Voltammetric study of polyviologen and the application of polyviologen-modified glassy carbon electrode in amperometric detection of vitamin C

被引:10
|
作者
Hsu, P. -F. [1 ]
Ciou, W. -L. [1 ]
Chen, P. -Y. [1 ]
机构
[1] Kaohsiung Med Univ, Fac Med & Appl Chem, Kaohsiung 807, Taiwan
关键词
polyviologen; modified electrode; vitamin C; electropolymerization; amperometric;
D O I
10.1007/s10800-008-9555-x
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The voltammetric behavior of viologen oligomers prepared from butylviologen dibromide and the factors influencing polyviologen film formation were investigated at a glassy carbon electrode (GCE). Based on the voltammetric observations, phosphoric acid is crucial to the formation of a stable polyviologen film on a GCE. The polyviologen-modified glassy carbon electrode (PVGCE) was employed to determine vitamin C (i.e., ascorbic acid) in order to demonstrate the electroanalytical application of the electropolymerized polyviologen film. The PVGCE was found capable of accumulating vitamin C at electrode surface in a slightly basic solution (pH = 7.8) and induce a negative shift of oxidation potential of vitamin C. Vitamin C was detected by hydrodynamic amperometry at +0.1 V (vs. Ag/AgCl) in a batch-injection cell; no accumulation time is required. The dependence of oxidation current on concentration was linear from 5.00 x 10(-7) M to 1.22 x 10(-4) M with a regression coefficient of 0.9993. Several real samples were analyzed and the results exhibit good agreement with those determined by iodimetric titration.
引用
下载
收藏
页码:1285 / 1292
页数:8
相关论文
共 50 条
  • [21] A Comparative Study on Voltammetric Behavior of Dopamine at Glassy Carbon Electrode and PANI/MoS2-Modified Glassy Carbon Electrode
    Anjali
    Thakur, K. K.
    Kaur, K.
    Singh, S.
    RUSSIAN JOURNAL OF GENERAL CHEMISTRY, 2024, 94 (04) : 897 - 903
  • [22] Voltammetric study of the hydrolysis product of fenthion at the Nafion®-modified glassy carbon electrode
    G. Erdoğdu
    Journal of Analytical Chemistry, 2007, 62 : 466 - 469
  • [23] Voltammetric study of the hydrolysis product of fenthion at the Nafion®-modified glassy carbon electrode
    Erdogdu, G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 62 (05) : 466 - 469
  • [24] APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL
    Piech, Robert
    Paczosa-Bator, Beata
    ACTA POLONIAE PHARMACEUTICA, 2015, 72 (06): : 1081 - 1088
  • [25] Glassy carbon electrode modified with organic–inorganic pillared montmorillonites for voltammetric detection of mercury
    Baohong Chen
    Lishi Wang
    Xinjian Huang
    Pingxiao Wu
    Microchimica Acta, 2011, 172 : 335 - 341
  • [26] Voltammetric determination of mitomycin C using a chemically-modified glassy carbon electrode
    Qu, WY
    Wang, H
    Wu, HB
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2005, 70 (02) : 178 - 187
  • [27] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [28] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23
  • [29] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Surface Engineering and Applied Electrochemistry, 2024, 60 : 15 - 23
  • [30] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984