Image Based Contactless Blood Pressure Assessment using Pulse Transit Time

被引:0
|
作者
Huang, Po-Wei [1 ]
Lin, Chun-Hao [1 ]
Chung, Meng-Liang [2 ]
Lin, Tzu-Min [3 ]
Wu, Bing-Fei [2 ]
机构
[1] NCTU, Inst Elect & Control Engn, Hsinchu 300, Taiwan
[2] NCTU, Dept Elect & Comp Engn, Hsinchu, Taiwan
[3] Taipei Med Univ Hosp, Dept Internal Med, Div Rheumatol Immunol & Allergy, Taipei 110, Taiwan
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Recent years have seen increased attention being given to Blood Pressure (BP) monitoring. Among all kinds of measurements, the monitors based on Pulse Transit Time (PTT) have gain plenty of attention due to its continuous and cuffless features. Additionally, several studies proposed a fancy way to estimate photoplethysmography (PPG) signal simply via a regular webcam. Nevertheless, literatures on issues of integrating these two advanced techniques have emerged on a slowly and scattered way. Furthermore, accuracy of BP prediction model based on PTT is often limited due to the lack of data. To address the above-mentioned problems, we proposed an image based BP measurement algorithm using k-nearest neighbor and transfer learning results from MIMICII database to real task. The study also introduces newly defined PTT features which are especially suitable for image based PPG and domain adaptation. Compared with the state-of-the-art algorithm, root mean square error of SBP evaluation has been reduced from 15.08 to 14.02.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Pulse waveform as an indicator of baseline offset in pulse transit time based blood pressure estimation
    Lin, Chen
    Zhou, Yuan
    Wang, Hu
    Wang, Yao
    2017 IEEE-NIH HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT), 2017, : 26 - 31
  • [22] Continuous Systolic Blood Pressure Measurement Based on Improved Pulse Transit Time
    Xie, Meng
    Yang, Bo
    Chen, Cailian
    Guan, Xinping
    Hong, Peijun
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 5173 - 5178
  • [23] Non-contact Blood Pressure Measurement Based on Pulse Transit Time
    Chen Pengyong
    Zhou Zuofeng
    Zhao Ting
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [24] Contactless blood pressure assessment by facial visible image analysis
    Oiwa K.
    Bando S.
    Nozawa A.
    Oiwa, Kosuke (oiwa@ee.aoyama.ac.jp), 2018, Institute of Electrical Engineers of Japan (138) : 783 - 789
  • [25] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Heiko Gesche
    Detlef Grosskurth
    Gert Küchler
    Andreas Patzak
    European Journal of Applied Physiology, 2012, 112 : 309 - 315
  • [26] Pulse Transit Time-based Blood Pressure Estimation Using Hilbert-Huang Transform
    Zhang, Qiao
    Shi, Yang
    Teng, Daniel
    Dinh, Anh
    Ko, Seok-Bum
    Chen, Li
    Basran, Jenny
    Dal Bello-Haas, Vanina
    Choi, Younhee
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1785 - +
  • [27] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Gesche, Heiko
    Grosskurth, Detlef
    Kuechler, Gert
    Patzak, Andreas
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) : 309 - 315
  • [28] Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure
    Zhang, Guanqun
    Gao, Mingwu
    Xu, Da
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (06) : 1681 - 1686
  • [29] Robust contactless pulse transit time estimation based on signal quality metric
    Fan, Xijian
    Tjahjadi, Tardi
    PATTERN RECOGNITION LETTERS, 2020, 137 : 12 - 16
  • [30] Validation of ambulatory blood pressure monitoring and pulse transit time
    Liendo Martinez, K. H.
    Lopez-Padilla, D.
    De Miguel Diez, J.
    Villar Alvarez, F.
    Gomez Garcia, T.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60