    Finucane, Ciaran
    van Wijnen, V. K.
    Fan, C. W.
    Soraghan, C.
    Byrne, L.
    Westerhof, B. E.
    Freeman, R.
    Fedorowski, A.
    Harms, M. P. M.
    Wieling, W.
    Kenny, R.
    CLINICAL AUTONOMIC RESEARCH, 2019, 29 (04) : 427 - 441
  • [29] A practical guide to active stand testing and analysis using continuous beat-to-beat non-invasive blood pressure monitoring
    Ciarán Finucane
    V. K. van Wijnen
    C. W. Fan
    C. Soraghan
    L. Byrne
    B. E. Westerhof
    R. Freeman
    A. Fedorowski
    M. P. M. Harms
    W. Wieling
    R. Kenny
    Clinical Autonomic Research, 2019, 29 : 427 - 441
  • [30] Heritability and genetic and environmental correlations of heart rate variability and baroreceptor reflex sensitivity with ambulatory and beat-to-beat blood pressure
    Tengfei Man
    Harriëtte Riese
    Deepali Jaju
    M. Loretto Muñoz
    Mohammed O. Hassan
    Said Al-Yahyaee
    Riad A. Bayoumi
    Anthony G. Comuzzie
    John S. Floras
    Arie M. van Roon
    Ilja M. Nolte
    Sulayma Albarwani
    Harold Snieder
    Scientific Reports, 9