High intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI)

被引:25
|
作者
Han, Yang [1 ]
Hou, Gary Yi [1 ]
Wang, Shutao [1 ]
Konofagou, Elisa [1 ,2 ]
机构
[1] Columbia Univ, Dept Biomed Engn, New York, NY 10027 USA
[2] Columbia Univ, Dept Radiol, New York, NY 10027 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 15期
基金
美国国家卫生研究院;
关键词
HMIFU; HIFU; focal spot localization; ACOUSTIC RADIATION FORCE; DIAGNOSTIC ULTRASOUND; IN-VITRO; LIVER; ELASTOGRAPHY; FEASIBILITY; VALIDATION; DEPENDENCE; ABLATION; TISSUES;
D O I
10.1088/0031-9155/60/15/5911
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several ultrasound-based imaging modalities have been proposed for image guidance and monitoring of high-intensity focused ultrasound (HIFU) treatment. However, accurate localization and characterization of the effective region of treatment (focal spot) remain important obstacles in the clinical implementation of HIFU ablation. Harmonic motion imaging for focused ultrasound (HMIFU) is a HIFU monitoring technique that utilizes radiation-force-induced localized oscillatory displacement. HMIFU has been shown to correctly identify the formation and extent of HIFU thermal ablation lesions. However a significant problem remains in identifying the location of the HIFU focus, which is necessary for treatment planning. In this study, the induced displacement was employed to localize the HIFU focal spot inside the tissue prior to treatment. Feasibility was shown with two separate systems. The 1D HMIFU system consisted of a HIFU transducer emitting an amplitude-modulated HIFU beam for mechanical excitation and a confocal single-element, pulse-echo transducer for simultaneous RF acquisition. The 2D HIFU system consists of a HIFU phased array, and a co-axial imaging phased array for simultaneous imaging. Initial feasibility was first performed on tissue-mimicking gelatin phantoms and the focal zone was defined as the region corresponding to the -3dB full width at half maximum of the HMI displacement. Using the same parameters, in vitro experiments were performed in canine liver specimens to compare the defined focal zone with the lesion. In vitro measurements showed good agreement between the HMI predicted focal zone and the induced HIFU lesion location. HMIFU was experimentally shown to be capable of predicting and tracking the focal region in both phantoms and in vitro tissues. The accuracy of focal spot localization was evaluated by comparing with the lesion location in post-ablative tissues, with a R-2 = 0.821 at p < 0.002 in the 2D HMI system. We demonstrated the feasibility of using this HMI-based technique to localize the HIFU focal spot without inducing thermal changes during the planning phase. The focal spot localization method has also been applied on ex vivo human breast tissue ablation and can be fully integrated into any HMI system for planning purposes.
引用
收藏
页码:5911 / 5924
页数:14
相关论文
共 50 条
  • [41] Prospective multicentre study using high intensity focused ultrasound (HIFU) for the focal treatment of prostate cancer: Safety outcomes and complications
    Schmid, F. A.
    Schindele, D.
    Mortezavi, A.
    Spitznagel, T.
    Sulser, T.
    Schostak, M.
    Eberli, D.
    UROLOGIC ONCOLOGY-SEMINARS AND ORIGINAL INVESTIGATIONS, 2020, 38 (04) : 225 - 230
  • [42] Thermal ablation system using high intensity focused ultrasound (HIFU) and guided by MRI
    Damianou, C.
    Ioannides, K.
    HadjiSavas, V.
    Milonas, N.
    Couppis, A.
    Iosif, D.
    Komodromos, M.
    Vrionides, F.
    8TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2009, 1113 : 367 - +
  • [43] Theoretically Estimating the Acoustic Intensity of High-Intensity Focused Ultrasound (HIFU) Using Infrared Thermography
    Zhou, Yufeng
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (06) : 1159 - 1165
  • [44] The effect of Ultrasound cycloplasty (UCP) using High Intensity Focused Ultrasound (HiFU) on aqueous humor dynamics
    Alaghband, Pouya
    Galvis, Elizabeth Angela P.
    Madekurozwa, Michael
    Eslah, Esmail
    Chu, Brian
    Overby, Darryl R.
    Lim, K. Sheng
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [45] PREDICTORS OF TREATMENT FAILURE AFTER FOCAL HIGH-INTENSITY FOCUSED ULTRASOUND (HIFU) OF LOCALIZED PROSTATE CANCER
    Soerensen, Simon John Christoph
    Sommer, Elijah R.
    Zhou, Steve R.
    Rusu, Mirabela
    Fan, Richard E.
    Sonn, Geoffrey A.
    JOURNAL OF UROLOGY, 2024, 211 (05): : E411 - E412
  • [46] Optimization of Phase Shift of the Transducer for High Intensity Focused Ultrasound (HIFU)
    Yamamoto, Mariko
    Yoshizawa, Shin
    Umemura, Shin-ichiro
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1625 - 1628
  • [47] High intensity focused ultrasound (HIFU) for the treatment of symptomatic breast fibroadenoma
    Hahn, M.
    Fugunt, R.
    Schoenfisch, B.
    Oberlechner, E.
    Gruber, I. V.
    Hoopmann, U.
    Roehm, C.
    Helms, G.
    Taran, F. A.
    Hartkopf, A. D.
    Warzecha, H.
    Wiesinger, B.
    Brucker, S. Y.
    Boeer, B.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 35 (01) : 463 - 470
  • [48] FDA Regulation of Clinical High Intensity Focused Ultrasound (HIFU) Devices
    Harris, Gerald R.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 145 - 148
  • [49] High intensity focused ultrasound (HIFU) treatment of human pancreatic cancer
    Zaitsev, AV
    Sanghvi, NT
    Ikenberry, S
    Worzalla, JF
    Schultz, RM
    Self, TD
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 1295 - 1298
  • [50] High-intensity focused ultrasound (HIFU) therapy for pancreatic cancer
    Asai, Yasutsugu
    Sofuni, Atsushi
    Itoi, Takao
    Tsuchiya, Takayoshi
    Tsuji, Shujiro
    Kamada, Kentaro
    Tanaka, Reina
    Honjyou, Mitsuyoshi
    Mukai, Shuntaro
    Yamamoto, Kenjiro
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2016, 31 : 261 - 261