Simulations of a proof-of-principle experiment for collinear laser spectroscopy within a multi-reflection time-of-flight device

被引:12
|
作者
Maier, F. M. [1 ]
Fischer, P. [2 ]
Heylen, H. [3 ]
Lagaki, V. [2 ,3 ]
Lechner, S. [3 ,4 ]
Plattner, P. [3 ,5 ]
Sels, S. [2 ,3 ]
Wienholtz, F. [2 ,3 ]
Noertershaeuser, W. [6 ]
Schweikhard, L. [2 ]
Malbrunot-Ettenauer, S. [3 ]
机构
[1] Johannes Kepler Univ Linz, Altenbergerstr 69, A-4040 Linz, Austria
[2] Ernst Moritz Arndt Univ Greifswald, Inst Phys, D-17487 Greifswald, Germany
[3] CERN, Expt Phys Dept, ISOLDE, CH-1211 Geneva 23, Switzerland
[4] Tech Univ Wien, Karlspl 13, A-1040 Vienna, Austria
[5] Univ Innsbruck, Innrain 52, A-6020 Innsbruck, Austria
[6] Tech Univ Darmstadt, Inst Kernphys, D-64289 Darmstadt, Germany
来源
HYPERFINE INTERACTIONS | 2019年 / 240卷 / 1期
基金
欧洲研究理事会;
关键词
Multi-reflection time-of-flight device; Collinear laser spectroscopy; Exotic radionuclides; MIRACLS; ION; CHARGE; SEPARATION; ISOTOPES; STORAGE; TRAPS;
D O I
10.1007/s10751-019-1575-x
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
For nearly four decades Collinear Laser Spectroscopy (CLS) has been employed to determine ground-state properties of short-lived radionuclides. To extend its reach to the most exotic radionuclides with very low production yields, the novel Multi Ion Reflection Apparatus for CLS (MIRACLS) is currently under development at ISOLDE/CERN. In this setup, 30-keV ion bunches will be trapped between two electrostatic mirrors of a multi-reflection time-of-flight (MR-ToF) device such that the laser beam will probe the ions during each revolution. Thus, the observation time will be extended and the experimental sensitivity will be increased significantly while maintaining the high resolution of conventional CLS. A proof-of-principle experiment is currently being performed to demonstrate the potential of CLS within a low-energy MR-ToF device. Its first experimental results benchmark the validity of ion-optical simulations from the CLS perspective, which will also be applied to MIRACLS' 30-keV apparatus.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Simulations of a proof-of-principle experiment for collinear laser spectroscopy within a multi-reflection time-of-flight device
    F. M. Maier
    P. Fischer
    H. Heylen
    V. Lagaki
    S. Lechner
    P. Plattner
    S. Sels
    F. Wienholtz
    W. Nörtershäuser
    L. Schweikhard
    S. Malbrunot-Ettenauer
    Hyperfine Interactions, 2019, 240
  • [2] Multi-Reflection Time-of-Flight Mass Spectroscopy for Superheavy Nuclides
    Schury, Peter
    Ito, Yuta
    Niwase, Toshitaka
    Wada, Michiharu
    ATOMS, 2023, 11 (10)
  • [3] A multi-reflection time-of-flight mass spectrometer for the offline ion source of the PUMA experiment
    Schlaich, M.
    Fischer, J.
    Fischer, P.
    Klink, C.
    Obertelli, A.
    Schmidt, A.
    Schweikhard, L.
    Wienholtz, F.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2024, 495
  • [4] Delayed Bunching for Multi-Reflection Time-of-Flight Mass Separation
    Rosenbusch, M.
    Chauveau, P.
    Delahaye, P.
    Marx, G.
    Schweikhard, L.
    Wienholtz, F.
    Wolf, R. N.
    NON-NEUTRAL PLASMA PHYSICS IX, 2015, 1668
  • [5] MULTI-REFLECTION TIME-OF-FLIGHT ION TRAP WITH ISOCHRONOUS DRIFT
    Grinfeld, D.
    Hock, C.
    Stewart, H.
    Makarov, A.
    RECENT TRENDS IN CHARGED PARTICLE OPTICS AND SURFACE PHYSICS INSTRUMENTATION, 2018, : 22 - 22
  • [6] Imaging properties of a multi-reflection time-of-flight mass analyzer
    Verenchikov, Anatoly N.
    Yavor, Mikhail I.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 463
  • [7] Designing a multi-reflection time-of-flight mass analyzer for LPT
    Tian, Y. L.
    Wang, Y. S.
    Wang, J. Y.
    Zhou, X. H.
    Huang, W. X.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2016, 408 : 28 - 32
  • [8] A multi-reflection time-of-flight analyzer with a long focus lens
    Stewart, Hamish
    Grinfeld, Dmitry
    Venckus, Aivaras
    Peterson, Amelia
    Hagedorn, Bernd
    Ostermann, Robert
    Denisov, Eduard
    Garland, Matthew
    Wagner, Alexander
    Makarov, Alexander
    Hock, Christian
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2024, 505
  • [9] A multi-reflection time-of-flight mass analyzer at IMP/CAS
    Wang, Jun-Ying
    Tian, Yu-Lin
    Wang, Yong-Sheng
    Gan, Zai-Guo
    Zhou, Xiao-Hong
    Xu, Hu-Shan
    Huang, Wen-Xue
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 463 (463): : 179 - 183
  • [10] On-line separation of short-lived nuclei by a multi-reflection time-of-flight device
    Wolf, R. N.
    Beck, D.
    Blaum, K.
    Boehm, Ch.
    Borgmann, Ch.
    Breitenfeldt, M.
    Herfurth, F.
    Herlert, A.
    Kowalska, M.
    Kreim, S.
    Lunney, D.
    Naimi, S.
    Neidherr, D.
    Rosenbusch, M.
    Schweikhard, L.
    Stanja, J.
    Wienholtz, F.
    Zuber, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 686 : 82 - 90