Image Based Contactless Blood Pressure Assessment using Pulse Transit Time

被引:0
|
作者
Huang, Po-Wei [1 ]
Lin, Chun-Hao [1 ]
Chung, Meng-Liang [2 ]
Lin, Tzu-Min [3 ]
Wu, Bing-Fei [2 ]
机构
[1] NCTU, Inst Elect & Control Engn, Hsinchu 300, Taiwan
[2] NCTU, Dept Elect & Comp Engn, Hsinchu, Taiwan
[3] Taipei Med Univ Hosp, Dept Internal Med, Div Rheumatol Immunol & Allergy, Taipei 110, Taiwan
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Recent years have seen increased attention being given to Blood Pressure (BP) monitoring. Among all kinds of measurements, the monitors based on Pulse Transit Time (PTT) have gain plenty of attention due to its continuous and cuffless features. Additionally, several studies proposed a fancy way to estimate photoplethysmography (PPG) signal simply via a regular webcam. Nevertheless, literatures on issues of integrating these two advanced techniques have emerged on a slowly and scattered way. Furthermore, accuracy of BP prediction model based on PTT is often limited due to the lack of data. To address the above-mentioned problems, we proposed an image based BP measurement algorithm using k-nearest neighbor and transfer learning results from MIMICII database to real task. The study also introduces newly defined PTT features which are especially suitable for image based PPG and domain adaptation. Compared with the state-of-the-art algorithm, root mean square error of SBP evaluation has been reduced from 15.08 to 14.02.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] Using the changes in hydrostatic pressure and pulse transit time to measure arterial blood pressure
    Poon, Carmen C. Y.
    Zhang, Y. T.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2336 - 2337
  • [12] Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference
    Gao, Mingwu
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    PHYSIOLOGICAL REPORTS, 2016, 4 (10):
  • [13] EFFECTS OF SKIN TONE AND AMBIENT LIGHTING ON ACCURACY OF CONTACTLESS MEASUREMENT OF HEART RATE AND PULSE TRANSIT TIME: AN INVESTIGATION TOWARD IMAGE-BASED BLOOD PRESSURE ESTIMATION
    Shirbani, Fatemeh
    Hui, Tsz Him
    Tan, Isabella
    Butlin, Mark
    Avolio, Alberto
    JOURNAL OF HYPERTENSION, 2021, 39 : E128 - E129
  • [14] Perturbationless Calibration of Pulse Transit Time to Blood Pressure
    Gao, Mingwu
    Mukkamala, Ramakrishna
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 232 - 235
  • [15] Limitation of Pulse Transit Time to Estimate Blood Pressure
    Sklarsky, Amanda
    Garvin, Nathan M.
    Pawelczyk, James A.
    FASEB JOURNAL, 2019, 33
  • [16] Continuous blood pressure measurement based on pulse transit time: a comparison to ambulatory blood pressure measurement
    Kuechler, G.
    Gehring, J.
    Wesely, M.
    Thimel, K.
    Haberl, R.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1267 - 1267
  • [17] Towards Ubiquitous Blood Pressure Monitoring in an Armband using Pulse Transit Time
    Toreyin, Hakan
    Javaid, Abdul Q.
    Ashouri, Hazar
    Ode, Oludotun
    Inan, Omer T.
    2015 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2015, : 560 - 563
  • [18] Adaptive Algorithm for Continuous Monitoring of Blood Pressure Using a Pulse Transit Time
    Jadooei, Ali
    Zaderykhin, O.
    Shulgin, V. I.
    2013 IEEE XXXIII INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2013, : 297 - 301
  • [19] Blood Pressure Assessment with Differential Pulse Transit Time and Deep Learning: A Proof of Concept
    Ribas Ripoll, Vicent
    Vellido, Alfredo
    KIDNEY DISEASES, 2019, 5 (01) : 23 - 27
  • [20] VALIDATION OF THE FREESCAN PULSE TRANSIT TIME-BASED BLOOD PRESSURE MONITOR
    Wu, Chih-Cheng
    Chao, Paul C. -P.
    JOURNAL OF HYPERTENSION, 2016, 34 : E142 - E142