Initial evaluation of the Roche COBAS TaqMan HIV-1 v2.0 assay for determining viral load in HIV-infected individuals

被引:12
|
作者
Taylor, Ninon [2 ,3 ]
Schmid, Ilse [1 ,2 ]
Egle, Alexander [2 ,3 ]
Greil, Richard [2 ,3 ]
Patsch, Wolfgang [1 ,2 ]
Oberkofler, Hannes [1 ,2 ]
机构
[1] Paracelsus Med Univ, Dept Lab Med, Salzburg, Austria
[2] Univ Klinikum Salzburg, Salzburg, Austria
[3] Paracelsus Med Univ, Dept Med 3, Salzburg, Austria
关键词
TIME PCR ASSAY; ABBOTT REALTIME; AMPLICOR; QUANTIFICATION; MONITOR; RNA; DISCREPANCIES; SUBTYPES;
D O I
10.3851/IMP1427
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: HIV type-1 (HIV-1) genetic diversity poses a challenge for the development of diagnostic tests based on nucleic acid amplification, which can be overcome, at least in part, by targeting multiple genomic regions. The new Roche Diagnostics COBAS TaqMan (CTM) HIV-1 v2.0 assay uses multiplex real-time PCR detection of sequences in the long terminal repeat and gag regions within the HIV-1 genome. Methods: We conducted initial comparative testing of HIV-1 viral load values in plasma samples from HIV-1-infected individuals using the Abbott RealTime HIV-1 (Abbott RT HIV-1), and the Roche CTM v1.0 and CTM v2.0 real-time PCR amplification systems, with a particular focus on patients previously undetectable or underestimated with the CTM v1.0 assay. Results: The new Roche CTM v2.0 assay showed excellent agreement with the other two assays over a wide dynamic range (r=0.9685). The assay also allowed accurate determination of viral load levels in individuals infected with HIV-1 isolates that were found falsely negative or underestimated with the Roche CTM v1.0 assay because of mutations within the gag region. Conclusions: The reliability and accuracy of the CTM v2.0 assay is similar to the Abbott RT HIV-1 assay. The implementation of a multiplex real-time PCR approach in the CTM v2.0 is a significant improvement in viral load testing in comparison with the CTM v1.0 assay.
引用
收藏
页码:1189 / 1193
页数:5
相关论文
共 50 条
  • [1] Comparison of the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test v1.0 with v2.0 in HIV-1 viral load quantification
    Tung, Yi-Ching
    Ke, Liang-Yin
    Lu, Po-Liang
    Lin, Kuei-Hsiang
    Lee, Su-Chen
    Lin, Yi-Ying
    Chou, Li-Chiu
    Tsai, Wen-Chan
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2015, 31 (04): : 188 - 193
  • [2] Performance evaluation of the COBAS/TaqMan HIV-1 v2.0 in HIV-1 positive patients with low viral load: A comparative study
    Paba, Pierpaolo
    Fabeni, Lavinia
    Ciccozzi, Massimo
    Perno, Carlo Federico
    Ciotti, Marco
    JOURNAL OF VIROLOGICAL METHODS, 2011, 173 (02) : 399 - 402
  • [3] COMPARISON OF THE APTIMA HIV-1 QUANT ASSAY TO THE COBAS AMPLIPREP/COBAS TAQMAN HIV-1 TEST, V2.0
    Hatzakis, A.
    Papachristou, H.
    Kantzanou, M.
    SEXUALLY TRANSMITTED INFECTIONS, 2013, 89 : A353 - A353
  • [4] Cobas Ampliprep/Cobas TaqMan HIV-1 v2.0 Assay: Consequences at the Cohort Level
    Taylor, Ninon
    Grabmeier-Pfistershammer, Katharina
    Egle, Alexander
    Greil, Richard
    Rieger, Armin
    Ledergerber, Bruno
    Oberkofler, Hannes
    PLOS ONE, 2013, 8 (08):
  • [5] Comparison of the Roche Cobas Ampliprep/Cobas Taqman v2.0 and Cobas 6800 for HIV, HCV, HBV and CMV Viral Load Determination
    Sundin, T. R.
    Seidman, D.
    Aunchman, M.
    Grissom, L.
    Inman, J.
    Mollica, P. A.
    Post, R.
    Shean, A.
    Slaughter, K.
    Nasim, S.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2018, 20 (06): : 935 - 935
  • [6] Comparison of the Aptima HIV-1 Quant Dx assay with the COBAS AmpliPrep/COBAS TaqMan HIV-1 v2.0 Test for HIV-1 viral load quantification in plasma samples from HIV-1-infected patients
    Longo, Serena
    Bon, Isabella
    Musumeci, Giuseppina
    Bertoldi, Alessia
    D'Urbano, Vanessa
    Calza, Leonardo
    Re, Maria Carla
    HEALTH SCIENCE REPORTS, 2018, 1 (04)
  • [7] Comparative evaluation of the Aptima HIV-1 Quant Dx assay and COBAS TaqMan HIV-1 v2.0 assay using the Roche High Pure System for the quantification of HIV-1 RNA in plasma
    Schalasta, Gunnar
    Boerner, Anna
    Speicher, Andrea
    Enders, Martin
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (03) : 493 - 499
  • [8] Comparison of the Hologic Aptima HIV-1 Quant Dx Assay to the Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 for the quantification of HIV-1 RNA in plasma samples
    Schonning, Kristian
    Johansen, Kim
    Landt, Bodil
    Benfield, Thomas
    Westh, Henrik
    JOURNAL OF CLINICAL VIROLOGY, 2017, 92 : 14 - 19
  • [9] Comparison of the QIAGEN artus HIV-1 QS-RGQ test with the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test v2.0
    Wall, G. R.
    Perinpanathan, D.
    Clark, D. A.
    JOURNAL OF CLINICAL VIROLOGY, 2012, 55 (01) : 62 - 66
  • [10] Comparison of the Hologic Aptima HIV-1 Quant Dx assay to the Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 for the quantification of HIV-RNA in plasma samples
    Schonning, K.
    Johansen, K.
    Landt, B.
    Benfield, T.
    Westh, H.
    JOURNAL OF CLINICAL VIROLOGY, 2016, 82 : S53 - S53