Voltammetric study of polyviologen and the application of polyviologen-modified glassy carbon electrode in amperometric detection of vitamin C

被引:10
|
作者
Hsu, P. -F. [1 ]
Ciou, W. -L. [1 ]
Chen, P. -Y. [1 ]
机构
[1] Kaohsiung Med Univ, Fac Med & Appl Chem, Kaohsiung 807, Taiwan
关键词
polyviologen; modified electrode; vitamin C; electropolymerization; amperometric;
D O I
10.1007/s10800-008-9555-x
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The voltammetric behavior of viologen oligomers prepared from butylviologen dibromide and the factors influencing polyviologen film formation were investigated at a glassy carbon electrode (GCE). Based on the voltammetric observations, phosphoric acid is crucial to the formation of a stable polyviologen film on a GCE. The polyviologen-modified glassy carbon electrode (PVGCE) was employed to determine vitamin C (i.e., ascorbic acid) in order to demonstrate the electroanalytical application of the electropolymerized polyviologen film. The PVGCE was found capable of accumulating vitamin C at electrode surface in a slightly basic solution (pH = 7.8) and induce a negative shift of oxidation potential of vitamin C. Vitamin C was detected by hydrodynamic amperometry at +0.1 V (vs. Ag/AgCl) in a batch-injection cell; no accumulation time is required. The dependence of oxidation current on concentration was linear from 5.00 x 10(-7) M to 1.22 x 10(-4) M with a regression coefficient of 0.9993. Several real samples were analyzed and the results exhibit good agreement with those determined by iodimetric titration.
引用
下载
收藏
页码:1285 / 1292
页数:8
相关论文
共 50 条
  • [1] Voltammetric study of polyviologen and the application of polyviologen-modified glassy carbon electrode in amperometric detection of vitamin C
    P.-F. Hsu
    W.-L. Ciou
    P.-Y. Chen
    Journal of Applied Electrochemistry, 2008, 38 : 1285 - 1292
  • [2] Direct determination of vitamin C in fruit juices using a polyviologen-modified electrode
    Zen, JM
    Tsai, DM
    Yang, HH
    ELECTROANALYSIS, 2002, 14 (22) : 1597 - 1600
  • [3] Polyviologen modified glassy carbon electrode employed for anodic stripping voltammetric determination of mercury(II)
    Cheng, Kuan-Chiao
    Chen, Po-Yu
    ELECTROANALYSIS, 2008, 20 (02) : 207 - 210
  • [4] Electrochemical Determination of Cu(II) Ions in Chloride-Rich Environment Using Polyviologen-Modified Glassy Carbon Electrodes
    Hsu, Pei-Fen
    Ciou, Wan-Lun
    Chen, Po-Yu
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2010, 57 (02) : 244 - 251
  • [5] Monitoring bioactivity in hydrogen fermentation by an amperometric method with polyviologen modified working electrode
    Bai, Ming-Der
    Wang, Yung-Fu
    Hsiao, Chia-Jung
    Li, Shiue-Lin
    Chang, Hsien-Chang
    Cheng, Sheng-Shung
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2006, 31 (10) : 1357 - 1364
  • [6] Amperometric Detection of Nitrite on Glassy Carbon Electrode Modified with Cobalt Nitroprusside
    Sabzi, R. E.
    PORTUGALIAE ELECTROCHIMICA ACTA, 2007, 25 (03) : 383 - 390
  • [7] Amperometric detection of indapamide on glassy carbon electrode
    Oliveira, Thawan G.
    Santos, Berlane G.
    Goncalves, Josue M.
    Angnes, Lucio
    ELECTROANALYSIS, 2023, 35 (09)
  • [8] Amperometric detection of morphine at preheated glassy carbon electrode modified with multiwall carbon nanotubes
    Salimi, A
    Hallaj, R
    Khayatian, GR
    ELECTROANALYSIS, 2005, 17 (10) : 873 - 879
  • [9] Voltammetric Detection of Paracetamol at Cobalt Ferrite Nanoparticles Modified Glassy Carbon Electrode
    Kumary, V. Anitha
    Divya, J.
    Nancy, T. E. Mary
    Sreevalsan, K.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (05): : 6610 - 6619
  • [10] Black phosphorene modified glassy carbon electrode for the sensitive voltammetric detection of rutin
    Niu, Xueliang
    Weng, Wenju
    Yin, Chunxiao
    Niu, Yanyan
    Li, Guangjiu
    Dong, Ruixia
    Men, Yongling
    Sun, Wei
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 811 : 78 - 83