Impact of Posterior Corneal Surface on Toric Intraocular Lens (IOL) Calculation

被引:38
|
作者
Preussner, Paul-Rolf [1 ]
Hoffmann, Peter [2 ]
Wahl, Jochen [1 ]
机构
[1] Univ Eye Hosp, D-55101 Mainz, Germany
[2] Private Eye Clin, Castrop Rauxel, Germany
关键词
Astigmatism; keratoconus; posterior corneal surface; toric IOL calculation; vector differences; ASTIGMATISM; ANTERIOR; POWER; REPEATABILITY; SHAPE; TOMOGRAPHY; ABERRATION; CURVATURE; ACCURACY;
D O I
10.3109/02713683.2014.959708
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To quantify the impact of posterior cornea on toric IOL calculation accuracy using Placido-topography of anterior corneal surface and Scheimpflug measurements of corneal thickness. Materials and Methods: Three-hundred seventy-nine non-selected eyes undergoing cataract surgery with non-toric intraocular lens (IOL) implantation were measured with TMS-5 (Tomey, Japan), IOLMaster (Zeiss, Germany) and Lenstar (Haag-Streit, Switzerland). Anterior, posterior and total measured corneal astigmatisms were compared with astigmatisms from postoperative refraction by calculating vector differences. Results: The average absolute vector difference between anterior astigmatism and total astigmatism combining the measurements of anterior and posterior cornea was only 0.3 +/- 0.2 D, with a median of only 0.27 D, but a maximum of 1.5 D. Measurements of anterior cornea alone show a systematic difference from refractive cylinder of 0.3-6 D at 90, 0.38 D at 89 degrees and 0.28 D at 91 degrees (IOLMaster, Lenstar and anterior TMS5), whereas the total TMS5 cylinder differs on average by only 0.14D at 81 degrees from the refractive cylinder. With-the-rule (WTR) corneal astigmatism is slightly reduced and against-the-rule (ATR) astigmatism slightly increased on average when posterior corneal surface is taken into account additionally. This could also be confirmed by the calculation of an average pachymetry of all eyes in which the thinnest central part shows an ellipsoidal shape with horizontally long axis. Conclusion: Measurements of posterior cornea have on average only a small but significant impact on the outcome of toric IOL calculation, however, they are nevertheless recommended to detect outliers in which corneal irregularities (e.g. beginning keratokonus) may be overlooked.
引用
收藏
页码:809 / 814
页数:6
相关论文
共 50 条
  • [41] Effect of corneal marking features on toric intraocular lens alignment
    Hasan Aytogan
    [J]. International Ophthalmology, 2020, 40 : 1653 - 1658
  • [42] Toric intraocular lens implantation in cataract patients with corneal opacity
    Ra, Ho
    Hwang, Ho Sik
    Kim, Hyun Seung
    Kim, Man Soo
    Kim, Eun Chul
    [J]. BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [43] The Effect of Corneal Astigmatism Orientation on Toric Intraocular Lens Outcome
    Lowry, Eugene Alan
    Kasi, Sundeep
    Naseri, Ayman
    Blumberg, Seth
    Moriaria, Priya
    Schallhorn, Steven C.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [44] Effects of the toric intraocular lens on correction of preexisting corneal astigmatism
    Hiroshi Sasaki
    Motoaki Yoshida
    Shin-ichi Manabe
    Koichi Yoshimura
    Ken Hayashi
    [J]. Japanese Journal of Ophthalmology, 2012, 56 : 445 - 452
  • [45] Toric intraocular lens implantation in cataract patients with corneal opacity
    Ho Ra
    Ho Sik Hwang
    Hyun Seung Kim
    Man Soo Kim
    Eun Chul Kim
    [J]. BMC Ophthalmology, 20
  • [46] Validation of Orbscan II posterior corneal curvature measurement for intraocular lens power calculation
    Leyland, M
    [J]. EYE, 2004, 18 (04) : 357 - 360
  • [47] An evaluation of the accuracy of toric intraocular lens power calculation based on measured total corneal refractive power
    Yang, Zhi
    Zhou, Yanwen
    Jin, Tianru
    Li, Jingjing
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (02) : 541 - 546
  • [48] Validation of Orbscan II posterior corneal curvature measurement for intraocular lens power calculation
    M Leyland
    [J]. Eye, 2004, 18 : 357 - 360
  • [49] Assessing the Likely Effect of Posterior Corneal Curvature on Toric IOL Calculation for IOLs of 2.50 D or Greater Cylinder Power
    LaHood, Benjamin R.
    Goggin, Michael
    Esterman, Adrian
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (11) : 730 - 735
  • [50] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Jingyi Shi
    Zehui Zhu
    Bin Hu
    Shuyi Qian
    Yalan Wang
    Pingjun Chang
    Yun-e Zhao
    [J]. Ophthalmology and Therapy, 2024, 13 : 1321 - 1342