Discrepancy between mitral valve areas measured by two-dimensional planimetry and three-dimensional transoesophageal echocardiography in patients with mitral stenosis

被引:45
|
作者
Min, Sun-Yang
Song, Jong-Min [1 ]
Kim, Yun-Jeong
Park, Hong-Kyung
Seo, Mi-Ohk
Lee, Moo-Song [2 ]
Kim, Dae-Hee
Kang, Duk-Hyun
Song, Jae-Kwan
机构
[1] Univ Ulsan, Coll Med, Dept Cardiol, Asan Med Ctr,Div Cardiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Div Biostat, Seoul 138736, South Korea
关键词
REAL-TIME; TRANSTHORACIC ECHOCARDIOGRAPHY; RECOMMENDATIONS; QUANTIFICATION; ACCURATE;
D O I
10.1136/heartjnl-2012-302742
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To compare mitral valve area (MVA) measurements obtained by 2D transthoracic planimetry and 3D transoesophageal echocardiography (TOE) in patients with mitral stenosis (MS), and to determine the causes of discrepancies between the two techniques. Design Reliability and agreement study. Setting Tertiary referral centre. Patients Eighty-seven patients with MS. Methods MVA was determined by transthoracic 2D planimetry and 3D TOE. Clinical and echocardiographic variables were evaluated. The angle (M alpha) between the lines of the true mitral valve (MV) tip and the echo beam-to-MV tip was measured at early diastole from the parasternal long-axis view obtained from 2D echocardiography. Results Although MVA measurements using 2D planimetry and 3D TOE showed good agreement (intraclass correlation coefficient, 0.853; p<0.001), 2D planimetry overestimated MVA by 0.19 +/- 0.2 cm(2) compared with 3D TOE (p<0.001). Left atrial (LA) dimension obtained from the parasternal long-axis view at end-systole (p=0.012), M alpha (p<0.001), and left ventricular ejection fraction (p=0.022) were independent determinants of the MVA difference (MVA by 2D-MVA by 3D TOE; MVA2D-3D) according to multiple linear regression analysis. The LA dimensions correlated with M alpha (r=0.352, p=0.001). The best cut-off values for predicting significant overestimation by 2D planimetry (MVA2D-3D>0.2 cm(2)) were LA dimension >= 49 mm (78% sensitivity, 72% specificity) and M alpha >= 9.5 degrees (56% sensitivity, 89% specificity). Conclusions Because 2D planimetry tends to overestimate MVA, 3D TOE should be considered for accurate MVA assessment, especially in patients with a large LA and large M alpha.
引用
收藏
页码:253 / 258
页数:6
相关论文
共 50 条
  • [21] Comparison of Real-Time Three-Dimensional Transesophageal Echocardiography to Two-Dimensional Transesophageal Echocardiography for Quantification of Mitral Valve Prolapse in Patients With Severe Mitral Regurgitation
    Izumo, Masaki
    Shiota, Maiko
    Kar, Saibal
    Gurudevan, Swaminatha V.
    Tolstrup, Kirsten
    Siegel, Robert J.
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (04): : 588 - 594
  • [22] COMPARISON OF DOPPLER ECHOCARDIOGRAPHY AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY IN THE MEASUREMENT OF MITRAL-VALVE AREA IN MITRAL-STENOSIS
    BRYG, RJ
    LABOVITZ, AJ
    NELSON, JG
    KENNEDY, HL
    WILLIAMS, GA
    CLINICAL RESEARCH, 1984, 32 (02): : A152 - A152
  • [23] Transapical mitral valve-in-valve implantation: a novel approach guided by three-dimensional transoesophageal echocardiography
    Nunez-Gil, Ivan J.
    Goncalves, Alexandra
    Rodriguez, Enrique
    Cobiella, Javier
    Marcos-Alberca, Pedro
    Maroto, Luis
    Fernandez-Golfin, Covadonga
    Carnero, Manuel
    Macaya, Carlos
    Zamorano, Jose L.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (04): : 335 - 337
  • [24] Three-dimensional echocardiography in congenital malformations of the mitral valve
    Espinola-Zavaleta, N
    Vargas-Barrón, J
    Keirns, C
    Rivera, G
    Romero-Cárdenas, A
    Roldán, J
    Attie, F
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (05) : 468 - 472
  • [25] Three-dimensional echocardiography in the management of parachute mitral valve
    Valverde, Israel
    Rawlins, Debbie
    Austin, Conal
    Simpson, John M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (05) : 446 - 446
  • [26] Three-dimensional reconstruction of mitral valve by transesophageal echocardiography
    Elmaghraby, Ahmed Mohamed
    Salustri, Alessandro
    HEART VIEWS, 2019, 20 (04): : 178 - 179
  • [27] Three-dimensional echocardiography for assessment of mitral valve regurgitation
    Sugeng, Lissa
    Chandra, Sonal
    Lang, Roberto M.
    CURRENT OPINION IN CARDIOLOGY, 2009, 24 (05) : 420 - 425
  • [28] Three-dimensional echocardiography to quantify mitral valve regurgitation
    Little, Stephen H.
    CURRENT OPINION IN CARDIOLOGY, 2012, 27 (05) : 477 - 484
  • [29] Three-Dimensional Echocardiography of the Mitral Valve: Lessons Learned
    Maffessanti, Francesco
    Mirea, Oana
    Tamborini, Gloria
    Pepi, Mauro
    CURRENT CARDIOLOGY REPORTS, 2013, 15 (07)
  • [30] Three-Dimensional Echocardiography of the Mitral Valve: Lessons Learned
    Francesco Maffessanti
    Oana Mirea
    Gloria Tamborini
    Mauro Pepi
    Current Cardiology Reports, 2013, 15