Glaucomatous damage patterns by short-wavelength automated perimetry (SWAP) in glaucoma suspects

被引:3
|
作者
Polo, V [1 ]
Larrosa, JM [1 ]
Pinilla, I [1 ]
Gonzalvo, F [1 ]
Ferreras, A [1 ]
Honrubia, FM [1 ]
机构
[1] Univ Zaragoza, Hosp Miguel Servet, Dept Ophthalmol, Zaragoza, Spain
关键词
short-wavelength automated perimetry; damage pattern; glaucoma; diagnosis;
D O I
10.1177/112067210201200110
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine the glaucomatous visual field damage patterns by short-wavelength automated perimetry (SWAP) in glaucoma suspects, and to compare the frequency of diffuse visual field losses and localized defects. METHODS. 157 eyes of 157 ocular hypertensive subjects who met the selection criteria (intraocular pressure greater than 21 mm Hg and normal standard visual fields) were studied. SWAP was done with a modified Humphrey Field Analyzer. Total (TD) and Pattern Deviation (PD) probability maps were calculated for SWAP. The frequency of abnormlities in the TD and PD were determined, analyzing the visual field loss components. RESULTS. The involvement Of the test points was more frequent on the TD plots than on the PD plots for all levels of defects (p< 0.001). The glaucomatous defects also showed certain topographical distribution. CONCLUSIONS. A diffuse sensitivity, component Of visual field loss was found at all SWAP defect depths in glaucoma suspects.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 50 条
  • [31] Intersession variability of short-wavelength automated perimetry
    Remky, A
    Arend, O
    OPHTHALMOLOGE, 2000, 97 (11): : 774 - 780
  • [32] Short-wavelength automated perimetry:: Abnormality criteria
    Polo, V
    Larrosa, JM
    Pinilla, I
    Pablo, L
    Fernández, FJ
    Honrubia, FM
    ANNALS OF OPHTHALMOLOGY, 2002, 34 (01) : 30 - 33
  • [33] SHORT-WAVELENGTH AUTOMATED PERIMETRY IN NEUROOPHTHALMOLOGICAL DISORDERS
    KELTNER, JL
    JOHNSON, CA
    ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (04) : 475 - 481
  • [34] Short-wavelength automated perimetry in patients with migraine
    Yenice, Ozlem
    Temel, Ahmet
    Incili, Burcin
    Tuncer, Nese
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (05) : 589 - 595
  • [35] Evaluation of the Optic Nerve Function in Early Glaucoma Diagnosis. Standard Automated Perimetry (SAP), Short-Wavelength Automated Perimetry (SWAP), Frequency Doubling Technology (FDA, Pattern Electroretinogram (PERG) and Visual Evoked Potential (VEP) in Glaucoma Suspects
    Milano, G.
    Colombo, M.
    Bossolesi, L.
    Raimondi, M.
    Lanteri, S.
    Giardullo, A.
    Bordin, M.
    Rossi, G. C. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [36] Asymmetries in the normal short-wavelength visual field: Implications for short-wavelength automated perimetry
    Sample, PA
    Irak, I
    Martinez, GA
    Yamagishi, N
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (01) : 46 - 52
  • [37] Follow-up of patients at risk for glaucoma with Short-Wavelength-Automated-Perimetry (SWAP)
    Millano, G
    Rossi, GCM
    Guasconi, A
    Veneziano, F
    Stella, D
    Ruberto, G
    Trimarchi, F
    VISION RESEARCH, 1996, 36 : 25 - 25
  • [38] Evidence for a learning effect in short-wavelength automated perimetry
    Wild, JM
    Kim, LS
    Pacey, IE
    Cunliffe, IA
    OPHTHALMOLOGY, 2006, 113 (02) : 206 - 215
  • [39] Short-wavelength automated perimetry and neuroretinal rim area
    Larrosa, JM
    Polo, V
    Pablo, L
    Pinilla, I
    Fernandez, FJ
    Honrubia, P
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2000, 10 (02) : 116 - 120
  • [40] Retinal nerve fiber layer measurement by optical coherence tomography in glaucoma suspects with short-wavelength perimetry abnormalities
    Mok, KH
    Lee, VWH
    So, KF
    JOURNAL OF GLAUCOMA, 2003, 12 (01) : 45 - 49