Investigation of built-up box columns composed of four cold-formed steel channels

被引:9
|
作者
Nie, Shaofeng [1 ]
Eatherton, Matthew R. [2 ]
Han, Yong [1 ]
Zhou, Tianhua [1 ]
Wu, Hanheng [1 ]
Li, Jiang [3 ]
机构
[1] Changan Univ, Sch Civil Engn, Xi'an 710061, Peoples R China
[2] Virginia Tech, Dept Civil & Environm Engn, Blacksburg, VA 24061 USA
[3] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
基金
中国国家自然科学基金;
关键词
CFS built-up box columns; Cold-formed steel; Compression strength; Compressive behavior; Numerical investigation; Design methods; CLOSED SECTION COLUMNS; BEHAVIOR; DESIGN; TESTS; CAPACITY;
D O I
10.1016/j.tws.2022.109258
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A three part study was conducted to investigate the compression behavior of a built-up box column made from four cold-formed steel (CFS) channels, including an experimental program, finite element study, and evaluation of building code prediction approaches. The experimental study included fifteen box column specimens with various effective lengths and varied eccentricity. Twist and warping of the ends of the specimen were restrained. The test results indicated that the dominant failure modes were global flexural buckling, local buckling, and concentrated localized deformation caused by local buckling. A finite element (FE) study was then conducted to broaden the investigation beyond the tested configurations and it was found that varying the screw spacing from 150 mm to 450 mm has little influence on the axial compressive behavior (less than 4%) and that web height-to-thickness ratio was a key parameter affecting axial compression strength. Finally, the accuracy and applicability of the available design methods for predicting the strength of the box columns were evaluated including the "effective width method " in which the modified slenderness ratio was not considered in AISI S100-16, the "direct strength method " in AISI S100-16, the method in the Chinese building code, and the method in EN 1993-1-3. For the box columns considered in this study, the four design methods produced predictions of the concentric axial compression strength that were between -33% to +6% of the expected actual strength. The selected design methods produced the average results of eccentric axial compression strengths that were between 8% to 25% conservative as compared to the test and FEA results.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Numerical investigation on the composite action of cold-formed steel built-up battened columns
    Rahnavard, Rohola
    Craveiro, Helder D.
    Laim, Luis
    Simoes, Rui A.
    Napolitano, Rebecca
    THIN-WALLED STRUCTURES, 2021, 162
  • [22] Mechanics of cold-formed steel built-up box section columns in local buckling modes
    Li, Yanchun
    Li, Ruibo
    Zhou, Tianhua
    Han, Aihong
    Li, Weihua
    STRUCTURES, 2025, 71
  • [23] The Evolution and Performance of Cold-Formed Steel Built-Up Battened Columns
    Jainudin, N. F.
    Jamaluddin, N.
    Jaini, Zainorizuan Mohd
    Hakim, S. J. s
    Mohamad, Noridah
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2024, 16 (05): : 444 - 453
  • [24] Closed built-up cold-formed steel columns under compression
    Craveiro, Hélder D.
    Rahnavard, Rohola
    Santiago, Aldina
    Laím, Luís
    Simões, Rui
    ce/papers, 2023, 6 (3-4) : 1941 - 1946
  • [25] Strength buckling predictions of cold-formed steel built-up columns
    Megnounif, A.
    Djafour, M.
    Belarbi, A.
    Kerdal, D.
    STRUCTURAL ENGINEERING AND MECHANICS, 2008, 28 (04) : 443 - 460
  • [26] Structural optimization of closed built-up cold-formed steel columns
    Laim, Luis
    Mendes, Jerome
    Craveiro, Helder D.
    Santiago, Aldina
    Melo, Carlos
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 193
  • [27] Flexural strength of cold-formed steel built-up box sections
    Xu, Lei
    Sultana, Papia
    Zhou, Xuhong
    THIN-WALLED STRUCTURES, 2009, 47 (6-7) : 807 - 815
  • [28] Web crippling of cold-formed steel built-up box sections
    He, Jun
    Young, Ben
    Thin-Walled Structures, 2022, 171
  • [29] Web crippling of cold-formed steel built-up box sections
    He, Jun
    Young, Ben
    THIN-WALLED STRUCTURES, 2022, 171
  • [30] Improved design procedure for battened cold-formed steel built-up columns composed of lipped angles
    Anbarasu, M.
    Dar, M. Adil
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 164