Impact of Posterior Corneal Surface on Toric Intraocular Lens (IOL) Calculation

被引:38
|
作者
Preussner, Paul-Rolf [1 ]
Hoffmann, Peter [2 ]
Wahl, Jochen [1 ]
机构
[1] Univ Eye Hosp, D-55101 Mainz, Germany
[2] Private Eye Clin, Castrop Rauxel, Germany
关键词
Astigmatism; keratoconus; posterior corneal surface; toric IOL calculation; vector differences; ASTIGMATISM; ANTERIOR; POWER; REPEATABILITY; SHAPE; TOMOGRAPHY; ABERRATION; CURVATURE; ACCURACY;
D O I
10.3109/02713683.2014.959708
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To quantify the impact of posterior cornea on toric IOL calculation accuracy using Placido-topography of anterior corneal surface and Scheimpflug measurements of corneal thickness. Materials and Methods: Three-hundred seventy-nine non-selected eyes undergoing cataract surgery with non-toric intraocular lens (IOL) implantation were measured with TMS-5 (Tomey, Japan), IOLMaster (Zeiss, Germany) and Lenstar (Haag-Streit, Switzerland). Anterior, posterior and total measured corneal astigmatisms were compared with astigmatisms from postoperative refraction by calculating vector differences. Results: The average absolute vector difference between anterior astigmatism and total astigmatism combining the measurements of anterior and posterior cornea was only 0.3 +/- 0.2 D, with a median of only 0.27 D, but a maximum of 1.5 D. Measurements of anterior cornea alone show a systematic difference from refractive cylinder of 0.3-6 D at 90, 0.38 D at 89 degrees and 0.28 D at 91 degrees (IOLMaster, Lenstar and anterior TMS5), whereas the total TMS5 cylinder differs on average by only 0.14D at 81 degrees from the refractive cylinder. With-the-rule (WTR) corneal astigmatism is slightly reduced and against-the-rule (ATR) astigmatism slightly increased on average when posterior corneal surface is taken into account additionally. This could also be confirmed by the calculation of an average pachymetry of all eyes in which the thinnest central part shows an ellipsoidal shape with horizontally long axis. Conclusion: Measurements of posterior cornea have on average only a small but significant impact on the outcome of toric IOL calculation, however, they are nevertheless recommended to detect outliers in which corneal irregularities (e.g. beginning keratokonus) may be overlooked.
引用
收藏
页码:809 / 814
页数:6
相关论文
共 50 条
  • [21] Clinical differences between toric intraocular lens (IOL) and monofocal intraocular lens (IOL) implantation when myopia is determined as target refraction
    Shin, Da Young
    Hwang, Ho Sik
    Kim, Hyun Seung
    Kim, Man Soo
    Kim, Eun Chul
    [J]. BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [22] Clinical differences between toric intraocular lens (IOL) and monofocal intraocular lens (IOL) implantation when myopia is determined as target refraction
    Da Young Shin
    Ho Sik Hwang
    Hyun Seung Kim
    Man Soo Kim
    Eun Chul Kim
    [J]. BMC Ophthalmology, 21
  • [23] Toric intraocular lens outcomes with a new protocol for IOL selection and implantation
    Clark, K. D.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2018, 41 (02): : 145 - 151
  • [24] |Accuracy of toric intraocular lens calculations using estimated versus measured posterior corneal astigmatism
    Segers, M. H. M.
    Abulafia, A.
    Webers, V. S. C.
    Verstraaten, J. -W.
    Vandevenne, M. M. S.
    Berendschot, T. T. J. M.
    Barrett, G. D.
    Nuijts, R. M. M. A.
    Dickman, M. M.
    [J]. ACTA OPHTHALMOLOGICA, 2023, 101 : 6 - 6
  • [25] Influence of posterior corneal astigmatism on the outcomes of toric intraocular lens implantation in eyes with oblique astigmatism
    Nakano, Shinichiro
    Iida, Masaharu
    Hasegawa, Yumi
    Hiraoka, Takahiro
    Oshika, Tetsuro
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2021, 65 (02) : 288 - 294
  • [26] Influence of posterior corneal astigmatism on the outcomes of toric intraocular lens implantation in eyes with oblique astigmatism
    Shinichiro Nakano
    Masaharu Iida
    Yumi Hasegawa
    Takahiro Hiraoka
    Tetsuro Oshika
    [J]. Japanese Journal of Ophthalmology, 2021, 65 : 288 - 294
  • [27] Reply: Predicted vs measured posterior corneal astigmatism for toric intraocular lens calculations.
    Shammas, H. John
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (10): : 1228 - 1229
  • [28] Accuracy of Toric Intraocular Lens Calculations Using Estimated Versus Measured Posterior Corneal Astigmatism
    Segers, Maartje H. M.
    Abulafia, Adi
    Webers, Valentijn S. C.
    Verstraaten, Jan-Willem
    Vandevenne, Magali M. S.
    Berendschot, Tos T. J. M.
    Kan-Tor, Yoav
    Benjamini, Yuval
    Van Den Biggelaar, Frank J. H. M.
    Barrett, Graham D.
    Nuijts, Rudy M. M. A.
    Dickman, Mor M.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 262 : 107 - 113
  • [29] Effects of Calculator with Posterior Corneal Astigmatism on Toric Intraocular Lens Selection and Simulated Residual Astigmatism
    Hasegawa, Yumi
    Hiraoka, Takahiro
    Seki, Mariko
    Nakano, Shinichiro
    Oshika, Tetsuro
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [30] Visual and autorefraction outcomes following toric intraocular lens insertion without calculation of posterior corneal astigmatism in the UK National Health Service
    Alasdair Warwick
    Alastair Porteous
    Valerie P. J. Saw
    [J]. Eye, 2020, 34 : 2082 - 2088