Characterization of the stray light in a space borne atmospheric AOTF spectrometer

被引:13
|
作者
Korablev, Oleg [1 ,2 ]
Fedorova, Anna [1 ,2 ]
Villard, Eric [3 ,4 ]
Joly, Lilian [5 ]
Kiselev, Alexander [1 ,2 ]
Belyaev, Denis [1 ,2 ]
Bertaux, Jean-Loup [3 ]
机构
[1] Space Res Inst IKI, Moscow 117997, Russia
[2] Moscow Inst Phys & Technol, Dolgoprudnyi 141700, Russia
[3] LATMOS CNRS, F-78280 Guyancourt, France
[4] ALMA European So Observ, Santiago, Chile
[5] Univ Reims, GSMA CNRS, F-51687 Reims, France
来源
OPTICS EXPRESS | 2013年 / 21卷 / 15期
关键词
MARS EXPRESS; WATER-VAPOR; FILTER;
D O I
10.1364/OE.21.018354
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Acousto-optic tunable filter (AOTF) spectrometers are being criticized for spectral leakage, distant side lobes of their spectral response function (SRF), or the stray light. SPICAM-IR is the AOTF spectrometer in the range of 1000-1700 nm with a resolving power of 1800-2200 operating on the Mars Express interplanetary probe. It is primarily dedicated to measurements of water vapor in the Martian atmosphere. SPICAM H2O retrievals are generally lower than simultaneous measurements with other instruments, the stray light suggested as a likely explanation. We report the results of laboratory measurements of water vapor in quantity characteristic for the Mars atmosphere (2-15 precipitable microns) with the Flight Spare model of SPICAM-IR. We simulated the measured spectra with HITRAN-based synthetic model, varying the water abundance, and the level of the stray light, and compared the results to the known amount of water in the cell. The retrieved level of the stray light, assumed uniformly spread over the spectral range, is below 1-1.3.10(-4). The stray may be responsible for the underestimation of water abundance of up to 8%, or 0.6 pr. mu m. The account for the stray light removes the bias completely; the overall accuracy to measure water vapor is similar to 0.2 pr. mu m. We demonstrate that the AOTF spectrometer dependably measures the water abundance and can be employed as an atmospheric spectrometer. (C) 2013 Optical Society of America
引用
收藏
页码:18354 / 18360
页数:7
相关论文
共 50 条
  • [41] Orbit environment analysis of the space-borne imaging spectrometer
    Guo, LH
    Zhang, X
    Cong, XJ
    OPTICAL DESIGN AND TESTING, 2002, 4927 : 485 - 490
  • [42] Improving stray-light characterization and correction beyond blooming, the experience of the fluorescence imaging spectrometer optical model refurbished
    Nuzzi, Davide
    De Luca, Emanuela
    Pettinato, Lucia
    Fossati, Enrico
    Gabrieli, Riccardo
    Baroni, Marco
    Giunti, Lorenzo
    Romano, Jacopo
    Postiglione, Giovanni
    Galeotti, Francesco
    Pompei, Carlo
    Barilli, Marco
    Barillot, Marc
    Taccola, Matteo
    Bellomo, Giampiero
    Pekala, Grzegorz Dariusz
    Veltroni, Iacopo Ficai
    Coppo, Peter
    JOURNAL OF APPLIED REMOTE SENSING, 2024, 18 (03)
  • [43] Stray Light Analysis of a Compact Imaging Spectrometer for a Microsatellite STSAT-3
    Lee, Jin Ah
    Lee, Jun Ho
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2012, 23 (04) : 167 - 171
  • [44] Determination of the stray light levels in a dispersive near-infrared spectrometer with trichloromethane
    Busch, KW
    Soyemi, OO
    Rabbe, D
    Busch, MA
    APPLIED SPECTROSCOPY, 2000, 54 (12) : 1759 - 1766
  • [45] Analysis and Measurement of Stray Light in a Visible and Near-Infrared Imaging Spectrometer
    Luo, Chao
    Chen, Xinhua
    Zhao, Zhicheng
    Pan, Qiao
    Tang, Minxue
    Shen, Weimin
    SIXTH INTERNATIONAL CONFERENCE ON OPTICAL AND PHOTONIC ENGINEERING (ICOPEN 2018), 2018, 10827
  • [46] New approach of stray light suppression for probe system of handheld Raman spectrometer
    Liu, Bing
    Yu, Fanju
    Sun, Qiang
    Liu, Ying
    An, Yan
    Jiang, Chengzhi
    Hu, Xinrong
    Zhongguo Jiguang/Chinese Journal of Lasers, 2014, 41 (01):
  • [47] Stray light analysis for a mid-infrared plane grating spectrometer system
    Liu, Yang
    Fang, Yonghua
    Wu, Jun
    Luo, Jing
    Li, Yangyu
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2015, 44 (04): : 1164 - 1171
  • [48] The stray-light entrance pupil concept and how it can be used to facilitate stray-light characterization
    Clermont, L.
    Michel, C.
    Blain, P.
    Stockman, Y.
    OPTICAL MODELING AND SYSTEM ALIGNMENT, 2019, 11103
  • [49] MEASUREMENT OF ATMOSPHERIC EMISSION USING A BALLOON-BORNE CRYOGENIC FOURIER SPECTROMETER
    SAKAI, H
    LI, TC
    PRITCHARD, J
    MURCRAY, FJ
    MURCRAY, FH
    WILLIAMS, J
    VANASSE, G
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 289 : 196 - 198
  • [50] Characterization and correction of stray light in TROPOMI-SWIR
    Tol, Paul J. J.
    van Kempen, Tim A.
    van Hees, Richard M.
    Krijger, Matthijs
    Cadot, Sidney
    Snel, Ralph
    Persijn, Stefan T.
    Aben, Ilse
    Hoogeveen, Ruud W. M.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2018, 11 (07) : 4493 - 4507