Continuous Non-invasive Arterial Pressure Assessment during Surgery to improve Outcome

被引:16
|
作者
Stenglova, Alena [1 ]
Benes, Jan [1 ,2 ]
机构
[1] Charles Univ Prague, Dept Anesthesiol & Intens Care Med, Fac Med Plzen, Plzen, Czech Republic
[2] Charles Univ Prague, Biomed Ctr, Fac Med Plzen, Plzen, Czech Republic
关键词
blood pressure; non-invasive monitoring; volume clamp; vascular unloading; applanation tonometry; intraoperative hypotension; goal-directed hemodynamic therapy; postoperative outcomes; MINIMUM ALVEOLAR CONCENTRATION; INTENSIVE-CARE MEDICINE; LOW BISPECTRAL INDEX; LOW BLOOD-PRESSURE; RANDOMIZED CONTROLLED-TRIAL; CARDIAC-OUTPUT MEASUREMENT; INTRAOPERATIVE HYPOTENSION; NONCARDIAC SURGERY; FINGER CUFF; INTRAARTERIAL MEASUREMENT;
D O I
10.3389/fmed.2017.00202
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Blood pressure (BP) is one of the most important variables evaluated during almost every medical examination. Most national anesthesiology societies recommend BP monitoring at least once every 5 min in anesthetized subjects undergoing surgical procedures. In most cases, BP is monitored non-invasively using oscillometric cuffs. Although the risk of arterial cannulation is not very high, the invasive BP monitoring is usually indicated only in the case of high-risk patients or in complex surgical procedures. However, recent evidence points out that when using intermittent BP monitoring short periods of hypotension may be overlooked. In addition, large datasets have demonstrated that even short periods of low BP (or their cumulative duration) may have a detrimental impact on the development of postoperative outcome including increased risk of acute kidney or myocardial injury development. Recently marketed continuous non-invasive blood pressure monitoring tools may help us to recognize the BP fluctuation without the associated burden of arterial cannulation filling the gap between intermittent non-invasive cuff and continuous invasive arterial pressure. Among others, several novel devices based either on volume clamp/vascular unloading method or on applanation tonometry are nowadays available. Moreover, several near-future smart technologies may lead to better hypotension recognition or even prediction potentially improving our ability to maintain BP stability throughout the anesthesia or surgical procedure. In this review, novel or emerging technologies of non-invasive continuous blood pressure assessment and their potential to improve postoperative outcome are discussed.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] CONTINUOUS NON-INVASIVE ARTERIAL PRESSURE (CNAP) MEASUREMENT: COMPARING THE CNAP DEVICE TO THE NON-INVASIVE BLOOD PRESSURE ARM CUFF DURING SURGERY
    Khera, J. K.
    Solangasenathirajan, S.
    Jones, M.
    Jonas, M.
    INTENSIVE CARE MEDICINE, 2013, 39 : S295 - S295
  • [2] Continuous non-invasive arterial pressure measurement: Evaluation of CNAP™ device during vascular surgery
    Biais, M.
    Vidil, L.
    Roullet, S.
    Masson, F.
    Quinart, A.
    Revel, P.
    Sztark, F.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2010, 29 (7-8): : 530 - 535
  • [3] The application and reliability of continuous non-invasive arterial blood pressure monitoring in elderly patients during surgery
    Zhou, Shuzhi
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 668 - 668
  • [4] Reliability Of Non-Invasive Continuous Arterial Pressure Measurement Devices During Total Invasive Anaesthesia
    Huhle, R.
    Siegert, J.
    de Abreu, M. Gama
    Koch, T.
    Theilen, H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [5] NEXFIN CONTINUOUS NON-INVASIVE ARTERIAL BLOOD PRESSURE VALIDATED WITH INVASIVE BLOOD PRESSURE
    Martina, J. R.
    Westerhof, B. E.
    van Goudoever, J.
    de Beaumont, E. M.
    Hollmann, M. W.
    Lahpor, J. R.
    de Mol, B. A.
    van Lieshout, J. J.
    JOURNAL OF HYPERTENSION, 2009, 27 : S192 - S192
  • [6] Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery
    Fischer, M. O.
    Avram, R.
    Carjaliu, I.
    Massetti, M.
    Gerard, J. L.
    Hanouz, J. L.
    Fellahi, J. L.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (04) : 514 - 521
  • [7] Evaluation of continuous non-invasive arterial pressure monitoring during induction of general anaesthesia in patients undergoing cardiac surgery
    Kumar, Anil G.
    Jagadeesh, A. M.
    Singh, Naveen G.
    Prasad, S. R.
    INDIAN JOURNAL OF ANAESTHESIA, 2015, 59 (01) : 21 - 25
  • [8] Non-invasive continuous blood pressure monitoring vs invasive blood pressure monitoring during vascular surgery
    Subbotin, Valery
    Sitnikov, Alexey
    Bukarev, Alexey
    Malakhova, Anna
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 115 - 115
  • [9] Precision and accuracy of a new device (CNAP™) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia
    Jeleazcov, C.
    Krajinovic, L.
    Muenster, T.
    Birkholz, T.
    Fried, R.
    Schuettler, J.
    Fechner, J.
    BRITISH JOURNAL OF ANAESTHESIA, 2010, 105 (03) : 264 - 272
  • [10] Continuous Non-Invasive Arterial Pressure Technique Improves Patient Monitoring during Interventional Endoscopy
    Siebig, Sylvia
    Rockmann, Felix
    Sabel, Karl
    Zuber-Jerger, Ina
    Dierkes, Christine
    Bruennler, Tanja
    Wrede, Christian E.
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2009, 6 (01): : 37 - 42