SPR detection of cardiac troponin T for acute myocardial infarction

被引:69
|
作者
Pawula, Maria [1 ]
Altintas, Zeynep [1 ]
Tothill, Ibtisam E. [1 ]
机构
[1] Cranfield Univ, Cranfield MK43 0AL, Beds, England
关键词
Cardiac troponin T; Acute myocardial infarction; SPR; Immunosensor; Early diagnosis; SURFACE-PLASMON RESONANCE; QUARTZ-CRYSTAL MICROBALANCE; SENSITIVE DETECTION; GOLD NANOPARTICLES; SERUM SAMPLES; REAL-TIME; IMMUNOSENSOR; BIOMARKER; CHEMISTRY; BIOSENSOR;
D O I
10.1016/j.talanta.2015.06.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A surface plasmon resonance (SPR) sensor developed for the rapid, sensitive and specific detection of cardiac troponin T (cTnT) in serum samples is reported in this work. An extensive optimisation of assay parameters was conducted to achieve optimal detection strategy. Both direct and sandwich immunoassay formats were investigated and optimised. The response obtained was enhanced further by the use of gold nanoparticles (AuNPs) conjugated to the anti-cTnT detection antibody. A regeneration method was developed to enable the reuse of the SPR sensor for multiple sample application. The SPR immunosensor showed good reproducibility for cTnT detection in the concentration range of 25-1000 ng mL(-1) and 5-400 ng mL(-1) for the direct and sandwich assays in buffer, respectively. The linear regression analysis was performed and R-2 value was found as 0.99 for both assays. In order to optimise the sensor for serum analysis, nonspecific binding of serum proteins was reduced through the use of additives in the dilution buffer. To achieve greater sensitivity, the performance of the cTnT immunosensor sandwich assay in human serum was evaluated using non-modified and AuNP modified detector antibodies. A detection limit (LOD) for the immunosensor in 50% serum was assessed as 5 ng mL(-1) cTnT for the standard sandwich assay and 0.5 ng mL(-1) cTnT when using AuNP conjugated detector antibodies with a linear dynamic range of 0.5-40 ng mL(-1). The dissociation constant was found as 3.28 x 10(-9) M using Langmuir binding model which indicates high affinity between cTnT and its antibody. The proposed SPR immunosensor has a promising potential to be developed for point-of-care testing for the early diagnosis of acute myocardial infarction (AMI). This method can also be used for the rapid detection of biomarkers in central nervous system diseases. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:823 / 830
页数:8
相关论文
共 50 条
  • [41] Cardiac troponin T at 96 hours after acute myocardial infarction correlates with infarct size and cardiac function
    Steen, Henning
    Ciannitsis, Evangelos
    Futterer, Simon
    Merten, Constanze
    Juenger, Claus
    Katus, Hugo A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (11) : 2192 - 2194
  • [42] High-Sensitivity Cardiac Troponin T Concentrations below the Limit of Detection to Exclude Acute Myocardial Infarction: A Prospective Evaluation
    Body, Richard
    Burrows, Gillian
    Carley, Simon
    Cullen, Louise
    Than, Martin
    Jaffe, Allan S.
    Lewis, Philip S.
    CLINICAL CHEMISTRY, 2015, 61 (07) : 983 - 989
  • [43] EVALUATION OF SERUM TROPONIN T MEASUREMENTIN ACUTE MYOCARDIAL INFARCTION
    于宏伟
    赵文娟
    范洪亮
    徐庆科
    苗志敏
    中华医学杂志(英文版), 1995, (07) : 23 - 27
  • [44] EVALUATION OF SERUM TROPONIN T MEASUREMENTIN ACUTE MYOCARDIAL INFARCTION
    于宏伟
    赵文娟
    范洪亮
    徐庆科
    苗志敏
    ChineseMedicalJournal, 1995, (07)
  • [45] Troponin I as a Biomarker for Early Detection of Acute Myocardial Infarction
    Duque-Ossa, L. C.
    Garcia-Ferrera, B.
    Reyes-Retana, J. A.
    CURRENT PROBLEMS IN CARDIOLOGY, 2023, 48 (05)
  • [46] Does Cardiac Troponin I Overestimate Periprocedural Myocardial Infarction When Compared to Cardiac Troponin T?
    Revaiah, Pruthvi Chenniganahosahalli
    Stone, Gregg W.
    Masuda, Shinichiro
    Ninomiya, Kai
    Kotoku, Nozomi
    Kageyama, Shigetaka
    Onuma, Yoshinobu
    Serruys, Patrick W.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (04) : S11 - S12
  • [47] Cardiac troponin and defining myocardial infarction
    Kaier, Thomas E.
    Alaour, Bashir
    Marber, Michael
    CARDIOVASCULAR RESEARCH, 2021, 117 (10) : 2203 - 2214
  • [48] Cardiac troponin testing and myocardial infarction
    Joob, Beuy
    Wiwanitkit, Viroj
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (05): : 732 - 732
  • [49] Is a Single High-Sensitivity Troponin T Assay Accurate for the Detection of Acute Myocardial Infarction?
    Kirschner, Jonathan
    Zahn, Greg
    ANNALS OF EMERGENCY MEDICINE, 2016, 68 (03) : 295 - 297
  • [50] AlphaLISA-Based Immunoassay for Detection of Troponin T in Serum of Patients with Acute Myocardial Infarction
    Lv, Wei
    Li, Qian
    Tang, Yan
    Qin, Yuan
    Zhou, Xiumei
    Zhao, Xueqin
    Zheng, Zhencang
    Huang, Biao
    JOURNAL OF FLUORESCENCE, 2024,