On-line separation of short-lived nuclei by a multi-reflection time-of-flight device

被引:105
|
作者
Wolf, R. N. [1 ]
Beck, D. [2 ]
Blaum, K. [3 ]
Boehm, Ch. [3 ]
Borgmann, Ch. [3 ]
Breitenfeldt, M. [4 ]
Herfurth, F. [2 ]
Herlert, A. [5 ]
Kowalska, M. [6 ]
Kreim, S. [3 ,6 ]
Lunney, D. [7 ]
Naimi, S. [7 ,8 ]
Neidherr, D. [2 ]
Rosenbusch, M. [1 ]
Schweikhard, L. [1 ]
Stanja, J. [9 ]
Wienholtz, F. [1 ]
Zuber, K. [9 ]
机构
[1] Ernst Moritz Arndt Univ Greifswald, Inst Phys, D-17489 Greifswald, Germany
[2] GSI Helmholtzzentrum Schwerionenforsch GmbH, D-64291 Darmstadt, Germany
[3] Max Planck Inst Kernphys, D-69117 Heidelberg, Germany
[4] Katholieke Univ Leuven, Inst Kern & Stralingsfys, B-3001 Heverlee, Belgium
[5] FAIR GmbH, D-64291 Darmstadt, Germany
[6] CERN, CH-1211 Geneva 23, Switzerland
[7] Univ Paris 11, CSNSM CNRS IN2P3, F-91405 Orsay, France
[8] RIKEN, RIKEN Nishina Ctr Accelerator Based Sci, Wako, Saitama 3510198, Japan
[9] Tech Univ Dresden, Inst Kern & Teilchenphys, D-01069 Dresden, Germany
关键词
MR-ToF mass separator; Isobar purification; RIB; ISOLTRAP; Penning trap; Mass spectrometer; RADIOACTIVE ION-BEAMS; ACCURACY MASS-SPECTROMETRY; CYLINDRICAL PENNING TRAP; HIGH-PRECISION; ISOLTRAP; PURIFICATION; RESOLUTION; NUCLIDES; ISOTOPES; SYSTEM;
D O I
10.1016/j.nima.2012.05.067
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A multi-reflection time-of-flight (MR-ToF) mass analyzer has been integrated into ISOLTRAP, the precision mass spectrometer for on-line mass determinations of short-lived nuclides at ISOLDE/CERN. The new instrument improves ISOLTRAP by providing a fast separation of isobaric contaminant species as well as subsequent ion selection using the fast Bradbury-Nielsen gate. Suppression ratios of up to 10(4) and mass-resolving powers of over 10(5) have been reached in off-line experiments. Preliminary data from on-line applications illustrate the benefit and performance of the device and its potential in the context of the ISOLTRAP setup. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 90
页数:9
相关论文
共 50 条
  • [21] Simulations of a proof-of-principle experiment for collinear laser spectroscopy within a multi-reflection time-of-flight device
    Maier, F. M.
    Fischer, P.
    Heylen, H.
    Lagaki, V.
    Lechner, S.
    Plattner, P.
    Sels, S.
    Wienholtz, F.
    Noertershaeuser, W.
    Schweikhard, L.
    Malbrunot-Ettenauer, S.
    HYPERFINE INTERACTIONS, 2019, 240 (1):
  • [22] A novel ion cooling trap for multi-reflection time-of-flight mass spectrograph
    Ito, Y.
    Schury, P.
    Wada, M.
    Naimi, S.
    Smorra, C.
    Sonoda, T.
    Mita, H.
    Takamine, A.
    Okada, K.
    Ozawa, A.
    Wollnik, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 317 : 544 - 549
  • [23] Multiple active voltage stabilizations for multi-reflection time-of-flight mass spectrometry
    Fischer, Paul
    Schweikhard, Lutz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (06):
  • [24] Simulations of a proof-of-principle experiment for collinear laser spectroscopy within a multi-reflection time-of-flight device
    F. M. Maier
    P. Fischer
    H. Heylen
    V. Lagaki
    S. Lechner
    P. Plattner
    S. Sels
    F. Wienholtz
    W. Nörtershäuser
    L. Schweikhard
    S. Malbrunot-Ettenauer
    Hyperfine Interactions, 2019, 240
  • [25] First off-line tests and performance of the Notre Dame multi-reflection time-of-flight mass spectrometer
    Kelly, J. M.
    Brodeur, M.
    Liu, B.
    Campagna, Q.
    Gonzales, C.
    Maier, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 463 : 485 - 487
  • [26] A multi-reflection time-of-flight mass spectrometer for the offline ion source of the PUMA experiment
    Schlaich, M.
    Fischer, J.
    Fischer, P.
    Klink, C.
    Obertelli, A.
    Schmidt, A.
    Schweikhard, L.
    Wienholtz, F.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2024, 495
  • [27] Construction and simulation of a multi-reflection time-of-flight mass spectrometer at the University of Notre Dame
    Schultz, B. E.
    Kelly, J. M.
    Nicoloff, C.
    Long, J.
    Ryan, S.
    Brodeur, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 376 : 251 - 255
  • [28] Towards ultrahigh-resolution multi-reflection time-of-flight mass spectrometry at ISOLTRAP
    Wienholtz, F.
    Atanasov, D.
    Kreim, S.
    Manea, V.
    Rosenbusch, M.
    Schweikhard, L.
    Welker, A.
    Wolf, R. N.
    PHYSICA SCRIPTA, 2015, T166
  • [29] A multi-reflection time-of-flight setup for the study of atomic clusters produced by magnetron sputtering
    Giesel, Paul F.
    Fischer, Paul
    Schweikhard, Lutz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (02):
  • [30] A multi-reflection time-of-flight mass separator for isobaric purification of radioactive ion beams
    Wolf, Robert N.
    Eritt, Markus
    Marx, Gerrit
    Schweikhard, Lutz
    HYPERFINE INTERACTIONS, 2011, 199 (1-3): : 115 - 122