Use of the 'real-ear to dial difference' to derive real-ear SPL from hearing level obtained with insert earphones

被引:15
|
作者
Munro, KJ [1 ]
Lazenby, A [1 ]
机构
[1] Univ Southampton, Inst Sound & Vibrat Res, Hearing & Balance Ctr, Southampton SO17 1BJ, Hants, England
来源
BRITISH JOURNAL OF AUDIOLOGY | 2001年 / 35卷 / 05期
关键词
real-ear sound pressure level; real-ear to dial difference (REDD);
D O I
10.1080/00305364.2001.11745248
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The electroacoustic characteristics of a hearing instrument are normally selected for individuals using data obtained during audiological assessment. The precise inter-relationship between the electroacoustic and audiometric variables is most readily appreciated when they have been measured at the same reference point, such as the tympanic membrane. However, it is not always possible to obtain the real-ear sound pressure level (SPL) directly if this is below the noise floor of the probe-tube microphone system or if the subject is unco-operative. The real-ear SPL may be derived by adding the subject's real-ear to dial difference (REDD) acoustic transform to the audiometer dial setting. The aim of the present study was to confirm the validity of the Audioscan RM500 to measure the REDD with the ER-3A insert earphone. A probe-tube microphone was used to measure the real-ear SPL and REDD from the right ears of 16 adult subjects ranging in age from 22 to 41 years (mean age 27 years). Measurements were made from 0.25 kHz to 6 kHz at a dial setting of 70 dB with an ER-3A insert earphone and two earmould configurations: the EAR-LINK foam car-tip and the subjects' customized skeleton earmoulds. Mean REDD varied as a function of frequency but was typically approximately 12 dB with a standard deviation (SD) of +/-1.7 dB and +/-2.7 dB for the foam ear-tip and customized earmould, respectively. The mean test-retest difference of the REDD varied with frequency but was typically 0.5 dB (SD I dB). Over the frequency range 0.5-4 kHz, the derived values were found to be within 5 dB of the measured values in 95% of subjects when using the EAR-LINK foam ear-tip and within 4 dB when using the skeleton earmould. The individually measured REDD transform can be used in clinical practice to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.
引用
收藏
页码:297 / 306
页数:10
相关论文
共 50 条
  • [31] The influence of RECD transducer when deriving real-ear sound pressure level
    Munro, Kevin J.
    Millward, Kerri E.
    EAR AND HEARING, 2006, 27 (04): : 409 - 423
  • [32] Differences in Sensation Level between the Widex SoundTracker and Two Real-Ear Analyzers
    Oeding, Kristi
    Valente, Michael
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2013, 24 (08) : 660 - 670
  • [33] Comparison between the International Outcome Inventory for Hearing Aids Questionnaire and Real-Ear Measurement
    Nam, Gi-Sung
    Lee, Young Jae
    Song, Hansoo
    Oh, Jeonghyun
    Cho, Sung Il
    AUDIOLOGY AND NEUROTOLOGY, 2025, 30 (01) : 52 - 57
  • [34] Distribution of standing-wave errors in real-ear sound-level measurements
    Richmond, Susan A.
    Kopun, Judy G.
    Neely, Stephen T.
    Tan, Hongyang
    Gorga, Michael P.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 129 (05): : 3134 - 3140
  • [35] NIST System for Measuring the Directivity Index of Hearing Aids under Simulated Real-Ear Conditions
    Wagner, Randall P.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2013, 118 : 105 - 124
  • [36] COMPARISON BETWEEN OBJECTIVE AND THRESHOLD-SHIFT METHODS OF MEASURING REAL-EAR ATTENUATION OF EXTERNAL SOUND BY EARPHONES
    VILLCHUR, E
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1972, 51 (02): : 663 - &
  • [37] Estimating Earphone Level and Dose Using Real-Ear Measures and Ecological Momentary Assessment
    Jorgensen, Erik
    Reynolds, Isabelle
    Saxena, Trisha
    Thomas, Marisa
    Werner, Megan
    AMERICAN JOURNAL OF AUDIOLOGY, 2025, 34 (01) : 211 - 219
  • [38] Coupler and real-ear measurement of hearing aid gain and output in the NIDCD/VA Hearing Aid Clinical Trial
    Bratt, GW
    Rosenfeld, MAL
    Peek, BF
    Kang, J
    Williams, DW
    Larson, V
    EAR AND HEARING, 2002, 23 (04): : 308 - 315
  • [39] Development of the speech test signal in Brazilian Portuguese for real-ear measurement
    Garolla, Luciana P.
    Scollie, Susan D.
    Martinelli Iorio, Maria Cecilia
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2013, 52 (08) : 572 - 576
  • [40] NIDC/VA hearing aid clinical trial and follow-up: Coupler and real-ear measurement
    Peek, Barbara F.
    Rosenfeld, Mia A. L.
    Brattt, Gene W.
    Williams, David W.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2007, 18 (04) : 282 - 291