Use of the 'real-ear to dial difference' to derive real-ear SPL from hearing level obtained with insert earphones

被引:15
|
作者
Munro, KJ [1 ]
Lazenby, A [1 ]
机构
[1] Univ Southampton, Inst Sound & Vibrat Res, Hearing & Balance Ctr, Southampton SO17 1BJ, Hants, England
来源
BRITISH JOURNAL OF AUDIOLOGY | 2001年 / 35卷 / 05期
关键词
real-ear sound pressure level; real-ear to dial difference (REDD);
D O I
10.1080/00305364.2001.11745248
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The electroacoustic characteristics of a hearing instrument are normally selected for individuals using data obtained during audiological assessment. The precise inter-relationship between the electroacoustic and audiometric variables is most readily appreciated when they have been measured at the same reference point, such as the tympanic membrane. However, it is not always possible to obtain the real-ear sound pressure level (SPL) directly if this is below the noise floor of the probe-tube microphone system or if the subject is unco-operative. The real-ear SPL may be derived by adding the subject's real-ear to dial difference (REDD) acoustic transform to the audiometer dial setting. The aim of the present study was to confirm the validity of the Audioscan RM500 to measure the REDD with the ER-3A insert earphone. A probe-tube microphone was used to measure the real-ear SPL and REDD from the right ears of 16 adult subjects ranging in age from 22 to 41 years (mean age 27 years). Measurements were made from 0.25 kHz to 6 kHz at a dial setting of 70 dB with an ER-3A insert earphone and two earmould configurations: the EAR-LINK foam car-tip and the subjects' customized skeleton earmoulds. Mean REDD varied as a function of frequency but was typically approximately 12 dB with a standard deviation (SD) of +/-1.7 dB and +/-2.7 dB for the foam ear-tip and customized earmould, respectively. The mean test-retest difference of the REDD varied with frequency but was typically 0.5 dB (SD I dB). Over the frequency range 0.5-4 kHz, the derived values were found to be within 5 dB of the measured values in 95% of subjects when using the EAR-LINK foam ear-tip and within 4 dB when using the skeleton earmould. The individually measured REDD transform can be used in clinical practice to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.
引用
收藏
页码:297 / 306
页数:10
相关论文
共 50 条
  • [41] The effects of venting on in-the-ear, in-the-canal, and completely-in-the-canal hearing aid shell frequency responses: Real-ear measures
    Stuart, A
    Allen, R
    Downs, CR
    Carpenter, M
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 1999, 42 (04): : 804 - 813
  • [42] Anticipating real-ear insertion response using an external auditory canal model
    Taiji, Hidenobu
    Okamoto, Yasuhide
    Kanzaki, Jin
    AURIS NASUS LARYNX, 2022, 49 (03) : 389 - 395
  • [43] SOUND-FIELD DIFFUSIVITY AND REVERBERATION EFFECTS ON THE REAL-EAR ATTENUATION OF HEARING PROTECTORS WITH IMPLICATIONS FOR TESTING STANDARDS
    ROBINSON, GS
    MAUNEY, DW
    CASALI, JG
    NOISE CONTROL ENGINEERING JOURNAL, 1993, 40 (02) : 199 - 210
  • [44] Venting Corrections Improve the Accuracy of Coupler-Based Simulated Real-Ear Verification for Use with Adult Hearing Aid Fittings
    Scollie, Susan
    Folkeard, Paula
    Pumford, John
    Abbasalipour, Parvaneh
    Pietrobon, Jonathan
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2022, 33 (05) : 277 - 284
  • [45] Extended bandwidth real-ear measurement accuracy and repeatability to 10kHz
    Vaisberg, Jonathan M.
    Macpherson, Ewan A.
    Scollie, Susan D.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2016, 55 (10) : 580 - 586
  • [46] INFLUENCE OF PHYSIOLOGICAL NOISE AND THE OCCLUSION EFFECT ON THE MEASUREMENT OF REAL-EAR ATTENUATION AT THRESHOLD
    BERGER, EH
    KERIVAN, JE
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1983, 74 (01): : 81 - 94
  • [47] Is the role of probe-tube, real-ear measurements changing for adults with mild-to-moderate hearing loss?
    Almufarrij, Ibrahim
    Sindi, Nasreen
    Pepler, Anna
    Munro, Kevin J.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2024,
  • [48] INFLUENCE OF PHYSIOLOGICAL NOISE AND THE OCCLUSION EFFECT ON THE MEASUREMENT OF REAL-EAR ATTENUATION AT THRESHOLD.
    Berger, E.H.
    Kerivan, J.E.
    1600, (74):
  • [49] REAL-EAR CALIBRATION OF IPSILATERAL ACOUSTIC REFLEX STIMULI FROM 5 TYPES OF IMPEDANCE METER
    LUTMAN, ME
    SCANDINAVIAN AUDIOLOGY, 1980, 9 (03): : 137 - 145
  • [50] REAL-EAR ATTENUATION CHARACTERISTICS OF SELECTED NOISE-EXCLUDING AUDIOMETRIC RECEIVER ENCLOSURES
    COPELAND, AB
    MOWRY, HJ
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1971, 49 (06): : 1757 - &