Investigation of built-up box columns composed of four cold-formed steel channels

被引:9
|
作者
Nie, Shaofeng [1 ]
Eatherton, Matthew R. [2 ]
Han, Yong [1 ]
Zhou, Tianhua [1 ]
Wu, Hanheng [1 ]
Li, Jiang [3 ]
机构
[1] Changan Univ, Sch Civil Engn, Xi'an 710061, Peoples R China
[2] Virginia Tech, Dept Civil & Environm Engn, Blacksburg, VA 24061 USA
[3] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
基金
中国国家自然科学基金;
关键词
CFS built-up box columns; Cold-formed steel; Compression strength; Compressive behavior; Numerical investigation; Design methods; CLOSED SECTION COLUMNS; BEHAVIOR; DESIGN; TESTS; CAPACITY;
D O I
10.1016/j.tws.2022.109258
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A three part study was conducted to investigate the compression behavior of a built-up box column made from four cold-formed steel (CFS) channels, including an experimental program, finite element study, and evaluation of building code prediction approaches. The experimental study included fifteen box column specimens with various effective lengths and varied eccentricity. Twist and warping of the ends of the specimen were restrained. The test results indicated that the dominant failure modes were global flexural buckling, local buckling, and concentrated localized deformation caused by local buckling. A finite element (FE) study was then conducted to broaden the investigation beyond the tested configurations and it was found that varying the screw spacing from 150 mm to 450 mm has little influence on the axial compressive behavior (less than 4%) and that web height-to-thickness ratio was a key parameter affecting axial compression strength. Finally, the accuracy and applicability of the available design methods for predicting the strength of the box columns were evaluated including the "effective width method " in which the modified slenderness ratio was not considered in AISI S100-16, the "direct strength method " in AISI S100-16, the method in the Chinese building code, and the method in EN 1993-1-3. For the box columns considered in this study, the four design methods produced predictions of the concentric axial compression strength that were between -33% to +6% of the expected actual strength. The selected design methods produced the average results of eccentric axial compression strengths that were between 8% to 25% conservative as compared to the test and FEA results.
引用
收藏
页数:22
相关论文
共 50 条
  • [42] RESISTANCE OF BUILT-UP COLD-FORMED STEEL CHANNEL COLUMNS FILLED WITH CONCRETE
    Sani, Mohd Syahrul Hisyam Mohd
    Muftah, Fadhluhartini
    Muda, Mohd Fakri
    Tan, Cher Siang
    JURNAL TEKNOLOGI, 2016, 78 (5-2): : 99 - 104
  • [43] Experiments on the global buckling and collapse of built-up cold-formed steel columns
    Fratamico, David C.
    Torabian, Shahabeddin
    Zhao, Xi
    Rasmussen, Kim J. R.
    Schafer, Benjamin W.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 144 : 65 - 80
  • [44] Computational modelling of built-up cold-formed steel columns and parametric studies
    Abbasi, Mandana
    Rasmussen, Kim J. R.
    Khezri, Mani
    Schafer, Benjamin W.
    THIN-WALLED STRUCTURES, 2023, 191
  • [45] Compression Test on Cold-Formed Steel Built-up Back-to-Back Channels Stub Columns
    Ting, Chui Huon Tina
    Lau, Hieng Ho
    ADVANCED MANUFACTURING SYSTEMS, PTS 1-3, 2011, 201-203 : 2900 - 2903
  • [46] Investigation on Axial Capacity of Cold-Formed Aluminium Alloy Built-Up Columns
    Jacob S.
    Aneeshkumar S.L.
    Ajeesh S.S.
    Journal of The Institution of Engineers (India): Series A, 2024, 105 (02) : 371 - 382
  • [47] Investigation on Distortion Buckling Behavior of Cold-formed Thin-walled Steel Built-up Box-section Columns
    Li Y.
    Zhou T.
    Ding J.
    Li C.
    Zhang X.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2021, 48 (11): : 91 - 100
  • [48] A NUMERICAL INVESTIGATION ON COLD-FORMED STEEL BUILT-UP BACK-TO-BACK CHANNEL STUB COLUMNS
    Ting, T. C. H.
    Lau, H. H.
    Proceedings of the 7th International Conference on Steel and Aluminium Structures (ICSAS 2011), 2011, : 443 - 449
  • [49] Experimental and numerical investigation on cold-formed steel built-up section pin-ended columns
    Li, Qiu-Yun
    Young, Ben
    THIN-WALLED STRUCTURES, 2022, 170
  • [50] Experimental analysis on behavior of cold-formed steel box built-up section columns under axial compression
    Nie, Shaofeng
    Zhou, Tianhua
    Yuan, Taotao
    Gao, Tingting
    Wu, Hanheng
    Tumu Jianzhu yu Huanjing Gongcheng/Journal of Civil, Architectural and Environmental Engineering, 2012, 34 (04): : 46 - 52