摘要
Background: To evaluate the clinical safety and efficacy of implanted Ferrara intrastromal corneal ring segments in a large sample of patients with ectatic corneal disease. Design: Retrospective, consecutive case series. Samples: A total of 1073 eyes of 810 patients consecutively operated from January 2006 to July 2008 were evaluated. Methods: Two groups were created according to the type of ring implanted: Group 1 patients implanted with the 160 degrees of arc ring and Group 2 patients implanted with the 210 degrees of arc ring. Main Outcome Measures: Uncorrected visual acuity, best-corrected visual acuity, keratometry, asphericity and pachymetry at the thinnest point of the cornea. All patients were evaluated using a corneal tomography (Pentacam, Oculus, Inc., Lynnwood, WA, USA). Results: For Group 1 patients, uncorrected visual acuity increased to 20/80, best-corrected visual acuity increased to 20/40, asphericity decreased to -0.35, spherical equivalent decreased to -2.26 D and keratometry decreased to 45.72 D (P < 0.001 for each compared with preoperative values). For Group 2 patients, uncorrected visual acuity increased to 20/130, best-corrected visual acuity increased to 20/60, asphericity decreased to -0.56, spherical equivalent decreased to -4.14 D and keratometry decreased to 48.10 D (P < 0.001 for each compared with preoperative values). The 210 degrees intrastromal corneal ring segments reduced keratometry and asphericity more than the 160 degrees intrastromal corneal ring segments did. The complication rate was 3.82%. Conclusions: Ferrara intrastromal corneal ring segments implantation is safe and effective and has a low complication rate. It can effectively reduce the corneal steepening and improve uncorrected visual acuity and best-corrected visual acuity in patients with keratoconus.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [21] Clinical outcomes after intrastromal corneal ring segments reoperation in keratoconus patients
    Torquetti, Leonardo
    Ferrara, Guilherme
    Almeida, Franklin
    Cunha, Leandro
    Ferrara, Paulo
    Merayo-Lloves, Jesus
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (06) : 796 - 800
  • [22] Intrastromal corneal ring segments:: Reversibility of refractive effect
    Asbell, PA
    Ucakhan, ÖÖ
    Abbott, RL
    Assil, KA
    Burris, TE
    Durrie, DS
    Lindstrom, RL
    Schanzlin, DJ
    Verity, SM
    Waring, GO
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (01) : 25 - 31
  • [23] Tonometry after Intrastromal Corneal Ring Segments for Keratoconus
    Arribas-Pardo, Paula
    Mendez-Hernandez, Carmen
    Cuina-Sardina, Ricardo
    Manuel Benitez-del-Castillo, Jose
    Garcia-Feijoo, Julian
    OPTOMETRY AND VISION SCIENCE, 2017, 94 (10) : 986 - 992
  • [24] Corneal Allogenic Intrastromal Ring Segments: A Literature Review
    Levy, Issac
    Mukhija, Ritika
    Nanavaty, Mayank A.
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)
  • [25] Clinical and Histological Reversibility of Intrastromal Corneal Ring Segments
    Lbares-Frias, L.
    Gallego, P.
    Martinez, M. C.
    Cantalapiedra, R.
    Perez-Merino, P.
    del Olmo, S.
    Alcalde, I.
    Blanco, T.
    Merayo-Lloves, J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [26] Intraocular pressure following intrastromal corneal ring segments
    Arribas-Pardo, Paula
    Mendez-Hernandez, Carmen
    Cuina-Sardina, Ricardo
    Manuel Benitez-del-Castillo, Jose
    Garcia-Feijoo, Julian
    ACTA OPHTHALMOLOGICA, 2018, 96 (01) : E98 - E100
  • [27] Intrastromal corneal ring segments for the treatment of irregular astigmatism
    Kymionis, George D.
    Bouzoukis, Dimitrios I.
    Haft, Payman
    Siganos, Charambos S.
    Yoo, Sonia
    EXPERT REVIEW OF OPHTHALMOLOGY, 2008, 3 (01) : 9 - 15
  • [28] Ferrara intrastromal corneal ring segments for severe keratoconus
    Miranda, D
    Sartori, M
    Francesconi, C
    Allemann, N
    Ferrara, P
    Campos, M
    JOURNAL OF REFRACTIVE SURGERY, 2003, 19 (06) : 645 - 653
  • [29] Keratitis after implantation of intrastromal corneal ring segments
    Shehadeh-Masha'our, R
    Modi, N
    Barbara, A
    Garzozi, HJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (08): : 1802 - 1804
  • [30] Reversibility and. exchangeability of intrastromal corneal ring segments
    Chan, SM
    Khan, HN
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04): : 676 - 681