Evaluation of inhomogeneity correction factors for 6 MV flattening filter-free beams with brass compensators

被引:2
|
作者
Robinson, Joshua [1 ,2 ]
Opp, Daniel [1 ]
Zhang, Geoffrey [1 ]
Feygelman, Vladimir [1 ]
机构
[1] H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL 33612 USA
[2] Univ S Florida, Dept Phys, Tampa, FL 33620 USA
来源
关键词
flattening filter-free; compensator; inhomogeneity correction factor; dose calculation accuracy; lung; MANAGEMENT; ACCURACY; DELIVERY; MOTION;
D O I
10.1120/jacmp.v14i3.3990
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The 6 MV flattening filter-free (FFF) beam has been commissioned for use with compensators at our institution. This novel combination promises advantages in mitigating tumor motion due to the reduced treatment time made possible by the greatly increased dose rate of the FFF beam. Given the different energy spectrum of the FFF beam and the beam hardening effect of the compensator, the accuracy of the treatment planning system (TPS) model in the presence of low-density heterogeneities cannot be assumed. Therefore, inhomogeneity correction factors (ICF) for an FFF beam attenuated by brass slabs were measured and compared to the TPS calculations in this work. The ICF is the ratio of the point dose in the presence of inhomogeneity to the dose in the same point in a homogeneous medium. The ICFs were measured with an ion chamber at a number of points in a flat water-equivalent slab phantom containing a 7.5 cm deep heterogeneity (air or 0.27 g/cm(3) wood). Comparisons for the FFF beam were carried out for the field sizes from 5 x 5 to 20 x 20 cm(2) with the brass slabs ranging from 0 to 5 cm in thickness. For a low-density wood heterogeneity in a slab phantom, with the exception of the point 1 cm beyond the proximal buildup interface, the TPS handles the inhomogeneity correction with the brass-filtered 6 MV FFF beam at the requisite 2% error level. The combinations of field sizes and compensator thicknesses when the error exceeds 2% (2.6% maximum) are not likely to be experienced in clinical practice. In terms of heterogeneity corrections, the beam model is adequate for clinical use.
引用
收藏
页码:226 / 231
页数:6
相关论文
共 50 条
  • [31] A Fast Adaptive Replanning Method for VMAT Using Flattening Filter-Free Beams
    Ates, O.
    Ahunbay, E. E.
    Moreau, M.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : S31 - S31
  • [32] Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening filter-free 7 MV beam line
    Sadrollahi, Alemeh
    Nuesken, Frank
    Licht, Norbert
    Ruebe, Christian
    Dzierma, Yvonne
    PLOS ONE, 2019, 14 (01):
  • [33] Output factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery system
    Cheng, Jason Y.
    Ning, Holly
    Arora, Barbara C.
    Ying Zhuge
    Miller, Robert W.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 100 - 110
  • [34] Determination of small field output factors in 6 and 10 MV flattening filter free photon beams using various detectors
    Masanga, W.
    Tangboonduangjit, P.
    Khamfongkhruea, C.
    Tannanonta, C.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [35] DNA strand breaks based on Monte Carlo simulation in and around the Lipiodol with flattening filter and flattening filter-free photon beams
    Kawahara, Daisuke
    Saito, Akito
    Nakano, Hisashi
    Nagata, Yasushi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (03) : 392 - 400
  • [36] Breast Tangential Treatment Plan Using Flattening Filter-free Beams: A Planning Study
    Xie, J.
    Cao, J.
    Chen, W.
    Cui, Y.
    Galvin, J.
    Yu, Y.
    Xiao, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S867 - S867
  • [37] Impact of flattening filter-free beams on remaining volume at risk in lung cancer treatment
    Alfishawy, Mahmoud Mohamed
    Kany, Amr Ismail
    Elshahat, Khaled Mohamed
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (03) : 455 - 464
  • [38] Reirradiation of nasopharyngeal carcinoma focusing on volumetric modulated arcs with flattening filter-free beams
    Zhuang, M.
    Huang, L.
    Zhu, D.
    Peng, X.
    Lin, Z.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1052):
  • [39] Dose rate response of Digital Megavolt Imager detector for flattening filter-free beams
    Xu, Zhigang
    Kim, Jinkoo
    Han, James
    Hsia, An Ting
    Ryu, Samuel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 141 - 147
  • [40] Interplay Effect During Lung SBRT With VMAT Delivered by Flattening Filter-Free Beams
    Rao, M.
    Ye, J.
    Spiegel, J.
    Takamiya, R.
    Mehta, V. K.
    Wu, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S192 - S192