Right thoracotomy for aortic valve replacement in the adolescents with bicuspid aortic valve

被引:2
|
作者
Giordano, Raffaele [1 ]
Cantinotti, Massimiliano [2 ,3 ]
Comentale, Giuseppe [1 ]
Di Tommaso, Luigi [1 ]
Iannelli, Gabriele [1 ]
Pilato, Emanuele [1 ]
Palma, Gaetano [1 ]
机构
[1] Univ Naples Federico II, Dept Adv Biomed Sci, Div Adult & Pediat Cardiac Surg, Naples, Italy
[2] Tuscany Fdn G Monasterio CNR Reg Toscana, Massa, Italy
[3] Tuscany Fdn G Monasterio CNR Reg Toscana, Pisa, Italy
关键词
aortic; pediatric cardiac surgery; thoracotomy; RECOMMENDATIONS; MINITHORACOTOMY; MINISTERNOTOMY;
D O I
10.1111/chd.12680
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In this study, we compared our experience about early and midterm follow-up outcomes for right anterolateral minithoracotomy (RAMT) vs full sternotomy (FS) in surgical aortic valve replacement (AVR) among adolescents with bicuspid aortic valve (BAV). Methods Patients were retrospectively enrolled from January 2008 to December 2017. Inclusion criteria were patients with BAV who had to undergo to AVR. They were divided in two groups: RAMT and FS. The choice of RAMT was based on individual surgeon's preferences or when expressly requested by patient that was informed of nonconventional approach. Results We enrolled 61 patients, 23 in RAMT group and 38 in FS group. The mean age was 15.6 +/- 1.7 years for RAMT group and 16.1 +/- 1.5 years for FS group (P = .23). The RAMT group had a higher prevalence of female gender (P = .04). The patients in the RAMT group had longer cardiopulmonary bypass (115.2 +/- 18.5 vs 102.2 +/- 16.5 min; P = .006) and cross-clamp time (78.6 +/- 18.1 vs 74.3 +/- 15.2 min; P = .01). No patients required intraoperative conversion to FS. No differences were found in ventilation times, postoperative intensive care unit (ICU), and hospital length of stay for both groups. Follow-up echocardiograms were available for all patients at median of 5.2 years (range 0.5-9.6 years, median 5.4 years for RAMT and 5.1 for FS) and no patient required reoperation for aortic prosthesis malfunction. Conclusions Our study shows that RAMT is safe and effective as FS. Although the RAMT operation takes slightly more operation time, it is not associated with major adverse effects.
引用
下载
收藏
页码:162 / 166
页数:5
相关论文
共 50 条
  • [31] Progressive ascending aortic dilation following aortic valve replacement in bicuspid aortic valve disease
    Factor, A.
    Curtin, R.
    Hinchinson, J.
    EUROPEAN HEART JOURNAL, 2013, 34 : 860 - 860
  • [32] Successful Transcatheter Aortic Valve Replacement for the Treatment of Severe Aortic Stenosis with Bicuspid Aortic Valve
    Jung, Sung-Yun
    Choi, KangUn
    Lee, Jung-Hee
    Lee, Chan-Hee
    Son, Jang-Won
    Kim, Ung
    Park, Jong-Seon
    Shin, Dong-Gu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (16) : S290 - S291
  • [33] The fate of the bicuspid valve aortopathy after aortic valve replacement
    Charitos, Efstratios I.
    Stierle, Ulrich
    Petersen, Michael
    Mohamed, Salah A.
    Hanke, Thorsten
    Schmidtke, Claudia
    Klotz, Stefan
    Sievers, Hans-Hinrich
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 45 (05) : E128 - E135
  • [34] Minimally invasive aortic valve replacement via anterior right thoracotomy
    Andreas M.
    Mahr S.
    Kocher A.
    Laufer G.
    Zeitschrift für Herz-,Thorax- und Gefäßchirurgie, 2017, 31 (4) : 241 - 246
  • [35] Anterior Right Thoracotomy for Rapid-Deployment Aortic Valve Replacement
    Wiedemann, Dominik
    Laufer, Guenther
    Coti, Iuliana
    Mahr, Stephane
    Scherzer, Sabine
    Haberl, Thomas
    Kocher, Alfred
    Andreas, Martin
    ANNALS OF THORACIC SURGERY, 2021, 112 (02): : 564 - 571
  • [36] Endovascular aortic replacement in a patient with bicuspid aortic valve disease
    Matti, Sofia
    Estrella, Maria Laura
    Llobera, Mariano Napoli
    Colla, Julian
    Blanco, Rodrigo
    Blanco, Federico
    Szarfer, Jorge
    Gagliardi, Juan A.
    MEDICINA-BUENOS AIRES, 2023, 83 (01) : 126 - 128
  • [37] Transcatheter aortic valve replacement in patients with bicuspid aortic valves
    Patel, Amisha
    Leon, Martin B.
    JOURNAL OF THORACIC DISEASE, 2018, 10 : S3568 - S3572
  • [38] Aortic replacement for bicuspid aortic valve aortopathy: When and why?
    Braverman, Alan C.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (02): : 520 - 525
  • [39] Clinical outcome and echocardiographic predictors of aortic valve replacement in patients with bicuspid aortic valve
    Ahmed, Shaheeda
    Honos, George N.
    Walling, Anne D.
    Michel, Caroline M.
    Sebag, Igal A.
    Rudski, Lawrence G.
    Therrien, Judith
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (08) : 998 - 1003
  • [40] Valve-sparing aortic root replacement in a bicuspid aortic valve with papillary fibroelastoma
    Kondov, Stoyan
    Kari, Fabian Alexander
    Czerny, Martin
    Siepe, Matthias
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 25 (04) : 671 - 673