Energy performance analysis of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector under the Mediterranean climate conditions

被引:47
|
作者
Maraj, Altin [1 ]
Londo, Andonaq [1 ]
Gebremedhin, Alemayehu [2 ]
Firat, Coskun [3 ]
机构
[1] Polytech Univ Tirana, Fac Mech Engn, Dept Energy, Tirana, Albania
[2] Norwegian Univ Sci & Technol, Dept Mfg & Civil Engn, Trondheim, Norway
[3] Tech Univ Istanbul, Energy Inst, Istanbul, Turkey
关键词
Forced circulation; Heat pipe; Useful energy gain; Collector efficiency; System efficiency; Solar fraction; THERMAL PERFORMANCE; FLAT-PLATE; EFFICIENCY; HOUSE;
D O I
10.1016/j.renene.2019.03.109
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work represents the energy performance analysis during the annual time period of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector having an aperture area of 1.476 m(2) under the Mediterranean climate conditions. For the purpose, recorded data from a field-trial installation are exploited. The recorded data obtained every minute are used to perform the energy analysis during an annual period. The analysis is performed by using mathematical models and by representing the results for each month. Monthly values of measured parameters and calculated quantities offered a clear view regarding the operation of the considered field-trial installation for this climate region. For an annual irradiation on solar collector plane of 2,212 kWh/year, it was noticed that the annual useful heat gain for the heat pipe evacuated solar tube collector, the useful energy delivered by the solar circuit to the storage tank, and the delivered energy to the thermal consumer were 1,345 kWh/year, 1,311 kWh/year, and 1,009 kWh/year, respectively. The annual efficiency for the heat pipe evacuated solar tube collector was 0.62, while for the forced circulated system was 0.516. Also, the annual energy balance of the system obtained from the calculation is built. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:874 / 883
页数:10
相关论文
共 50 条
  • [21] Performance analysis of evacuated tube solar collector for residential heating in Mongolia
    Purevdalai, E.
    Amarbayar, A.
    Akisawa, Atsushi
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2015, 2015, : 1120 - 1126
  • [22] PERFORMANCE ANALYSIS OF EVACUATED TUBE COLLECTOR BASED SOLAR HEAT FOR INDUSTRIAL PROCESS (SHIP) SYSTEM IN MALAYSIAN CLIMATE
    Akbar, Muhammad Ali
    Rashid, Muhammad Mahbubur
    Bin Embong, Abd Halim
    Mohideen, Ahmad Jazlan Bin Haja
    Akhter, Muhammad Naveed
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2022, 17 (04): : 2299 - 2314
  • [23] Energy, Exergy and Economic (3E) analysis of evacuated tube heat pipe solar collector to promote storage energy under North African climate
    Bouadila, Salwa
    Rehman, Tauseef-ur
    Baig, Maughal Ahmed Ali
    Skouri, Safa
    Baddadi, Sara
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2023, 55
  • [24] PERFORMANCE OF AN EVACUATED GLASS TUBE SOLAR COLLECTOR INTEGRATED WITH A SOLAR HEATING SYSTEM.
    Ward, John C.
    Ward, Dan S.
    1600, Am Sect of Int Sol Energy Soc, Inc, Univ of DelNewark (2 .):
  • [25] Energetic and exergetic analysis of a heat pipe evacuated tube solar collector using MWCNT/water nanofluid
    Eltaweel, Mahmoud
    Abdel-Rehim, Ahmed A.
    Attia, Ahmed A. A.
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 22
  • [26] Profitability of a solar water heating system with evacuated tube collector in the meat industry
    Luis Garcia, Jose
    Javier Porras-Prieto, Carlos
    Maria Benavente, Rosa
    Teresa Gomez-Villarino, Maria
    Mazarron, Fernando R.
    RENEWABLE ENERGY, 2019, 131 : 966 - 976
  • [27] Analysis of heat transfer characteristics for parabolic trough solar collector system with heat-pipe evacuated tube
    Zhang W.
    Wang J.
    Tian R.
    Xue Q.
    Ba X.
    2018, Chinese Society of Agricultural Engineering (34): : 202 - 209
  • [28] Experimental analysis of thermal performance according to heat pipe working fluids for evacuated tube solar collector
    Hong-Jin Joo
    Hee-Youl Kwak
    Heat and Mass Transfer, 2017, 53 : 3267 - 3275
  • [29] Experimental analysis of thermal performance according to heat pipe working fluids for evacuated tube solar collector
    Joo, Hong-Jin
    Kwak, Hee-Youl
    HEAT AND MASS TRANSFER, 2017, 53 (11) : 3267 - 3275
  • [30] Thermal performance of U-pipe evacuated tube solar collector with latent heat thermal energy storage
    Liu Y.
    Li T.
    Li Y.
    Chen Y.
    Wang D.
    Liu J.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (07): : 244 - 250