A High-Throughput Fluorometric Method for Quantitation of Besifloxacin Hydrochloride Using Microplate Reader

被引:2
|
作者
Abd El-Hay, Soad S. [1 ,2 ]
El-Sayed, Heba M. [1 ]
机构
[1] Zagazig Univ, Analyt Chem Dept, Fac Pharm, Zagazig 44519, Egypt
[2] King Abdulaziz Univ, Pharmaceut Chem Dept, Fac Pharm, Jeddah, Saudi Arabia
关键词
Besifloxacin; fluorescamine; high-throughput method; fluorescence; microplate reader; hydrochloride; LIQUID-CHROMATOGRAPHY; AMINO-ACIDS; FLUORESCAMINE;
D O I
10.2174/1573412913666170126143008
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objective: The present study describes the development and validation of a simple high-throughput method for the fluorometric determination of besifloxacin HCl in 96-microwell plates. Methods: The proposed method is based on the reaction between besifloxacin HCl and fluorescamine in borate buffer solution of pH 8.5 giving a highly fluorescent derivative that was developed simultaneously and measured at 471 nm after excitation at 353 nm. The different experimental conditions affecting the fluorescence reaction were carefully investigated and optimized. Results: The method showed linearity over the concentration range of 200-1000 ng/mL with low Limits Of Detection (LOD) and Quantitation (LOQ) of 8.47 ng/mL and 28.24 ng/mL, respectively. The Relative Standard Deviation (% RSD) and Relative Error (% RE) values did not exceed 3 % for precision and accuracy respectively. The developed high-throughput method was successfully applied for the determination of besifloxacin HCl in simulated tears and eye drops. Conclusion: The capability of the method for measuring micro-volume samples makes it convenient for handling a very large number of samples simultaneously. In addition, using micro-well plates can offer a safer and economic method for the determination of besifloxacin HCl in pharmaceutical dosage forms.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [41] High-throughput microplate assay for the determination of drug partition coefficients
    Magalhaes, Luis M.
    Nunes, Claudia
    Lucio, Marlene
    Segundo, Marcela A.
    Reis, Salette
    Lima, Jose L. F. C.
    NATURE PROTOCOLS, 2010, 5 (11) : 1823 - 1830
  • [42] High-Throughput Validated Method for the Quantitation of Busulfan in Plasma Using Ultrafast SPE-MS/MS
    Danso, Darlington
    Jannetto, Paul J.
    Enger, Robert
    Langman, Loralie J.
    THERAPEUTIC DRUG MONITORING, 2015, 37 (03) : 319 - 324
  • [43] High-throughput method for the quantitation of total folate in whole blood using LC-MS/MS
    Owens, Janel E.
    Holstege, Dirk M.
    Clifford, Andrew J.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (09) : 3292 - 3297
  • [44] High-throughput biosensing of neurotoxic insecticides using polystyrene microplate-immobilized acetylcholinesterase
    Zhang, Yaodong
    Cai, Yanan
    Li, Li
    Qian, Yunxia
    Lu, Lu
    ANALYTICAL METHODS, 2012, 4 (11) : 3830 - 3835
  • [45] High-throughput microplate assay for the determination of drug partition coefficients
    Luís M Magalhães
    Cláudia Nunes
    Marlene Lúcio
    Marcela A Segundo
    Salette Reis
    José L F C Lima
    Nature Protocols, 2010, 5 : 1823 - 1830
  • [46] Quantitation of secreted proteins using mCherry fusion constructs and a fluorescent microplate reader
    Duellman, Tyler
    Burnett, John
    Yang, Jay
    ANALYTICAL BIOCHEMISTRY, 2015, 473 : 34 - 40
  • [47] A clarifying reagent and microplate-based method for the high-throughput analysis of lipase activity in milk
    Weiqing Zhang
    Bo Wang
    Changlu Ma
    Xiaoyang Pang
    Jiaping Lv
    European Food Research and Technology, 2021, 247 : 2161 - 2169
  • [48] Quantitative Beutler test for newborn mass screening of galactosemia using a fluorometric microplate reader
    Fujimoto, A
    Okano, Y
    Miyagi, T
    Isshiki, G
    Oura, T
    CLINICAL CHEMISTRY, 2000, 46 (06) : 806 - 810
  • [49] A clarifying reagent and microplate-based method for the high-throughput analysis of lipase activity in milk
    Zhang, Weiqing
    Wang, Bo
    Ma, Changlu
    Pang, Xiaoyang
    Lv, Jiaping
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2021, 247 (09) : 2161 - 2169
  • [50] RAPID METHOD FOR DETERMINING AMYLOSE USING A MICROPLATE READER