Accuracy of Real-time Couch Tracking During 3-dimensional Conformal Radiation Therapy, Intensity Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Prostate Cancer

被引:31
|
作者
Wilbert, Juergen [1 ]
Baier, Kurt [1 ]
Hermann, Christian [2 ]
Flentje, Michael [1 ]
Guckenberger, Matthias [1 ]
机构
[1] Univ Wurzburg, Dept Radiat Oncol, D-97080 Wurzburg, Germany
[2] Univ Wurzburg, Dept Comp Sci Robot & Telemat 7, D-97080 Wurzburg, Germany
关键词
Prostate cancer; Intrafractional uncertainties; Real-time tracking; Phantom study; Intensity modulated radiation therapy; INTRAFRACTION MOTION; RADIOTHERAPY; SYSTEM; FEASIBILITY; TARGETS; MARKER; RECTUM;
D O I
10.1016/j.ijrobp.2012.01.095
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the accuracy of real-time couch tracking for prostate cancer. Methods and Materials: Intrafractional motion trajectories of 15 prostate cancer patients were the basis for this phantom study; prostate motion had been monitored with the Calypso System. An industrial robot moved a phantom along these trajectories, motion was detected via an infrared camera system, and the robotic HexaPOD couch was used for real-time counter-steering. Residual phantom motion during real-time tracking was measured with the infrared camera system. Film dosimetry was performed during delivery of 3-dimensional conformal radiation therapy (3D-CRT), step-and-shoot intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Results: Motion of the prostate was largest in the anteriore-posterior direction, with systematic (Sigma) and random (sigma) errors of 2.3 mm and 2.9 mm, respectively; the prostate was outside a threshold of 5 mm (3D vector) for 25.0%+/- 19.8% of treatment time. Real-time tracking reduced prostate motion to Sigma = 0.01 mm and sigma = 0.55 mm in the anterior-posterior direction; the prostate remained within a 1-mm and 5-mm threshold for 93.9% +/- 4.6% and 99.7%+/- 0.4% of the time, respectively. Without real-time tracking, pass rates based on a gamma index of 2%/2 mm in film dosimetry ranged between 66% and 72% for 3D-CRT, IMRT, and VMAT, on average. Real-time tracking increased pass rates to minimum 98% on average for 3D-CRT, IMRT, and VMAT. Conclusions: Real-time couch tracking resulted in submillimeter accuracy for prostate cancer, which transferred into high dosimetric accuracy independently of whether 3D-CRT, IMRT, or VMAT was used. (c) 2013 Elsevier Inc.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 50 条
  • [41] Plan Robustness Study of Volumetric Modulated Arc Therapy Versus Intensity Modulated Radiation Therapy for Head and Neck Cancer
    Liu, W.
    Patel, S. H.
    Shen, J.
    Stoker, J.
    Ding, X.
    Hu, Y.
    Wong, W. W.
    Halyard, M. Y.
    Ezzell, G. A.
    Schild, S. E.
    Bues, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E567 - E568
  • [42] The Dosimetric Performance of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy in the Treatment of Locally Advanced Laryngeal Cancer
    Khater, Firas
    Attalla, Ehab
    Elshemey, Wael
    Mohammed, Haitham
    MIDDLE EAST JOURNAL OF CANCER, 2024, 15 (01) : 25 - 39
  • [43] Dosimetric, Radiobiological and Secondary Cancer Risk Evaluation in Head-and-Neck Three-dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy: A Phantom Study
    Rehman, Jalil Ur
    Isa, Muhammad
    Ahmad, Nisar
    Nasar, Gulfam
    Asghar, H. M. Noor Ul Huda Khan
    Gilani, Zaheer Abbas
    Chow, James C. L.
    Afzal, Muhammad
    Ibbott, Geoffrey S.
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (02) : 129 - 135
  • [44] A Comparative Study on the Head and Neck Radiation Therapy for Dynamic Conformal Arc Therapy and Volumetric Modulated Arc Therapy
    Kim, Deok-Ki
    Choi, Cheon Woong
    Choi, Jae-Hyock
    Won, Hui-Su
    Park, Cheol-Soo
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2015, 25 (06): : 208 - 218
  • [45] Megavoltage X-Ray Volumetric Modulated Arc Therapy and Multi-Entrance Three Dimensional Conformal Radiation Therapy for Prostate Cancer
    Assaoui, F.
    Lachgar, A.
    Benjaafar, N.
    AFRICAN REVIEW OF PHYSICS, 2020, 15 : 177 - 183
  • [46] Treatment Outcomes of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Patients With Maxillary Sinus Cancer in the Postoperative Setting
    Suh, Y.
    Geol, L. Chang
    Keum, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S543 - S544
  • [47] Assessment of Robustly Optimized Intensity Modulated Proton Therapy and Volumetric Modulated Arc Therapy for Prostate Cancer
    Brovold, N.
    King, A.
    Xu, Y.
    Diwanji, T.
    Pollack, A.
    Dogan, N.
    MEDICAL PHYSICS, 2019, 46 (06) : E625 - E625
  • [48] Intensity-Modulated Radiation Therapy, Proton Therapy, or Conformal Radiation Therapy and Morbidity and Disease Control in Localized Prostate Cancer
    Sheets, Nathan C.
    Goldin, Gregg H.
    Meyer, Anne-Marie
    Wu, Yang
    Chang, YunKyung
    Stuermer, Til
    Holmes, Jordan A.
    Reeve, Bryce B.
    Godley, Paul A.
    Carpenter, William R.
    Chen, Ronald C.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 307 (15): : 1611 - 1620
  • [49] Preliminary Toxicity Analysis of 3-Dimensional Conformal Radiation Therapy Versus Intensity Modulated Radiation Therapy on the High-Dose Arm of the Radiation Therapy Oncology Group 0126 Prostate Cancer Trial
    Michalski, Jeff M.
    Yan, Yan
    Watkins-Bruner, Deborah
    Bosch, Walter R.
    Winter, Kathryn
    Galvin, James M.
    Bahary, Jean-Paul
    Morton, Gerard C.
    Parliament, Matthew B.
    Sandler, Howard M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (05): : 932 - 938
  • [50] Dosimetric Comparison of Volumetric Modulated Arc Therapy, Tomotherapy, and Intensity Modulated Radiation Therapy for Radiation Dose Escalation of Hepatic Malignancies
    Bota, K.
    Lock, M.
    Ahmad, B.
    Fisher, B.
    Yartsev, S.
    Wong, E.
    Gaede, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S381 - S382