The influence of pelvic tilt on acetabular orientation and cover: a three-dimensional computerised tomography analysis

被引:59
|
作者
Dandachli, Wael [1 ]
Ul Islam, Saif [2 ]
Richards, Robin [2 ]
Hall-Craggs, Margaret [3 ]
Witt, Johan [2 ]
机构
[1] Imperial Coll London Hosp, Dept Orthopaed Surg, London, England
[2] Univ Coll London Hosp, Dept Orthopaed Surg, London, England
[3] Univ Coll London Hosp, Dept Radiol, London, England
关键词
Acetabulum; Pelvis; Computed tomography; FEMORAL-HEAD; CT MEASUREMENT; HIP; RETROVERSION; ANTEVERSION; DISLOCATION; ANGLE; IONS;
D O I
10.5301/HIP.2013.10715
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The orientation of the pelvis influences that of the acetabulum. In particular, pelvic tilt in the sagittal plane may lead to inaccurate interpretation of plain pelvic radiographs. We therefore quantified the relationship between this pelvic tilt and acetabular orientation in native hips, and determined whether pelvic tilt affects femoral head cover. We analysed computed tomography scans of 93 hips (36 normal, 31 dysplastic, 26 with acetabular retroversion) and measured acetabular anteversion, inclination, and femoral head cover at pelvic tilt angles ranging from -20 to 20 in relation to the anterior pelvic plane using 5 increments. Pelvic tilt changed acetabular version with a decrease in anteversion ranging from 2.5 to 5 for every 5 of forward tilt. The effect on inclination was less marked and varied. In normal and dysplastic hips pelvic tilt increased apparent femoral head cover. A greater understanding of the influence of pelvic tilt may allow improvements in the radiological diagnosis and surgical treatment of acetabular abnormalities, particularly in relation to acetabular reorientation procedures and femoroacetabular impingement.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 50 条
  • [31] Three-dimensional analysis of pelvic volume in an unstable pelvic fracture
    Stover, Michael D.
    Summers, Hobie D.
    Ghanayem, Alexander J.
    Wilber, John H.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (04): : 905 - 908
  • [32] Scanning precession electron tomography for three-dimensional nanoscale orientation imaging and crystallographic analysis
    Eggeman, Alexander S.
    Krakow, Robert
    Midgley, Paul A.
    NATURE COMMUNICATIONS, 2015, 6
  • [33] Scanning precession electron tomography for three-dimensional nanoscale orientation imaging and crystallographic analysis
    Alexander S. Eggeman
    Robert Krakow
    Paul A. Midgley
    Nature Communications, 6
  • [34] Three-dimensional joint surface orientation does not correlate with two-dimensional coronal joint line orientation in knee osteoarthritis: Three-dimensional analysis of upright computed tomography
    Sasaki, Ryo
    Niki, Yasuo
    Kaneda, Kazuya
    Yamada, Yoshitake
    Nagura, Takeo
    Nakamura, Masaya
    Jinzaki, Masahiro
    KNEE, 2023, 43 : 10 - 17
  • [35] Influence of acetabular and femoral morphology on pelvic tilt A STUDY OF 388 HIPS
    Heimann, A. F.
    Murmann, V.
    Schwab, J. M.
    Tannast, M.
    BONE & JOINT JOURNAL, 2024, 106B (05): : 3 - 10
  • [36] Influence of acetabular and femoral morphology on pelvic tilt - a study in 400 patients
    Heimann, Alexander Frank
    Murmann, Valerie
    Schwab, Jospeh M.
    Tannast, Moritz
    SWISS MEDICAL WEEKLY, 2023, 153 : 74S - 75S
  • [37] The Effect of Postural Pelvic Dynamics on the Three-dimensional Orientation of the Acetabular Cup in THA Is Patient Specific (vol 479, pg 561, 2021)
    Snijders, Thom E.
    Schlosser, Tom P. C.
    van Straalen, Marijn
    Castelein, Rene M.
    Stevenson, Rob P.
    Weinans, Harrie
    de Gast, Arthur
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (08) : 1878 - 1879
  • [38] Validation of a CT image based software for three-dimensional measurement of acetabular cup orientation
    Wassilew, Georgi I.
    Janz, Viktor
    Heller, Markus
    Wenzl, Marcus
    Perka, Carsten
    Hasart, Olaf
    TECHNOLOGY AND HEALTH CARE, 2011, 19 (03) : 185 - 193
  • [39] Measurements of pelvic flexion angle using three-dimensional computed tomography
    Nishihara, S
    Sugano, N
    Nishii, T
    Ohzono, K
    Yoshikawa, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (411) : 140 - 151
  • [40] Three-fin acetabular prosthesis for superior acetabular bone defects: a three-dimensional finite element analysis
    Liu Yu-zeng
    Hai Yong
    Zhao Hui
    CHINESE MEDICAL JOURNAL, 2012, 125 (05) : 901 - 905