Dynamic Indices of Mitral Valve Function Using Perioperative Three-Dimensional Transesophageal Echocardiography

被引:21
|
作者
Bartels, Karsten [1 ]
Thiele, Robert H. [1 ,2 ]
Phillips-Bute, Barbara [1 ]
Glower, Donald D. [3 ]
Swaminathan, Madhav [1 ]
Kisslo, Joseph [4 ]
Mackensen, G. Burkhard [5 ]
机构
[1] Duke Univ, Med Ctr, Dept Anesthesiol, Div Cardiothorac Anesthesiol & Crit Care Med, Durham, NC USA
[2] Univ Virginia, Sch Med, Dept Anesthesiol, Charlottesville, VA 22908 USA
[3] Duke Univ, Med Ctr, Dept Surg, Div Cardiovasc & Thorac Surg, Durham, NC 27710 USA
[4] Duke Univ, Med Ctr, Div Cardiol, Durham, NC 27710 USA
[5] Univ Washington, Dept Anesthesiol & Pain Med, Div Cardiothorac Anesthesiol, Seattle, WA 98195 USA
关键词
echocardiography; ultrasound; mitral valve; perioperative; computer applications; 2D TEE; 3D TEE; dynamic indices; ANNULAR GEOMETRY; REGURGITATION; QUANTIFICATION; ANNULOPLASTY; SEVERITY; REPAIR; RECOMMENDATIONS; COMPLEXITY; GUIDELINES; ACCURACY;
D O I
10.1053/j.jvca.2013.03.024
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Perioperative transesophageal echocardiography is essential for decision-making for mitral valve surgery. While two-dimensional transesophageal echocardiography represents the standard of care, tracking of dynamic changes using three-dimensional imaging permits assessment of morphologic and functional characteristics of the mitral valve. The authors hypothesized that quantitative three-dimensional analysis would reveal distinct differences among diseased, repaired, and normal mitral valves. Design: Case-control observational clinical study. Setting: Tertiary care hospital. Participants: Using novel mitral valve quantification software, the authors retrospectively analyzed 80 datasets of cardiac surgery patients who underwent intraoperative transesophageal echocardiographic imaging. Twenty patients with degenerative mitral regurgitation were evaluated before and after mitral valve repair. Twenty patients had functional mitral regurgitation, and 20 patients had no mitral valve disease. Measurements and Main Results: Primary outcome measures of dynamic mitral valve function were: 1) three-dimensional annulus area, 2) annular displacement distance, 3) annular displacement velocity, and 4) annular area fraction. Other mitral annular tracking indices, in addition to intraobserver reliability and interobserver agreement, also were reported. Annulus area was enlarged in degenerative and functional mitral regurgitation. Annular displacement distance was decreased in functional mitral regurgitation and repaired valves. Annular displacement velocity was decreased in functional mitral regurgitation. Annular area fraction was decreased in functional mitral regurgitation and repaired valves. Intraobserver reliability and interobserver agreement were high for all 4 analyzed indices. Conclusions: Normal, functional regurgitant, degenerative, and repaired mitral valves have distinctly different dynamic signatures of anatomy and function as reliably determined by perioperative echocardiographic tracking. (c) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 50 条
  • [1] Three-dimensional reconstruction of mitral valve by transesophageal echocardiography
    Elmaghraby, Ahmed Mohamed
    Salustri, Alessandro
    [J]. HEART VIEWS, 2019, 20 (04): : 178 - 179
  • [2] Live three-dimensional transesophageal echocardiography in mitral valve surgery
    MA NingLI ZhianMENG Xu and YANG Ya Department of Ultrasonography Department of Cardiac Surgery Beijing Anzhen HospitalCapital Medical UniversityBeijing China
    [J]. 中华医学杂志(英文版), 2008, (20) : 2037 - 2041
  • [3] Three-dimensional transesophageal echocardiography in mitral valve repair and replacement
    Dzhanketova, V. S.
    Golukhova, E. Z.
    Mashina, T. V.
    Shamsiev, G. A.
    Mrikaev, D. V.
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 : 412 - 413
  • [4] Live three-dimensional transesophageal echocardiography in mitral valve surgery
    Ma Ning
    Li Zhi-An
    Meng Xu
    Yang Ya
    [J]. CHINESE MEDICAL JOURNAL, 2008, 121 (20) : 2037 - 2041
  • [5] Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography
    Kupferwasser, I
    MohrKahaly, S
    Menzel, T
    Spiecker, M
    Dohmen, G
    Mayer, E
    Oelert, H
    Erbel, R
    Meyer, J
    [J]. INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1996, 12 (04): : 241 - 247
  • [6] Quantitative Assessment of Mitral Valve Coaptation Using Three-Dimensional Transesophageal Echocardiography
    Cobey, Frederick C.
    Swaminathan, Madhav
    Phillips-Bute, Barbara
    Hyca, Martin
    Glower, Donald D.
    Douglas, Pamela S.
    Shaw, Andrew D.
    Mathew, Joseph P.
    Mackensen, G. Burkhard
    [J]. ANNALS OF THORACIC SURGERY, 2014, 97 (06): : 1998 - 2004
  • [7] Mitral Annular Morphology in Mitral Valve Disease with Three-Dimensional Transesophageal Echocardiography
    Tani, Tomoko
    Kawai, Junichi
    Kitai, Takeshi
    Kim, Kitae
    Okada, Yukikatsu
    Kita, Toru
    Furukawa, Yutaka
    [J]. JOURNAL OF HEART VALVE DISEASE, 2014, 23 (02): : 193 - 199
  • [8] Three-Dimensional Transesophageal Echocardiography Shows Dehiscence of Mitral Valve Repair
    Iida, Ryoji
    Shanks, Miriam
    [J]. TEXAS HEART INSTITUTE JOURNAL, 2012, 39 (05) : 772 - 773
  • [9] Cleft Posterior Mitral Valve Leaflet: Identification Using Three-Dimensional Transesophageal Echocardiography
    Townsley, Matthew M.
    Chen, Edward P.
    Sniecinski, Roman M.
    [J]. ANESTHESIA AND ANALGESIA, 2010, 111 (06): : 1366 - 1367
  • [10] Parachute mitral valve accompanied by bicuspid aortic valve on three-dimensional transesophageal echocardiography
    Feng, Tian-Ying
    Li, Zhi-An
    He, Yi-Hua
    Han, Jian-Cheng
    Luan, Shu-Rong
    Wang, Lin-Lin
    [J]. KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2012, 28 (09): : 506 - 508