Detection of capripoxvirus DNA using a novel loop-mediated isothermal amplification assay

被引:26
|
作者
Murray, Lee [1 ]
Edwards, Lorraine [1 ]
Tuppurainen, Eeva S. M. [1 ]
Bachanek-Bankowska, Katarzyna [1 ]
Oura, Chris A. L. [1 ]
Mioulet, Valerie [1 ]
King, Donald P. [1 ]
机构
[1] Pirbright Inst, Woking GU24 0NF, Surrey, England
关键词
Capripoxvirus; Diagnostics; Isothermal amplification; Field tests; LUMPY SKIN-DISEASE; RAPID DETECTION; REVERSE-TRANSCRIPTION; BIOPSY SAMPLES; PCR ASSAY; VIRUS; SHEEP;
D O I
10.1186/1746-6148-9-90
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: Sheep poxvirus (SPPV), Goat poxvirus (GTPV) and Lumpy skin disease virus (LSDV) are the most serious poxviruses of ruminants. They are double stranded DNA viruses of the genus Capripoxvirus, (subfamily Chordopoxvirinae) within the family Poxviridae. The aim of this study was to develop a Loop-mediated isothermal AMPlification (LAMP) assay for the detection of Capripoxvirus (CaPV) DNA. Results: A single LAMP assay targeting a conserved region of the CaPV P32 gene was selected from 3 pilot LAMP assays and optimised by adding loop primers to accelerate the reaction time. This LAMP assay successfully detected DNA prepared from representative CaPV isolates (SPPV, GTPV and LSDV), and did not cross-react with DNA extracted from other mammalian poxviruses. The analytical sensitivity of the LAMP assay was determined to be at least 163 DNA copies/mu l which is equivalent to the performance reported for diagnostic real-time PCR currently used for the detection of CaPV. LAMP reactions were monitored with an intercalating dye using a real-time PCR machine, or by agarose-gel electrophoresis. Furthermore, dual labelled LAMP products (generated using internal LAMP primers that were conjugated with either biotin or fluorescein) could be readily visualised using a lateral-flow device. Conclusions: This study provides a simple and rapid approach to detect CaPV DNA that may have utility for use in the field, or in non-specialised laboratories where expensive equipment is not available.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Rapid detection of Colletotrichum gloeosporioides using a loop-mediated isothermal amplification assay
    Wang, Shuaishuai
    Ye, Wenwu
    Tian, Qing
    Dong, Suomeng
    Zheng, Xiaobo
    AUSTRALASIAN PLANT PATHOLOGY, 2017, 46 (05) : 493 - 498
  • [12] A novel and rapid loop-mediated isothermal amplification assay for the specific detection of Verticillium dahliae
    Moradi, A.
    Almasi, M. A.
    Jafary, H.
    Mercado-Blanco, J.
    JOURNAL OF APPLIED MICROBIOLOGY, 2014, 116 (04) : 942 - 954
  • [13] Detection of phytoplasma by loop-mediated isothermal amplification of DNA (LAMP)
    Obura, E.
    Masiga, D.
    Wachira, F.
    Gurja, B.
    Khan, Z. R.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2011, 84 (02) : 312 - 316
  • [14] Development and validation of a novel detection method for Rickettsia rickettsii using a loop-mediated isothermal amplification assay
    Carvajal-Gamez, Bertha I.
    Olguin-Barrera, Aida
    Tinoco-Gracia, Luis
    Gordillo-Perez, Guadalupe
    Dzul-Rosado, Karla
    Aguilar-Tipacamu, Gabriela
    Hidalgo-Ruiz, Mario
    Mosqueda, Juan
    FRONTIERS IN MICROBIOLOGY, 2024, 14
  • [15] Rapid screening method for male DNA by using the loop-mediated isothermal amplification assay
    Masashi Kitamura
    Seiji Kubo
    Jin Tanaka
    Tatsushi Adachi
    International Journal of Legal Medicine, 2018, 132 : 975 - 981
  • [16] Rapid screening method for male DNA by using the loop-mediated isothermal amplification assay
    Kitamura, Masashi
    Kubo, Seiji
    Tanaka, Jin
    Adachi, Tatsushi
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2018, 132 (04) : 975 - 981
  • [17] Rapid detection of Mycoplasma pneumoniae by loop-mediated isothermal amplification assay
    Yuan, Xin
    Bai, Changqing
    Cui, Qian
    Zhang, Han
    Yuan, Jing
    Niu, Kaiwen
    Feng, Yuzhong
    Jin, Xin
    Li, Puyuan
    Liu, Huiying
    MEDICINE, 2018, 97 (25)
  • [18] Development of Loop-Mediated Isothermal Amplification Assay for Detection of Entamoeba histolytica
    Liang, Shih-Yu
    Chan, Yun-Hsien
    Hsia, Kan-Tai
    Lee, Jing-Lun
    Kuo, Ming-Chu
    Hwa, Kuo-Yuan
    Chan, Chi-Wen
    Chiang, Ting-Yi
    Chen, Jung-Sheng
    Wu, Fang-Tzy
    Ji, Dar-Der
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (06) : 1892 - 1895
  • [19] Development of a loop-mediated isothermal amplification assay for the detection of porcine hokovirus
    Li, Bin
    Sun, Bing
    Du, Lu-ping
    Mao, Ai-hua
    Wen, Li-bin
    Ni, Yan-xiu
    Zhang, Xue-han
    He, Kong-wang
    JOURNAL OF VIROLOGICAL METHODS, 2013, 193 (02) : 415 - 418
  • [20] A loop-mediated isothermal amplification assay for the visual detection of duck circovirus
    Xie, Liji
    Xie, Zhixun
    Zhao, Guangyuan
    Liu, Jiabo
    Pang, Yaoshan
    Deng, Xianwen
    Xie, Zhiqin
    Fan, Qing
    Luo, Sisi
    VIROLOGY JOURNAL, 2014, 11