NON-INVASIVE ASSESSMENT OF ELASTIC MODULUS OF ARTERIAL CONSTRUCTS DURING CELL CULTURE USING ULTRASOUND ELASTICITY IMAGING

被引:21
|
作者
Dutta, Debaditya [1 ,2 ,3 ]
Lee, Kee-Won [4 ]
Allen, Robert A. [4 ]
Wang, Yadong [3 ,4 ,5 ,6 ]
Brigham, John C. [4 ,7 ]
Kim, Kang [1 ,2 ,3 ,4 ,6 ]
机构
[1] Univ Pittsburgh, Ctr Ultrasound Mol Imaging & Therapeut, Dept Med & Heart, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Vasc Inst, Pittsburgh, PA 15261 USA
[3] Univ Pittsburgh, Med Ctr, Pittsburgh, PA 15261 USA
[4] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15261 USA
[5] Univ Pittsburgh, Dept Surg, Pittsburgh, PA 15260 USA
[6] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA USA
[7] Univ Pittsburgh, Dept Civil & Environm Engn, Pittsburgh, PA USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2013年 / 39卷 / 11期
关键词
Ultrasound elasticity imaging; Non-invasive assessment; Young's modulus; Inverse problem; Tissue engineering; Arterial construct; MECHANICAL-PROPERTIES; COLLAGEN; SCAFFOLD; ELASTOGRAPHY; BIOREACTOR; EXPRESSION; GRAFT;
D O I
10.1016/j.ultrasmedbio.2013.04.023
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Mechanical strength is a key design factor in tissue engineering of arteries. Most existing techniques assess the mechanical property of arterial constructs destructively, leading to sacrifice of a large number of animals. We propose an ultrasound-based non-invasive technique for the assessment of the mechanical strength of engineered arterial constructs. Tubular scaffolds made from a biodegradable elastomer and seeded with vascular fibroblasts and smooth muscle cells were cultured in a pulsatile-flow bioreactor. Scaffold distension was computed from ultrasound radiofrequency signals of the pulsating scaffold via 2-D phase-sensitive speckle tracking. Young's modulus was then calculated by solving the inverse problem from the distension and the recorded pulse pressure. The stiffness thus computed from ultrasound correlated well with direct mechanical testing results. As the scaffolds matured in culture, ultrasound measurements indicated an increase in Young's modulus, and histology confirmed the growth of cells and collagen fibrils in the constructs. The results indicate that ultrasound elastography can be used to assess and monitor non-invasively the mechanical properties of arterial constructs. (E-mail: kangkim@upmc.edu) (C) 2013 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:2103 / 2115
页数:13
相关论文
共 50 条
  • [21] Non-invasive assessment of inflammation using ultrasound detection of phagocytosed microbubbles
    Lindner, JR
    Song, J
    Coggins, MP
    Xu, F
    Kaul, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 444A - 444A
  • [22] In vivo non-invasive high resolution MR-based method for the determination of the elastic modulus of arterial vessels
    Taviani, Valentina
    Sutcliffe, Michael P. F.
    Wong, Pauline
    Li, Zhi-Yong
    Young, Victoria
    Graves, Martin J.
    Gillard, Jonathan H.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5569 - +
  • [23] Continuous Non-invasive Arterial Pressure Assessment during Surgery to improve Outcome
    Stenglova, Alena
    Benes, Jan
    FRONTIERS IN MEDICINE, 2017, 4
  • [24] Non-invasive monitoring of living cell culture by lensless digital holography imaging
    Wang, Yunxin
    Wang, Dayong
    Zhao, Jie
    Yang, Yishu
    Xiao, Xiangqian
    Cui, Huakun
    CHINESE OPTICS LETTERS, 2011, 9 (03)
  • [25] Non-invasive monitoring of living cell culture by lensless digital holography imaging
    王云新
    王大勇
    赵洁
    杨怡殊
    肖向茜
    崔华坤
    Chinese Optics Letters, 2011, 9 (03) : 25 - 28
  • [26] STEATO-SCORE: NON-INVASIVE QUANTITATIVE ASSESSMENT OF LIVER FAT BY ULTRASOUND IMAGING
    Di Lascio, Nicole
    Avigo, Cinzia
    Salvati, Antonio
    Martini, Nicola
    Ragucci, Monica
    Monti, Serena
    Prinster, Anna
    Chiappino, Dante
    Mancini, Marcello
    D'Elia, Domenico
    Ghiadoni, Lorenzo
    Bonino, Ferruccio
    Brunetto, Maurizia R.
    Faita, Francesco
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (08): : 1585 - 1596
  • [27] Ultrasound super-resolution imaging for non-invasive assessment of microvessel in prostate lesion
    Huang, Xin
    Ye, Huarong
    Hu, Yugang
    Lei, Yumeng
    Tian, Yi
    Huang, Xingyue
    Zhang, Jun
    Zhang, Yao
    Gui, Bin
    Liu, Qianhui
    Zhang, Ge
    Deng, Qing
    CANCER IMAGING, 2025, 25 (01)
  • [28] Non-invasive temperature imaging using ultrasound echo strain: Preliminary simulations
    Bamber, JC
    Meaney, P
    Doyley, MM
    Clarke, RL
    ter Haar, GR
    ACOUSTICAL IMAGING, VOL 23, 1997, 23 : 25 - 33
  • [29] Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement
    Hidehiko Komine
    Yoshiyuki Asai
    Takashi Yokoi
    Mutsuko Yoshizawa
    BioMedical Engineering OnLine, 11
  • [30] Assessment of Psoriatic Skin Features Using Non-Invasive Imaging Technique
    Odrzywolek, Wiktoria
    Deda, Anna
    Zdrada, Julita
    Wcislo-Dziadecka, Dominika
    Lipka-Trawinska, Aleksandra
    Blonska-Fajfrowska, Barbara
    Wilczynski, Slawomir
    PROCESSES, 2022, 10 (05)