Use of fluorescent europium chelates as labels for detection of microcystin-LR in Taihu Lake, China

被引:5
|
作者
Niu Weimin [2 ]
He Enqi [2 ]
Wu Qinggang [2 ]
Zhou Weijie [2 ]
Zhang Yi [1 ]
Huang Biao [1 ]
Zhao Xiaolian [3 ]
机构
[1] Jiangsu Inst Nucl Med, Key Lab Nucl Med, Dept Biotechnol, Wuxi 214063, Peoples R China
[2] Lab Dept Municipal Ctr Dis Control & Prevent, Wuxi 214023, Peoples R China
[3] Jiangsu Suwei Microbiol Res Co Ltd, Wuxi 214063, Peoples R China
关键词
microcystin; time-resolved fluoroimmunoassay (TRFIA); water; dynamic detection; dead algae; rare earths; EXPRESSION; TOXINS;
D O I
10.1016/S1002-0721(12)60158-6
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A method using the time-resolved fluorescence technology to establish a highly sensitive microcystin-LR (MC-LR) indirect competitive immunoassay was proposed in this work. This method was used to monitor the MC-LR level in source water and treated drinking water from Taihu Lake. Algae in the water samples were removed by centrifugation, and the MC-LR level was quantified using this method. Testing results showed that the sensitivity of this method was 0.01 mu g/L, and the dynamic measuring range was from 0.05 to 2 mu g/L. The average recovery was 115%, and the variation (CV) within and between different batches were 7.3% and 9.7%, respectively. Testing results also indicated that this time-resolved fluoroimmunoassay was sensitive and accurate in measuring MC-LR level, especially for quantitative analysis MC-LR level in bulk water.
引用
收藏
页码:941 / 946
页数:6
相关论文
共 50 条
  • [31] Optical Cavity Fibre Sensor for Detection of Microcystin-LR in Water
    Queiros, Raquel B.
    Silva, S. O.
    Sales, M. G. F.
    Noronha, J. P.
    Frazao, O.
    Jorge, P. A. S.
    Aguilar, G. G.
    FOURTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2010, 7653
  • [32] Detection of Microcystin-LR in the Cells and Natural Lake Water Samples by A Unique Fluorescence-Based Method
    Yipeng Liu
    Bingyan Li
    Huixia Zhang
    Yong Liu
    Ping Xie
    Journal of Fluorescence, 2022, 32 : 505 - 519
  • [33] Unraveling the mechanisms underlying the fluorescent probe detection of microcystin-LR and its binding with CT-DNA
    Zhang, Huixia
    Chen, Jun
    Xie, Ping
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2025, 298
  • [34] Detection and quantification of Microcystis spp. and microcystin-LR in Western Lake Erie during the summer of 2007
    Wang, Hui
    Gruden, Cyndee L.
    Bridgeman, Thomas B.
    Chaffin, Justin D.
    WATER SCIENCE AND TECHNOLOGY, 2009, 60 (07) : 1837 - 1846
  • [35] First assessment of cyanobacterial blooms and microcystin-LR in the Canadian portion of Lake of the Woods
    Chen, Huirong
    Burke, Janice M.
    Dinsmore, W. Paul
    Prepas, Ellie E.
    Fedorak, Phillip M.
    LAKE AND RESERVOIR MANAGEMENT, 2007, 23 (02) : 169 - 178
  • [36] Influence of lake trophic status on the occurrence of microcystin-LR in the tissue of pulmonate snails
    Zurawell, RW
    Kotak, BG
    Prepas, EE
    FRESHWATER BIOLOGY, 1999, 42 (04) : 707 - 718
  • [37] An enhanced LC-MS/MS method for microcystin-LR in lake water
    Li, CM
    Chu, RYY
    Hsieh, DPH
    JOURNAL OF MASS SPECTROMETRY, 2006, 41 (02): : 169 - 174
  • [38] Persistence of cyanobacterial hepatotoxin, microcystin-LR in particulate material and dissolved in lake water
    Lahti, K
    Rapala, J
    Fardig, M
    Niemela, M
    Sivonen, K
    WATER RESEARCH, 1997, 31 (05) : 1005 - 1012
  • [39] Quantitative and rapid detection of microcystin-LR using time-resolved fluorescence immunochromatographic assay based on europium nanospheres
    Zhang, Yi
    Ding, Xin-Liang
    Guo, Ming-Ming
    Han, Ting-Ting
    Huang, Zi-Jian
    Shang, Hong-Tao
    Huang, Biao
    ANALYTICAL METHODS, 2017, 9 (45) : 6430 - 6434
  • [40] On-Off-On Fluorescent Chemosensors Based on N/P-Codoped Carbon Dots for Detection of Microcystin-LR
    Wang, Xiaoyan
    Yu, Jialuo
    Ji, Wan
    Arabi, Maryam
    Fu, Longwen
    Li, Bowei
    Chen, Lingxin
    ACS APPLIED NANO MATERIALS, 2021, 4 (07) : 6852 - 6860