Black phosphorene modified glassy carbon electrode for the sensitive voltammetric detection of rutin

被引:43
|
作者
Niu, Xueliang [1 ]
Weng, Wenju [2 ]
Yin, Chunxiao [2 ]
Niu, Yanyan [1 ]
Li, Guangjiu [2 ]
Dong, Ruixia [1 ]
Men, Yongling [1 ]
Sun, Wei [1 ]
机构
[1] Hainan Normal Univ, Coll Chem & Chem Engn, Minist Educ, Key Lab Trop Med Plant Chem, Haikou 571158, Hainan, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
基金
中国国家自然科学基金;
关键词
Black phosphorene; Poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate); Rutin; Electroanalysis; REDUCED GRAPHENE OXIDE; ELECTROCHEMICAL SENSOR; PASTE ELECTRODE; COMPOSITE; NANOTUBE; FLAVONOIDS; BEHAVIOR; PLATFORM;
D O I
10.1016/j.jelechem.2018.01.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As a common flavonoid glycoside, rutin owns excellent physiologic activities and has been widely used in clinical chemistry and human health. Therefore the establishment of sensitive and reliable methods for rutin determination is highly important. Black phosphorene (BP) nanoshcet modified glassy carbon electrode (GCE) was fabricated by using poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) as the film and the stabilizer. The incorporation of BP with PEDOT:PSS resulted in a stable nanocomposite (BP-PEDOT:PSS) and its performance were characterized by SEM, EDS and Raman. BP-PEDOT:PSS/GCE showed excellent conductivity and stability, which was applied for the sensitive voltammetric determination of rutin, a commonly used electroactive drug. On cyclic voltammogram a pair of well-defined redox peak of rutin could be obviously observed with enhanced voltammetric response, which could be due to the presence of BP nanosheet that accelerated the electrode reaction. Electrochemical parameters were calculated with the electron transfer coefficient (alpha) as 0.55 and the apparent heterogeneous electron transfer rate constant (k(s)) as 4.22 s(-1). Under the selected conditions differential pulse voltammetric oxidation peak current of rutin showed linear dependence on its concentration within two sections of 0.02-15.0 mu mol/L and 15.0-80.0 mu mol/L with a low detection limit of 0.007 mu mol/L (3S(0)/S). Rutin tablet samples were successfully examined by the as-proposed method with satisfactory results, showing the practical applications.
引用
收藏
页码:78 / 83
页数:6
相关论文
共 50 条
  • [1] Graphene Nanosheets Modified Glassy Carbon Electrode as a Highly Sensitive and Selective Voltammetric Sensor for Rutin
    Du, Haijun
    Ye, Jianshan
    Zhang, Jiaqi
    Huang, Xiaodan
    Yu, Chengzhong
    [J]. ELECTROANALYSIS, 2010, 22 (20) : 2399 - 2406
  • [2] Application of ionic liquid modified carbon ceramic electrode for the sensitive voltammetric detection of rutin
    Zhan, Tianrong
    Sun, Xiaoying
    Wang, Xiuzhen
    Sun, Wei
    Hou, Wanguo
    [J]. TALANTA, 2010, 82 (05) : 1853 - 1857
  • [3] Application of a glassy carbon electrode modified with carbon black nanoparticles for highly sensitive voltammetric determination of quetiapine
    Lawrywianiec, M.
    Smajdor, J.
    Paczosa-Bator, B.
    Piech, R.
    [J]. ANALYTICAL METHODS, 2017, 9 (47) : 6662 - 6668
  • [4] Sensitive voltammetric determination of rutin at an ionic liquid modified carbon paste electrode
    Zhanga, Ya
    Zhenga, Jianbin
    [J]. TALANTA, 2008, 77 (01) : 325 - 330
  • [5] Highly sensitive voltammetric determination of hydrochlorothiazide using a glassy carbon electrode modified with Super P carbon black nanoparticles
    Santos-Neto, Domingos R.
    Lopes, Carlos E. C.
    Silva, Gabrielly P.
    Castro, Lizandra N.
    Silva, Joao Pedro C.
    Ferreira, Dianderson C. M.
    Silva, Luiz Ricardo G.
    Dantas, Luiza M. F.
    da Silva, Iranaldo S.
    [J]. ANALYTICAL METHODS, 2024, 16 (36) : 6271 - 6278
  • [6] Voltammetric sensing performances of a carbon ionic liquid electrode modified with black phosphorene and hemin
    Li, Xiaoyan
    Luo, Guiling
    Xie, Hui
    Niu, Yanyan
    Li, Xiaobao
    Zou, Ruyi
    Xi, Yaru
    Xiong, Yi
    Sun, Wei
    Li, Guangjiu
    [J]. MICROCHIMICA ACTA, 2019, 186 (05)
  • [7] Voltammetric sensing performances of a carbon ionic liquid electrode modified with black phosphorene and hemin
    Xiaoyan Li
    Guiling Luo
    Hui Xie
    Yanyan Niu
    Xiaobao Li
    Ruyi Zou
    Yaru Xi
    Yi Xiong
    Wei Sun
    Guangjiu Li
    [J]. Microchimica Acta, 2019, 186
  • [8] A sensitive voltammetric analysis and detection of Alizarin Red S onto a glassy carbon electrode modified by an organosmectite
    Deffo G.
    Tonleu Temgoua R.C.
    Foukmeniok Mbokou S.
    Njanja E.
    Kenfack Tonlé I.
    Ngameni E.
    [J]. Sensors International, 2021, 2
  • [9] Sensitive Voltammetric Determination of Ethinyl Estradiol on Carbon Black Modified Electrode
    Smajdor, Joanna
    Piech, Robert
    Piek, Magdalena
    Paczosa-Bator, Beata
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (13) : H885 - H889
  • [10] Carbon Black Modified Glassy Carbon Electrode For The Detection Of Antioxidants Compounds
    Compagnone, D.
    Del Carlo, M.
    Innocenzi, D.
    Arduini, F.
    Agui, L.
    Serafin, V.
    [J]. 2015 18TH AISEM ANNUAL CONFERENCE, 2015,