Discrepancy between mitral valve areas measured by two-dimensional planimetry and three-dimensional transoesophageal echocardiography in patients with mitral stenosis

被引:45
|
作者
Min, Sun-Yang
Song, Jong-Min [1 ]
Kim, Yun-Jeong
Park, Hong-Kyung
Seo, Mi-Ohk
Lee, Moo-Song [2 ]
Kim, Dae-Hee
Kang, Duk-Hyun
Song, Jae-Kwan
机构
[1] Univ Ulsan, Coll Med, Dept Cardiol, Asan Med Ctr,Div Cardiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Div Biostat, Seoul 138736, South Korea
关键词
REAL-TIME; TRANSTHORACIC ECHOCARDIOGRAPHY; RECOMMENDATIONS; QUANTIFICATION; ACCURATE;
D O I
10.1136/heartjnl-2012-302742
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To compare mitral valve area (MVA) measurements obtained by 2D transthoracic planimetry and 3D transoesophageal echocardiography (TOE) in patients with mitral stenosis (MS), and to determine the causes of discrepancies between the two techniques. Design Reliability and agreement study. Setting Tertiary referral centre. Patients Eighty-seven patients with MS. Methods MVA was determined by transthoracic 2D planimetry and 3D TOE. Clinical and echocardiographic variables were evaluated. The angle (M alpha) between the lines of the true mitral valve (MV) tip and the echo beam-to-MV tip was measured at early diastole from the parasternal long-axis view obtained from 2D echocardiography. Results Although MVA measurements using 2D planimetry and 3D TOE showed good agreement (intraclass correlation coefficient, 0.853; p<0.001), 2D planimetry overestimated MVA by 0.19 +/- 0.2 cm(2) compared with 3D TOE (p<0.001). Left atrial (LA) dimension obtained from the parasternal long-axis view at end-systole (p=0.012), M alpha (p<0.001), and left ventricular ejection fraction (p=0.022) were independent determinants of the MVA difference (MVA by 2D-MVA by 3D TOE; MVA2D-3D) according to multiple linear regression analysis. The LA dimensions correlated with M alpha (r=0.352, p=0.001). The best cut-off values for predicting significant overestimation by 2D planimetry (MVA2D-3D>0.2 cm(2)) were LA dimension >= 49 mm (78% sensitivity, 72% specificity) and M alpha >= 9.5 degrees (56% sensitivity, 89% specificity). Conclusions Because 2D planimetry tends to overestimate MVA, 3D TOE should be considered for accurate MVA assessment, especially in patients with a large LA and large M alpha.
引用
收藏
页码:253 / 258
页数:6
相关论文
共 50 条
  • [31] Recognition of a cleft mitral valve utilizing real-time three-dimensional transoesophageal echocardiography
    Nomoto, Koichi
    Hollinger, Ingrid
    DiLuozzo, Gabriele
    Fischer, Gregory W.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (02): : 367 - 369
  • [32] Modeling the Myxomatous Mitral Valve With Three-Dimensional Echocardiography
    Pouch, Alison M.
    Jackson, Benjamin M.
    Lai, Eric
    Takebe, Manabu
    Tian, Sijie
    Cheung, Albert T.
    Woo, Y. Joseph
    Patel, Prakash A.
    Wang, Hongzhi
    Yushkevich, Paul A.
    Gorman, Robert C.
    Gorman, Joseph H., III
    ANNALS OF THORACIC SURGERY, 2016, 102 (03): : 703 - 711
  • [33] Acute effect of MitraClip implantation on mitral valve geometry in patients with functional mitral regurgitation: insights from three-dimensional transoesophageal echocardiography
    Al Amri, Ibtihal
    Debonnaire, Philippe
    van der Kley, Frank
    Schalij, Martin J.
    Bax, Jeroen J.
    Marsan, Nina Ajmone
    Delgado, Victoria
    EUROINTERVENTION, 2016, 11 (13) : 1554 - 1561
  • [34] Impact of Left Atrial Volume Index on Discrepancy in Mitral Valve Area Assessed by Two-Dimensional Planimetry and Three-Dimensional Multi-Planar Reconstruction Technique
    Toufan, Mehrnoush
    Jabbary, Zahra
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2021, 23 (08)
  • [35] Measurement of mitral valve area by direct three dimensional planimetry compared to multiplanar reconstruction in patients with rheumatic mitral stenosis
    Tabrizi, Mehrnoush Toufan
    Azad, Haniyeh Faraji
    Khezerlouy-Aghdam, Naser
    Sakha, Hanieh
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2022, 38 (06): : 1341 - 1349
  • [36] TWO-DIMENSIONAL ECHOCARDIOGRAPHY IN MITRAL-VALVE DISEASE
    LESBRE, JP
    SCHURTZ, C
    KALISA, A
    COURBETANDREJAK, MT
    GENUYT, L
    DELMAIRE, M
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1981, 74 (10): : 1163 - 1176
  • [37] Pitfalls of anatomical aortic valve area measurements using two-dimensional transoesophageal echocardiography and the potential of three-dimensional transoesophageal echocardiography
    Nakai, Hiromi
    Takeuchi, Masaaki
    Yoshitani, Hidetoshi
    Kaku, Kyoko
    Haruki, Nobuhiko
    Otsuji, Yutaka
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (04): : 369 - 376
  • [38] Mitral Annular Morphology in Mitral Valve Disease with Three-Dimensional Transesophageal Echocardiography
    Tani, Tomoko
    Kawai, Junichi
    Kitai, Takeshi
    Kim, Kitae
    Okada, Yukikatsu
    Kita, Toru
    Furukawa, Yutaka
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (02): : 193 - 199
  • [39] Anterior mitral valve perforation in the absence of acute infection: Diagnosis by two-dimensional and three-dimensional transesophageal echocardiography
    Mashicharan, Mary
    Cowburn, Peter J.
    Livesey, Steven A.
    Shah, Benoy N.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (12): : 1953 - 1955
  • [40] Quantitatification of mitral valve prolapse by real-time three-dimensional transesophageal echocardiography: a comparison with two-dimensional transesophageal echocardiography
    Izumo, M.
    Saito, T.
    Fukuoka, Y.
    Gurudevan, S. V.
    Tolstrup, K.
    Siegel, R. J.
    Shiota, T.
    EUROPEAN HEART JOURNAL, 2011, 32 : 1011 - 1012