High-throughput biosensing of neurotoxic insecticides using polystyrene microplate-immobilized acetylcholinesterase

被引:2
|
作者
Zhang, Yaodong [1 ,2 ]
Cai, Yanan [1 ,2 ]
Li, Li [1 ,2 ]
Qian, Yunxia [1 ,2 ]
Lu, Lu [1 ,2 ]
机构
[1] Minist Educ, Key Lab Appl Surface & Colloid Chem, Xian 710062, Peoples R China
[2] Shaanxi Normal Univ, Sch Chem & Chem Engn, Key Lab Analyt Chem Life Sci Shaanxi Prov, Xian 710062, Peoples R China
基金
中国国家自然科学基金;
关键词
CARBAMATE INSECTICIDES; PESTICIDE-RESIDUES; SOLID-PHASE; ORGANOPHOSPHATE; REACTIVATION; AFFINITY; ASSAY; DEALKYLATION; EXTRACTION; MILK;
D O I
10.1039/c2ay25774b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Acetylcholinesterase (AChE) inhibition-based biosensors can be used as a screening test for neurotoxic insecticides. A high-throughput AChE inhibition assay was developed via AChE immobilized on a microplate using enzyme-linked immunosorbent assay (ELISA) reader. The presence of insecticide was confirmed by reactivation of the inhibited AChE immobilized on the microplate. The polystyrene (PS) surface of the microplates was first modified with amine groups. The aminated 96-well microplate was modified further with chitosan to generate more amine groups. Thus, AChE could be covalently immobilized onto the aminated microplate via cross-linking with glutaraldehyde. The activity of the immobilized AChE upon surface modification with chitosan was 12-fold higher than without spacer molecules. The activity of the immobilized AChE was measured before and after incubation with test samples to calculate the inhibition rate. The calibration curves showed a linear response ranging between 1.0 and 20.0 mu g L-1 for paraoxon with detection limits (3 sigma) of 0.5 mu g L-1 in buffer or organic milk. This assay format was applied directly to determine the insecticide in real milk samples with recovery rate 89-108%. The developed microplate assay format could be used as a convenient tool for high-throughput prescreening of insecticides in samples to increase the number of tested samples and ensure consumer safety.
引用
收藏
页码:3830 / 3835
页数:6
相关论文
共 50 条
  • [1] An Improved Automated High-Throughput Efficient Microplate Reader for Rapid Colorimetric Biosensing
    Yang, Jinhu
    Wu, Yue
    Wang, Hao
    Yang, Wenjian
    Xu, Zhongyuan
    Liu, Dong
    Chen, Hui-Jiuan
    Zhang, Diming
    BIOSENSORS-BASEL, 2022, 12 (05):
  • [2] Development of Metal Nanoparticle-immobilized Microplate for High-throughput and Highly Sensitive Fluorescence Analysis
    Kyohei Matsui
    So Tanabe
    Shuyi Sun
    Dung Nguyen
    Takamasa Kinoshita
    Yojiro Yamamoto
    Hiroshi Shiigi
    Analytical Sciences, 2020, 36 : 1461 - 1465
  • [3] Development of Metal Nanoparticle-immobilized Microplate for High-throughput and Highly Sensitive Fluorescence Analysis
    Matsui, Kyohei
    Tanabe, So
    Sun, Shuyi
    Nguyen, Dung
    Kinoshita, Fahhmso
    Yamamoto, Yojiro
    Shiigi, Hiroshi
    ANALYTICAL SCIENCES, 2020, 36 (12) : 1461 - 1465
  • [4] High-throughput antibody screening using high-sensitivity microplate cytometry
    Wayne Bowen
    Nature Methods, 2010, 7 (12) : 8 - 9
  • [5] Determination of Oxidoreductase Activity Using a High-Throughput Microplate Respiratory Measurement
    Hommes, Gregor
    Gasser, Christoph A.
    Ammann, Erik M.
    Corvini, Philippe F. -X.
    ANALYTICAL CHEMISTRY, 2013, 85 (01) : 283 - 291
  • [6] High-Throughput Determination of Enantiopurity by Microplate Circular Dichroism
    Pilicer, Samantha L.
    Dragna, Justin M.
    Garland, Adam
    Welch, Christopher J.
    Anslyn, Eric, V
    Wolf, Christian
    JOURNAL OF ORGANIC CHEMISTRY, 2020, 85 (16): : 10858 - 10864
  • [7] Microplate spectrophotometry for high-throughput screening of cytotoxic molecules
    Tomelleri, C.
    Dalla Pellegrina, C.
    Chignola, R.
    CELL PROLIFERATION, 2010, 43 (02) : 130 - 138
  • [8] High-throughput measurements of the optical redox ratio using a commercial microplate reader
    Cannon, Taylor M.
    Shah, Amy T.
    Walsh, Alex J.
    Skala, Melissa C.
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (01)
  • [9] A High-Throughput Fluorometric Method for Quantitation of Besifloxacin Hydrochloride Using Microplate Reader
    Abd El-Hay, Soad S.
    El-Sayed, Heba M.
    CURRENT PHARMACEUTICAL ANALYSIS, 2018, 14 (03) : 198 - 203
  • [10] Biochemical characterization and immobilization of Erwinia carotovora L-asparaginase in a microplate for high-throughput biosensing of L-asparagine
    Labrou, Nikolaos E.
    Muharram, Magdy Mohamed
    ENZYME AND MICROBIAL TECHNOLOGY, 2016, 92 : 86 - 93