Single-Phase Ground Fault Test of Overhead Power Lines in Ungrounded Power Grids of 6-10 kV

被引:0
|
作者
Fedotov, Aleksander [1 ]
Vagapov, Georgii [1 ]
Basirov, Rafik [2 ]
Abdullin, Linar [3 ]
Grackova, Larisa [4 ]
机构
[1] Kazan State Power Engn Univ, Dept Methods Increase Power Supply Reliabil & Pow, Kazan, Russia
[2] Kazan Natl Res Tech Univ, Dept Tech Phys, Kazan, Russia
[3] Grid Co, Vysokogorsky Power Grids, Kazan, Russia
[4] Inst Phys Energet, Lab Energy Syst Anal & Optimisat, Riga, Latvia
关键词
power system simulation; power system harmonics; transmission lines;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
At the present time, the requirements to reliability and continuity of power supply in electrical grids of 6 - 35 kV voltage with ungrounded neutral are continuously becoming stricter. The overhead power lines are the least reliable components of power supply systems. Early diagnosis and early elimination of damages on overhead power lines is one of the priority tasks for power supply systems. This paper reviews theoretical and practical points of using voltage and current frequency spectrum characteristics during a single-phase ground fault in a small grid of overhead power lines with ungrounded neutral.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Selection of Frequency Estimation of 6-10 kV-Overhead Lines' Technical Condition Based on Reliability Statistical Studies
    Basmanov, V. G.
    Kholmanskikh, V. M.
    PROBLEMELE ENERGETICII REGIONALE, 2020, (04): : 23 - 34
  • [42] On Single-Phase Earth Faults in a 20-kV Power Network
    Maiorov A.V.
    Chelaznov A.A.
    Shuntov A.V.
    Maiorov, A.V. (journal-elektrotechnika@mail.ru), 2018, Pleiades journals (89) : 398 - 401
  • [43] Fault diagnosis of a customer substation of 10 kV single power supply
    Xia, Yu
    Wang, Jinpeng
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2010, 30 (02): : 201 - 204
  • [44] A novel fault line selection algorithm of single-phase ground faults in ungrounded neutral system using wavelets transform
    Shu, HC
    Xiao, B
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 2532 - 2536
  • [45] Power spectrum of fault phase voltage based single-phase adaptive reclosure
    Zhou, Niancheng
    Ye, Tian
    Huang, Rui
    Zhang, Jingwei
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1287 - 1292
  • [46] Fault phase selection of a single-phase tree-line in a 10 kV distribution line
    Yang, Sen
    Chen, Tianxiang
    Shao, Qianqiu
    Wang, Meng
    Chen, Long
    Yang, Longshan
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (18): : 169 - 178
  • [47] Research of Single-Phase Faults in 6-35 KV Branched Overhead Distribution Network
    Krasnykh, A. A.
    Krivoshein, I. L.
    Kozlov, A. L.
    2017 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2017,
  • [48] Device for Generating Voltage to Test the Insulation of Power Cable Lines of 6 – 10 kV Distribution Networks
    Yurov A.A.
    Lukonin A.V.
    Storozhenko D.E.
    Kuimov D.N.
    Power Technology and Engineering, 2023, 57 (4) : 633 - 636
  • [49] USE OF SINGLE-PHASE OVERHEAD TEST LINES AND TEST CAGES TO EVALUATE CORONA EFFECTS OF EHV AND UHV TRANSMISSION-LINES
    COMBER, MG
    ZAFFANELLA, LE
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1974, PA93 (01): : 81 - 90
  • [50] Single-phase motors fault current contribution to the electrical power system
    Hamza, ASHA
    AbdelGawad, NMK
    ENERGY CONVERSION AND MANAGEMENT, 1997, 38 (02) : 115 - 130