Energy performance analysis of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector under the Mediterranean climate conditions

被引:47
|
作者
Maraj, Altin [1 ]
Londo, Andonaq [1 ]
Gebremedhin, Alemayehu [2 ]
Firat, Coskun [3 ]
机构
[1] Polytech Univ Tirana, Fac Mech Engn, Dept Energy, Tirana, Albania
[2] Norwegian Univ Sci & Technol, Dept Mfg & Civil Engn, Trondheim, Norway
[3] Tech Univ Istanbul, Energy Inst, Istanbul, Turkey
关键词
Forced circulation; Heat pipe; Useful energy gain; Collector efficiency; System efficiency; Solar fraction; THERMAL PERFORMANCE; FLAT-PLATE; EFFICIENCY; HOUSE;
D O I
10.1016/j.renene.2019.03.109
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work represents the energy performance analysis during the annual time period of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector having an aperture area of 1.476 m(2) under the Mediterranean climate conditions. For the purpose, recorded data from a field-trial installation are exploited. The recorded data obtained every minute are used to perform the energy analysis during an annual period. The analysis is performed by using mathematical models and by representing the results for each month. Monthly values of measured parameters and calculated quantities offered a clear view regarding the operation of the considered field-trial installation for this climate region. For an annual irradiation on solar collector plane of 2,212 kWh/year, it was noticed that the annual useful heat gain for the heat pipe evacuated solar tube collector, the useful energy delivered by the solar circuit to the storage tank, and the delivered energy to the thermal consumer were 1,345 kWh/year, 1,311 kWh/year, and 1,009 kWh/year, respectively. The annual efficiency for the heat pipe evacuated solar tube collector was 0.62, while for the forced circulated system was 0.516. Also, the annual energy balance of the system obtained from the calculation is built. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:874 / 883
页数:10
相关论文
共 50 条
  • [41] Thermal performance of phase change material integrated heat pipe evacuated tube solar collector system: An experimental assessment
    Chopra, K.
    Pathak, Atin K.
    Tyagi, V. V.
    Pandey, A. K.
    Anand, Sanjeev
    Sari, Ahmet
    ENERGY CONVERSION AND MANAGEMENT, 2020, 203
  • [42] Heating Performance of Solar Heat Pump Heating System With Aluminum Tube Collector
    Wu Zhenkui
    Yang Peihong
    Jiang Hui
    Wei Yili
    Zhang Jihong
    Zhang Zilei
    Zhang Xiaoming
    IEEE ACCESS, 2021, 9 (09): : 26491 - 26501
  • [43] Performance analysis and comparison of concentrated evacuated tube heat pipe solar collectors
    Nkwetta, Dan Nchelatebe
    Smyth, Mervyn
    APPLIED ENERGY, 2012, 98 : 22 - 32
  • [44] Performance analysis of evacuated tubes with thermosyphon heat pipe solar collector integrated with compound parabolic concentrator under different operating conditions
    Govindasamy, Kumaresan
    Palanivel, Vijayakumar
    Meena, Radhey Shyam
    Muthusamy, Suresh
    Panchal, Hitesh
    Shah, Mohd. Asif
    Siddiqui, Md Irfanul Haque
    ENERGY EXPLORATION & EXPLOITATION, 2024, 42 (01) : 231 - 249
  • [45] Thermal performance of a heat-pipe evacuated-tube solar collector at high inlet temperatures
    Elsheniti, Mahmoud B.
    Kotb, Amr
    Elsamni, Osama
    APPLIED THERMAL ENGINEERING, 2019, 154 : 315 - 325
  • [46] Improving the performance of heat pipe embedded evacuated tube collector with nanofluids and auxiliary gas system
    Daghigh, Roonak
    Zandi, Pooya
    RENEWABLE ENERGY, 2019, 134 : 888 - 901
  • [47] Analysis of micro heat pipe array based evacuated tube solar water heater integrated with an energy storage system for improved thermal performance
    Tamuli, Bhaskar Ranjan
    Nath, Sujit
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 41
  • [48] Experimental testing on the performance of solar dryer equipped with evacuated tube collector, rock bed heat storage and reflectors
    Yematawu S.
    Tamrat B.
    Tarekegn D.
    Mulugeta H.
    Energy Reports, 2024, 12 : 453 - 471
  • [49] Thermal performance of a thermosyphon heat pipe evacuated tube solar collector using silver-water nanofluid for commercial applications
    Ozsoy, Ahmet
    Corumlu, Vahit
    RENEWABLE ENERGY, 2018, 122 : 26 - 34
  • [50] CFD modeling and evaluation the performance of a solar cabinet dryer equipped with evacuated tube solar collector and thermal storage system
    Iranmanesh, Masoud
    Akhijahani, Hadi Samimi
    Jahromi, Mohammad Saleh Barghi
    RENEWABLE ENERGY, 2020, 145 (145) : 1192 - 1213