Glaucomatous damage patterns by short-wavelength automated perimetry (SWAP) in glaucoma suspects

被引:3
|
作者
Polo, V [1 ]
Larrosa, JM [1 ]
Pinilla, I [1 ]
Gonzalvo, F [1 ]
Ferreras, A [1 ]
Honrubia, FM [1 ]
机构
[1] Univ Zaragoza, Hosp Miguel Servet, Dept Ophthalmol, Zaragoza, Spain
关键词
short-wavelength automated perimetry; damage pattern; glaucoma; diagnosis;
D O I
10.1177/112067210201200110
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine the glaucomatous visual field damage patterns by short-wavelength automated perimetry (SWAP) in glaucoma suspects, and to compare the frequency of diffuse visual field losses and localized defects. METHODS. 157 eyes of 157 ocular hypertensive subjects who met the selection criteria (intraocular pressure greater than 21 mm Hg and normal standard visual fields) were studied. SWAP was done with a modified Humphrey Field Analyzer. Total (TD) and Pattern Deviation (PD) probability maps were calculated for SWAP. The frequency of abnormlities in the TD and PD were determined, analyzing the visual field loss components. RESULTS. The involvement Of the test points was more frequent on the TD plots than on the PD plots for all levels of defects (p< 0.001). The glaucomatous defects also showed certain topographical distribution. CONCLUSIONS. A diffuse sensitivity, component Of visual field loss was found at all SWAP defect depths in glaucoma suspects.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 50 条
  • [41] Short-wavelength automated perimetry and retinal nerve fiber layer evaluation in suspected cases of glaucoma
    Polo, V
    Abecia, E
    Pablo, LE
    Pinilla, I
    Larrosa, JM
    Honrubia, FM
    ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (10) : 1295 - 1298
  • [42] Standard achromatic perimetry, short wavelength automated perimetry, and frequency doubling technology for detection of glaucoma damage
    Soliman, MAE
    de Jong, LAMS
    Ismaeil, AA
    van den Berg, TJTP
    de Smet, MD
    OPHTHALMOLOGY, 2002, 109 (03) : 444 - 454
  • [43] Detection of early visual field loss in glaucoma using frequency-doubling perimetry and short-wavelength automated perimetry
    Landers, JA
    Goldberg, I
    Graham, SL
    ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (12) : 1705 - 1710
  • [44] New rapid threshold algorithm for short-wavelength automated perimetry
    Bengtsson, B
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (03) : 1388 - 1394
  • [45] SHORT-WAVELENGTH AUTOMATED PERIMETRY (SWAP) IN LOW, MEDIUM AND HIGH-RISK OCULAR HYPERTENSIVES - INITIAL RESULTS
    JOHNSON, CA
    BRANDT, JD
    KHONG, AM
    ADAMS, AJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2188 - 2188
  • [46] Development of a maximum likelihood procedure for short-wavelength automated perimetry
    Turpin, A
    Johnson, CA
    Spry, PGD
    PERIMETRY UPDATE 2000/2001, 2001, : 139 - 147
  • [47] Short-wavelength automated perimetry in normal subjects - Prelimiary results
    Mojon, DS
    Zulauf, M
    PERIMETRY UPDATE 2002/2003, 2004, : 245 - 245
  • [48] SHORT-WAVELENGTH AUTOMATED PERIMETRY WITHOUT LENS DENSITY TESTING
    SAMPLE, PA
    MARTINEZ, GA
    WEINREB, RN
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (05) : 632 - 641
  • [49] SHORT-WAVELENGTH COLOR VISUAL-FIELDS IN GLAUCOMA SUSPECTS AT RISK
    SAMPLE, PA
    TAYLOR, JDN
    MARTINEZ, GA
    LUSKY, M
    WEINREB, RN
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 115 (02) : 225 - 233
  • [50] The influences of stimulus wavelength and eccentricity on short-wavelength pathway isolation in automated perimetry
    Cubbidge, RP
    Wild, JM
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2001, 21 (01) : 1 - 8