Cobas Ampliprep/Cobas TaqMan HIV-1 v2.0 Assay: Consequences at the Cohort Level

被引:14
|
作者
Taylor, Ninon [1 ]
Grabmeier-Pfistershammer, Katharina [2 ]
Egle, Alexander [1 ]
Greil, Richard [1 ]
Rieger, Armin [2 ]
Ledergerber, Bruno [3 ]
Oberkofler, Hannes [4 ]
机构
[1] Paracelsus Med Univ, Dept Internal Med 3, Salzburg, Austria
[2] Vienna Med Univ, Dept Dermatol, Vienna, Austria
[3] Univ Zurich, Div Infect Dis & Hosp Epidemiol, Univ Zurich Hosp, Zurich, Switzerland
[4] Paracelsus Med Univ, Dept Lab Med, Salzburg, Austria
来源
PLOS ONE | 2013年 / 8卷 / 08期
关键词
PLASMA PREPARATION TUBES; VIRAL LOAD BLIPS; TIME PCR ASSAYS; ABBOTT REALTIME; ANTIRETROVIRAL THERAPY; INFECTED INDIVIDUALS; TYPE-1; LOAD; RNA LEVELS; VIREMIA; QUANTIFICATION;
D O I
10.1371/journal.pone.0074024
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: High-sensitive real-time PCR assays are routinely used to monitor HIV-1 infected subjects. Inter-assay discrepancies have been described at the low viral load (VL) end, where clinical decisions regarding possible virological rebound are based. Methods: A retrospective study was performed to analyze frequencies of viral blips after transition to the COBAS Ampliprep/COBAS TaqMan v2.0 HIV-1 assay (Taqman v2.0) in patients with prior undetectable VLs as measured with the Roche Cobas Ampliprep Amplicor HIV-1 Monitor Test, v1.5 (Amplicor) and was evaluated in comparison to a group of patients monitored with the Abbott Real-time HIV-1 assay (Abbott RT) during the same period of time. Results: 85 of 373 patients with VLs below the limit of quantification with Amplicor had VLs >50 copies/mL after transition to the TaqMan v2.0 assay. Among these 74.1% had VLs ranging from 50-499 copies/mL, 22.9% had VLs >500 copies/mL. From 22 patients with initial Taqman v2.0 based VLs exceeding 500 copies/mL, 6 patients had VLs <20 copies/mL after novel VL measurement on a next visit. In our control group with VL quantification using the Abbott RT assay, only 1 patient became detectable and showed a VL of <40 copies/mL after new measurement. Conclusions: Transition to the Taqman v2.0 assay was accompanied by an increase of quantifiable HIV-1 VLs in patients with long term viral suppression under antiretroviral therapy that might be attributed to technical shortcomings of the Taqman v2.0 assay. A high test variability at the low VL end but also beyond was observed, making meaningful clinical interpretation of viral blips derived from different assays difficult.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Evaluation of an Upgraded Version of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Test for HIV-1 Load Quantification
    Damond, F.
    Avettand-Fenoel, V.
    Collin, G.
    Roquebert, B.
    Plantier, J. C.
    Ganon, A.
    Sizmann, D.
    Babiel, R.
    Glaubitz, J.
    Chaix, M. L.
    Brun-Vezinet, F.
    Descamps, D.
    Rouzioux, C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (04) : 1413 - 1416
  • [32] Comparative Evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Version 2 Test Using the TaqMan 48 Analyzer and the Abbott RealTime HIV-1 Assay
    van Rensburg, Estrelita Janse
    Tait, Karen
    Watt, Alistair
    Schall, Robert
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (01) : 377 - 379
  • [33] PERFORMANCE CHARACTERISTICS OF THE COBAS AMPLIPREP/COBAS TAQMAN HCV QUANTITATIVE TEST, V2.0 FOR HCV-RNA DETECTION AND QUANTIFICATION
    Vermehren, J.
    Susser, S.
    Schutten, M.
    Fueller, C.
    Perner, D.
    Diepstraten-Pas, S.
    Molenkamp, R.
    Gohl, P.
    Colucci, G.
    Zitzer, H.
    Sarrazin, C.
    JOURNAL OF HEPATOLOGY, 2012, 56 : S364 - S364
  • [34] Verification of the Roche COBAS HIV-1, HCV and HBV Tests on the COBAS 6800 System and Correlation to the COBAS Ampliprep/COBAS TaqMan System
    Sabato, M.
    Barto, L.
    Margaritini, C.
    Earles, S.
    Anaya-Bergman, C.
    Sene, M.
    Ferreira-Gonzalez, A.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2019, 21 (06): : 1164 - 1164
  • [35] Comparison of the Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 and the Seimens Versant bDNA HIV-1 Version 3.0
    Dokus, B. J.
    Marchetti, A. L.
    Bentley, H. A.
    Bartels, C. L.
    Tsongalis, G. J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2009, 11 (06): : 639 - 639
  • [36] Initial evaluation of the Roche COBAS TaqMan HIV-1 v2.0 assay for determining viral load in HIV-infected individuals
    Taylor, Ninon
    Schmid, Ilse
    Egle, Alexander
    Greil, Richard
    Patsch, Wolfgang
    Oberkofler, Hannes
    ANTIVIRAL THERAPY, 2009, 14 (08) : 1189 - 1193
  • [37] Reproducibility of Roche cobas HIV-1, HBV and HCV real-time PCR assays on cobas 4800 in comparison with COBAS AmpliPrep/COBAS TaqMan assay equivalents
    Samat, M. N. Abdul
    Rashid, Z. Zainol
    Noordin, A.
    Ghulam, N. H.
    Ismail, N.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2020, 101 : 197 - 197
  • [38] Evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Test and Identification of Rare Polymorphisms Potentially Affecting Assay Performance
    Pyne, Michael T.
    Brown, Katherine L.
    Hillyard, David R.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (08) : 2852 - 2858
  • [39] Comparison of Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 (CAP/CTM v2.0) with other real-time PCR assays in HIV-1 monitoring and follow-up of low-level viral loads
    Wojewoda, Christina M.
    Spahlinger, Timothy
    Harmon, Marlene Louise
    Schnellinger, Brian
    Li, Qing
    Dejelo, Corazon
    Schmotzer, Christine
    Zhou, Lan
    JOURNAL OF VIROLOGICAL METHODS, 2013, 187 (01) : 1 - 5
  • [40] Successful use of Plasma Preparation Tubes™ (PPTs) in the COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Test
    Kraft, Colleen S.
    Binongo, Jose Nilo G.
    Burd, Eileen M.
    Eaton, Molly E.
    McCloskey, Cindy B.
    Fernandes, Helen
    Hill, Charles E.
    Caliendo, Angela M.
    JOURNAL OF CLINICAL VIROLOGY, 2013, 57 (01) : 77 - 79