Intrastromal corneal ring segments: visual outcomes from a large case series

被引:41
|
作者
Ferrara, Guilherme [1 ,2 ]
Torquetti, Leonardo [1 ]
Ferrara, Paulo [1 ]
Merayo-Lloves, Jesus [2 ]
机构
[1] Paulo Ferrara Eye Clin, Belo Horizonte, MG, Brazil
[2] Fernandez Vega Eye Inst, Oviedo, Spain
来源
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY | 2012年 / 40卷 / 05期
关键词
cornea; corneal topography; keratoconus; FEMTOSECOND LASER; KERATOCONUS; IMPLANTATION; ASPHERICITY; MANAGEMENT;
D O I
10.1111/j.1442-9071.2011.02698.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To evaluate the clinical safety and efficacy of implanted Ferrara intrastromal corneal ring segments in a large sample of patients with ectatic corneal disease. Design: Retrospective, consecutive case series. Samples: A total of 1073 eyes of 810 patients consecutively operated from January 2006 to July 2008 were evaluated. Methods: Two groups were created according to the type of ring implanted: Group 1 patients implanted with the 160 degrees of arc ring and Group 2 patients implanted with the 210 degrees of arc ring. Main Outcome Measures: Uncorrected visual acuity, best-corrected visual acuity, keratometry, asphericity and pachymetry at the thinnest point of the cornea. All patients were evaluated using a corneal tomography (Pentacam, Oculus, Inc., Lynnwood, WA, USA). Results: For Group 1 patients, uncorrected visual acuity increased to 20/80, best-corrected visual acuity increased to 20/40, asphericity decreased to -0.35, spherical equivalent decreased to -2.26 D and keratometry decreased to 45.72 D (P < 0.001 for each compared with preoperative values). For Group 2 patients, uncorrected visual acuity increased to 20/130, best-corrected visual acuity increased to 20/60, asphericity decreased to -0.56, spherical equivalent decreased to -4.14 D and keratometry decreased to 48.10 D (P < 0.001 for each compared with preoperative values). The 210 degrees intrastromal corneal ring segments reduced keratometry and asphericity more than the 160 degrees intrastromal corneal ring segments did. The complication rate was 3.82%. Conclusions: Ferrara intrastromal corneal ring segments implantation is safe and effective and has a low complication rate. It can effectively reduce the corneal steepening and improve uncorrected visual acuity and best-corrected visual acuity in patients with keratoconus.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [31] KeraRing Intrastromal Corneal Ring Segments for Correction of Keratoconus
    Gharaibeh, Almutez M.
    Muhsen, Sana' M.
    AbuKhader, Ilham B.
    Ababneh, Osama H.
    Abu-Ameerh, Mohammed A.
    Albdour, Muawyah D.
    CORNEA, 2012, 31 (02) : 115 - 120
  • [32] Paradoxical central corneal steepening after collagen crosslinking in a case with intrastromal corneal ring segments
    Abad, Juan Carlos
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (10): : 1879 - 1880
  • [33] Intrastromal corneal ring segments delay corneal grafting in patients with keratoconus
    Beniz, Luiz Arthur F.
    Queiroz, Gustavo H.
    Queiroz, Carlos F.
    Lopes, Wanessa L.
    Moraes, Leiser F.
    Beniz, Jose
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2016, 79 (01) : 30 - 32
  • [34] Combination of corneal crosslinking and intrastromal corneal ring segments for the treatment of keratoconus
    Zhang, Zhen-Yong
    Zhang, Xing-Ru
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (10): : 1878 - 1879
  • [35] Recent advances in the treatment of corneal ectasia with intrastromal corneal ring segments
    Poulsen, David M.
    Kang, Joann J.
    CURRENT OPINION IN OPHTHALMOLOGY, 2015, 26 (04) : 273 - 277
  • [36] Deep corneal neovascularization after implantation with intrastromal corneal ring segments
    Al-Torbak, A
    Al-Amri, A
    Wagoner, MD
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (05) : 926 - 927
  • [37] Decision making nomogram for intrastromal corneal ring segments in keratoconus
    Shetty, Rohit
    D'Souza, Sharon
    Ramachandran, Sarika
    Kurian, Mathew
    Nuijts, Rudy M. M. A.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (01) : 23 - 28
  • [38] Confocal microscopy after implantation of intrastromal corneal ring segments
    Ruckhofer, J
    Böhnke, M
    Alzner, E
    Grabner, G
    OPHTHALMOLOGY, 2000, 107 (12) : 2144 - 2151
  • [39] Comparison of 2 types of intrastromal corneal ring segments for keratoconus
    Haddad, Walid
    Fadlallah, Ali
    Dirani, Ali
    El Rami, Hala
    Fahd, Daoud
    Khanafer, Dana
    Fahed, Sharbel
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07): : 1214 - 1221
  • [40] Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus
    Dauwe, Caroline
    Touboul, David
    Roberts, Cynthia J.
    Mahmoud, Ashraf M.
    Kerautret, Julien
    Fournier, Pierre
    Malecaze, Francois
    Colin, Joseph
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (10): : 1761 - 1767