Right thoracotomy for aortic valve replacement in the adolescents with bicuspid aortic valve

被引:2
|
作者
Giordano, Raffaele [1 ]
Cantinotti, Massimiliano [2 ,3 ]
Comentale, Giuseppe [1 ]
Di Tommaso, Luigi [1 ]
Iannelli, Gabriele [1 ]
Pilato, Emanuele [1 ]
Palma, Gaetano [1 ]
机构
[1] Univ Naples Federico II, Dept Adv Biomed Sci, Div Adult & Pediat Cardiac Surg, Naples, Italy
[2] Tuscany Fdn G Monasterio CNR Reg Toscana, Massa, Italy
[3] Tuscany Fdn G Monasterio CNR Reg Toscana, Pisa, Italy
关键词
aortic; pediatric cardiac surgery; thoracotomy; RECOMMENDATIONS; MINITHORACOTOMY; MINISTERNOTOMY;
D O I
10.1111/chd.12680
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In this study, we compared our experience about early and midterm follow-up outcomes for right anterolateral minithoracotomy (RAMT) vs full sternotomy (FS) in surgical aortic valve replacement (AVR) among adolescents with bicuspid aortic valve (BAV). Methods Patients were retrospectively enrolled from January 2008 to December 2017. Inclusion criteria were patients with BAV who had to undergo to AVR. They were divided in two groups: RAMT and FS. The choice of RAMT was based on individual surgeon's preferences or when expressly requested by patient that was informed of nonconventional approach. Results We enrolled 61 patients, 23 in RAMT group and 38 in FS group. The mean age was 15.6 +/- 1.7 years for RAMT group and 16.1 +/- 1.5 years for FS group (P = .23). The RAMT group had a higher prevalence of female gender (P = .04). The patients in the RAMT group had longer cardiopulmonary bypass (115.2 +/- 18.5 vs 102.2 +/- 16.5 min; P = .006) and cross-clamp time (78.6 +/- 18.1 vs 74.3 +/- 15.2 min; P = .01). No patients required intraoperative conversion to FS. No differences were found in ventilation times, postoperative intensive care unit (ICU), and hospital length of stay for both groups. Follow-up echocardiograms were available for all patients at median of 5.2 years (range 0.5-9.6 years, median 5.4 years for RAMT and 5.1 for FS) and no patient required reoperation for aortic prosthesis malfunction. Conclusions Our study shows that RAMT is safe and effective as FS. Although the RAMT operation takes slightly more operation time, it is not associated with major adverse effects.
引用
下载
收藏
页码:162 / 166
页数:5
相关论文
共 50 条
  • [41] Predictors of aortic events after aortic valve replacement for bicuspid valve stenosis Reply
    Girdauskas, Evaldas
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 44 (02) : 399 - 399
  • [42] Transcatheter Valve Replacement for Bicuspid Aortic Stenosis
    Otto, Catherine M.
    Newby, David E.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 326 (11): : 1009 - 1010
  • [43] Haemodynamic flow abnormalities in bicuspid aortic valve disease improve with aortic valve replacement
    Malenka M Bissell
    Margaret Loudon
    Aaron T Hess
    Victoria Stoll
    Elizabeth Orchard
    Stefan Neubauer
    Saul G Myerson
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [44] Valve Phenotype and Risk Factors of Aortic Dilatation After Aortic Valve Replacement in Japanese Patients With Bicuspid Aortic Valve
    Kinoshita, Takeshi
    Naito, Shiho
    Suzuki, Tomoaki
    Asai, Tohru
    CIRCULATION JOURNAL, 2016, 80 (06) : 1356 - 1361
  • [45] Valve-sparing aortic root replacement and the bicuspid aortic valve: The details matter
    Girardi, Leonard N.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (04): : 1412 - 1413
  • [46] Bicuspid Aortic Valve What to Image in Patients Considered for Transcatheter Aortic Valve Replacement?
    Kong, William K. F.
    Delgado, Victoria
    Bax, Jeroen J.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2017, 10 (09)
  • [47] Aortic valve repair versus replacement in bicuspid aortic valve disease - Meeting discussion
    Chitwood, WR
    Davierwala, P
    Collart, F
    Acar, C
    Mestres, CA
    JOURNAL OF HEART VALVE DISEASE, 2003, 12 (06): : 686 - 686
  • [48] Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis Using Lotus Valve System
    Chan, Albert W.
    Wong, Daniel
    Charania, Jahangir
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (01) : 157 - 163
  • [49] Impact of Hospital Procedural Volume on Transcatheter Aortic Valve Replacement for Bicuspid Aortic Valve
    Kassis, Nicholas
    Saad, Anas M.
    Hariri, Essa
    Gad, Mohamed M.
    Abdelfattah, Omar M.
    Yun, James J.
    Reed, Grant W.
    Puri, Rishi
    Krishnaswamy, Amar
    Kapadia, Samir R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (15) : 1841 - 1843
  • [50] Valve-sparing aortic root replacement in bicuspid aortic valve: as good as in tricuspid?
    Holubec, Tomas
    Van Linden, Arnaud
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2023, 63 (04)