Comparison of mitral annular shape and function in different forms of myxomatous valve disease using real-time three-dimensional transesophageal echocardiography

被引:0
|
作者
Apor, A. [1 ]
Sax, B. [1 ]
Hutti, T. [2 ]
Nagy, A. [1 ]
Kovacs, A. [1 ]
Merkely, B. [1 ]
机构
[1] Semmelweis Univ, Ctr Heart, H-1085 Budapest, Hungary
[2] Semmelweis Univ, Dept Cardiac Surg, H-1085 Budapest, Hungary
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:17 / 17
页数:1
相关论文
共 50 条
  • [31] Abnormal mitral-aortic intervalvular coupling in mitral valve diseases: a study using real-time three-dimensional transesophageal echocardiography
    Looi, Jen-Li
    Lee, Alex Pui-Wai
    Fang, Fang
    Hsiung, Ming C.
    Sun, Jing-Ping
    Yin, Wei-Hsian
    Wei, Jeng
    Tsai, Shen-Kou
    Wan, Song
    Wong, Randolph H. L.
    Underwood, Malcolm J.
    Lin, Qing-Shan
    Jin, Chun-Na
    Chen, Liu
    Yu, Cheuk-Man
    CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (10) : 831 - 842
  • [32] Mitral Valve Repair for Double-Orifice Mitral Valve With Flail Leaflet: The Usefulness of Real-Time Three-Dimensional Transesophageal Echocardiography
    Tani, Tomoko
    Kim, Kitae
    Fujii, Yoko
    Komori, Shigeru
    Okada, Yukikatsu
    Kita, Toru
    Furukawa, Yutaka
    ANNALS OF THORACIC SURGERY, 2012, 93 (04): : E97 - E98
  • [33] Impact of Transcatheter Aortic Valve Replacement on the Mitral Valve Apparatus and Mitral Regurgitation: A Real-Time Three-Dimensional Transesophageal Echocardiography Study
    Shibayama, Kentaro
    Harada, Kenji
    Mihara, Hirotsugu
    Tanaka, Jun
    Berdejo, Javier
    Gurudevan, Swaminatha V.
    Siegel, Robert
    Jilaihawi, Hasan
    Makkar, Raj R.
    Shiota, Takahiro
    CIRCULATION, 2013, 128 (22)
  • [34] Effect of Transcatheter Aortic Valve Replacement on the Mitral Valve Apparatus and Mitral Regurgitation Real-Time Three-Dimensional Transesophageal Echocardiography Study
    Shibayama, Kentaro
    Harada, Kenji
    Berdejo, Javier
    Mihara, Hirotsugu
    Tanaka, Jun
    Gurudevan, Swaminatha V.
    Siegel, Robert
    Jilaihawi, Hasan
    Makkar, Raj R.
    Shiota, Takahiro
    CIRCULATION-CARDIOVASCULAR IMAGING, 2014, 7 (02) : 344 - 351
  • [35] Quantitative Description of Mitral Valve Geometry Using Real-Time Three-Dimensional Echocardiography
    Ryan, Liam P.
    Jackson, Benjamin M.
    Eperjesi, Thomas J.
    Plappert, Theodore J.
    St John-Sutton, Martin
    Gorman, Robert C.
    Gorman, Joseph H., III
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2007, 2 (05) : 237 - 244
  • [36] Automated tracking of mitral annular motion using two-dimensional echocardiography for evaluation of left ventricular function: A comparison with real-time three-dimensional echocardiography
    Eto, Y
    Shiota, T
    Yamada, H
    Qin, JX
    Tsujino, H
    Agler, DA
    Shin, JH
    Saracino, G
    Greenberg, NL
    Thomas, JD
    CIRCULATION, 2002, 106 (19) : 507 - 507
  • [37] Predictive value of left atrial volumes assessed using real-time three-dimensional echocardiography for pulmonary hypertension in dogs with myxomatous mitral valve disease
    Woo, In-Sun
    Kim, Jung-Hyun
    FRONTIERS IN VETERINARY SCIENCE, 2024, 11
  • [38] Dynamic Indices of Mitral Valve Function Using Perioperative Three-Dimensional Transesophageal Echocardiography
    Bartels, Karsten
    Thiele, Robert H.
    Phillips-Bute, Barbara
    Glower, Donald D.
    Swaminathan, Madhav
    Kisslo, Joseph
    Mackensen, G. Burkhard
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (01) : 18 - 24
  • [39] Obstructed Bi-leaflet Prosthetic Mitral Valve Imaging with Real-time Three-dimensional Transesophageal Echocardiography
    Shimbo, Mai
    Watanabe, Hiroyuki
    Kimura, Shunsuke
    Terada, Mai
    Iino, Takako
    Iino, Kenji
    Ito, Hiroshi
    JOURNAL OF CLINICAL ULTRASOUND, 2015, 43 (01) : 64 - 67
  • [40] Guiding the percutaneous mitral valve repair by real-time three-dimensional transesophageal echocardiography: Beyond procedural navigation
    Watanabe, Nozomi
    JOURNAL OF CARDIOLOGY, 2018, 71 (3-4) : 327 - 328