SPR detection of cardiac troponin T for acute myocardial infarction

被引:69
|
作者
Pawula, Maria [1 ]
Altintas, Zeynep [1 ]
Tothill, Ibtisam E. [1 ]
机构
[1] Cranfield Univ, Cranfield MK43 0AL, Beds, England
关键词
Cardiac troponin T; Acute myocardial infarction; SPR; Immunosensor; Early diagnosis; SURFACE-PLASMON RESONANCE; QUARTZ-CRYSTAL MICROBALANCE; SENSITIVE DETECTION; GOLD NANOPARTICLES; SERUM SAMPLES; REAL-TIME; IMMUNOSENSOR; BIOMARKER; CHEMISTRY; BIOSENSOR;
D O I
10.1016/j.talanta.2015.06.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A surface plasmon resonance (SPR) sensor developed for the rapid, sensitive and specific detection of cardiac troponin T (cTnT) in serum samples is reported in this work. An extensive optimisation of assay parameters was conducted to achieve optimal detection strategy. Both direct and sandwich immunoassay formats were investigated and optimised. The response obtained was enhanced further by the use of gold nanoparticles (AuNPs) conjugated to the anti-cTnT detection antibody. A regeneration method was developed to enable the reuse of the SPR sensor for multiple sample application. The SPR immunosensor showed good reproducibility for cTnT detection in the concentration range of 25-1000 ng mL(-1) and 5-400 ng mL(-1) for the direct and sandwich assays in buffer, respectively. The linear regression analysis was performed and R-2 value was found as 0.99 for both assays. In order to optimise the sensor for serum analysis, nonspecific binding of serum proteins was reduced through the use of additives in the dilution buffer. To achieve greater sensitivity, the performance of the cTnT immunosensor sandwich assay in human serum was evaluated using non-modified and AuNP modified detector antibodies. A detection limit (LOD) for the immunosensor in 50% serum was assessed as 5 ng mL(-1) cTnT for the standard sandwich assay and 0.5 ng mL(-1) cTnT when using AuNP conjugated detector antibodies with a linear dynamic range of 0.5-40 ng mL(-1). The dissociation constant was found as 3.28 x 10(-9) M using Langmuir binding model which indicates high affinity between cTnT and its antibody. The proposed SPR immunosensor has a promising potential to be developed for point-of-care testing for the early diagnosis of acute myocardial infarction (AMI). This method can also be used for the rapid detection of biomarkers in central nervous system diseases. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:823 / 830
页数:8
相关论文
共 50 条
  • [21] Novel biomarkers in early diagnosis of acute myocardial infarction compared with cardiac troponin T
    McCann, Conor J.
    Glover, Ben M.
    Menown, Ian B. A.
    Moore, Michael J.
    McEneny, Jane
    Owens, Colum G.
    Smith, Bernie
    Sharpe, Peter C.
    Young, Ian S.
    Adgey, Jennifer A.
    EUROPEAN HEART JOURNAL, 2008, 29 (23) : 2843 - 2850
  • [22] SERUM CARDIAC TROPONIN-T IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION - DETECTION OF CORONARY REPERFUSION AND PREDICTION OF CARDIAC-FUNCTION
    KITAOKA, H
    MIYAZAKI, S
    NONOGI, H
    FURUNO, T
    ITOH, A
    DAIKOKU, S
    NAKAO, K
    YAMAMOTO, Y
    HAZE, K
    JAPANESE HEART JOURNAL, 1995, 36 (03): : 293 - 303
  • [23] Frequency of periprocedural myocardial injury and infarction stratified by cardiac troponin I and cardiac troponin T
    Revaiah, Pruthvi C.
    Tsai, Tsung-Ying
    Wang, Bo
    Renkens, Mick
    Kageyama, Shigetaka
    Wlodarczak, Adrian
    Lemoine, Julien
    Mollmann, Helge
    Sabate, Manel
    Sharif, Faisal
    Zaman, Azfar
    Wykrzykowska, Joanna
    Benit, Edouard
    Qiang, He Xing
    Miyashita, Kotaro
    Tobe, Akihiro
    Muramatsu, Takashi
    Tanabe, Kengo
    Ozaki, Yukio
    Garg, Scot
    Mcevoy, John William
    Neumann, Franz-Josef
    Baumbach, Andreas
    Smits, Peter C.
    Stone, Gregg W.
    Onuma, Yoshinobu
    Serruys, Patrick W.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2025, 70 : 12 - 19
  • [24] Early kinetics of cardiac troponin in suspected acute myocardial infarction
    Gimenez, Maria Rubini
    Wildi, Karin
    Wussler, Desiree
    Koechlin, Luca
    Boeddinghaus, Jasper
    Nestelberger, Thomas
    Badertscher, Patrick
    Sedlmayer, Raphael
    Puelacher, Christian
    Zimmermann, Tobias
    de Lavallaz, Jeanne du Fay
    Lopez-Ayala, Pedro
    Leu, Kathrin
    Rentsch, Katharina
    Miro, Oscar
    Lopez, Beatriz
    Martin-Sanchez, F. Javier
    Bustamante, Jose
    Kawecki, Damian
    Parenica, Jiri
    Lohrmann, Jens
    Kloos, Wanda
    Buser, Andreas
    Keller, Dagmar, I
    Reichlin, Tobias
    Twerenbold, Raphael
    Mueller, Christian
    REVISTA ESPANOLA DE CARDIOLOGIA, 2021, 74 (06): : 502 - 509
  • [25] SYSTEMIC INFLAMMATORY MARKERS AND CARDIAC TROPONIN IN ACUTE MYOCARDIAL INFARCTION
    Bronze, L.
    Andrade, M.
    Relvas, M.
    Arroja, I.
    Morais, G.
    Seabra, M.
    Mendes, M.
    Aleixo, A.
    INTENSIVE CARE MEDICINE, 2012, 38 : S101 - S101
  • [26] Use of cardiac troponin in the early diagnosis of acute myocardial infarction
    Muzyk, Piotr
    Twerenbold, Raphael
    Morawiec, Beata
    Ayala, Pedro Lopez
    Boeddinghaus, Jasper
    Nestelberger, Thomas
    Mueller, Christian
    Kawecki, Damian
    KARDIOLOGIA POLSKA, 2020, 78 (11) : 1099 - 1106
  • [27] Role of salivary cardiac troponin I in acute myocardial infarction
    Vijayvergiya, Rajesh
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2013, 138 : 831 - 831
  • [28] A comparative study of troponin I and troponin T release in acute myocardial infarction
    Goldmann, BU
    Heeschen, C
    Moller, RH
    Hamm, CW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 99035 - 99035
  • [29] Risk stratification with a point-of-care cardiac troponin T test in acute myocardial infarction
    Ohman, EM
    Armstrong, PW
    White, HD
    Granger, CB
    Wilcox, RG
    Weaver, WD
    Gibler, WB
    Stebbins, AL
    Cianciolo, C
    Califf, RM
    Topol, EJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (11): : 1281 - 1286
  • [30] Cardiac troponin T closely correlates with infarct size in a murine model of acute myocardial infarction
    Hammerer-Lercher, A
    Metzler, B
    Mair, J
    Pachinger, O
    Xu, Q
    EUROPEAN HEART JOURNAL, 2001, 22 : 674 - 674