Single-Phase Ground Fault Test of Overhead Power Lines in Ungrounded Power Grids of 6-10 kV

被引:0
|
作者
Fedotov, Aleksander [1 ]
Vagapov, Georgii [1 ]
Basirov, Rafik [2 ]
Abdullin, Linar [3 ]
Grackova, Larisa [4 ]
机构
[1] Kazan State Power Engn Univ, Dept Methods Increase Power Supply Reliabil & Pow, Kazan, Russia
[2] Kazan Natl Res Tech Univ, Dept Tech Phys, Kazan, Russia
[3] Grid Co, Vysokogorsky Power Grids, Kazan, Russia
[4] Inst Phys Energet, Lab Energy Syst Anal & Optimisat, Riga, Latvia
关键词
power system simulation; power system harmonics; transmission lines;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
At the present time, the requirements to reliability and continuity of power supply in electrical grids of 6 - 35 kV voltage with ungrounded neutral are continuously becoming stricter. The overhead power lines are the least reliable components of power supply systems. Early diagnosis and early elimination of damages on overhead power lines is one of the priority tasks for power supply systems. This paper reviews theoretical and practical points of using voltage and current frequency spectrum characteristics during a single-phase ground fault in a small grid of overhead power lines with ungrounded neutral.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Development of an algorithm for identifying single-phase ground fault conditions in cable and overhead lines in the networks with isolated neutral
    Achitaev, Andrey A.
    Suslov, Konstantin V.
    Volkova, Irina O.
    Kozhemyakin, Vyacheslav E.
    Dvoryansky, Yuri V.
    ENERGY REPORTS, 2023, 9 : 1079 - 1086
  • [22] Investigation of the Methods of Optimization of the Fault Location Process in 6-10 kV Urban Power Networks.
    Radkevich, V.N.
    Nichiporovich, L.V.
    Izvestiya Vysshikh Uchebnykh Zavedenij i Energeticheskikh Ob''edinenij Sng. Energetika, 1977, (01): : 107 - 108
  • [23] The choice of the method of neutral grounding in 6-10 kv power networks
    Yevdokunin, GA
    Gudilin, SV
    Korepanov, AA
    ELECTRICAL TECHNOLOGY RUSSIA, 1998, (04): : 104 - 127
  • [24] Detection Method for Tree-contact Single-phase-to-ground Fault of 10 kV Overhead Line
    Liang D.
    Xu B.
    Wang P.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (14): : 149 - 157
  • [25] DETERMINATION OF THE CAPACITANCE VALUE OF THE CONDUCTOR-INSULATOR-PIN SYSTEM IN 6-10 kV OVERHEAD POWER LINES TO ASSESS THE FEASIBILITY OF EARLY DIAGNOSTICS OF THE INSULATION CONDITION
    Buinyi, R.O.
    Bezruchko, V.M.
    Strogii, A.Yu.
    Technical Electrodynamics, 2024, 2024 (06): : 77 - 80
  • [26] Protection of 6-kV TPP Auxiliary Grids with Two Neutral Ground Modes from Single-Phase Ground Faults
    Ya. M. Kanevskii
    Power Technology and Engineering, 2003, 37 (5) : 323 - 325
  • [27] Remote Control Determining the Location of Power Lines Damaged with Single Phase Ground Fault
    Oshchepkov, V. A.
    Gorunov, V. N.
    Vladimirov, L. V.
    2016 2ND INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2016,
  • [28] Effect of single-phase power system on waggons - spread of voltage unbalance in 110 kV lines
    Palecek, Josef
    Miculka, Petr
    Kolar, Vaclav
    PROCEEDINGS OF THE 12TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2011, 2011, : 262 - 265
  • [29] SINGLE-PHASE POWER DISTRIBUTION-SYSTEM POWER FLOW AND FAULT ANALYSIS
    HALPIN, SM
    GRIGSBY, LL
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1992, 28 (04) : 1033 - 1041
  • [30] Reduction of Active Power Losses in Overhead Power Transmission Lines Rated for 6-35 kV
    Latypov, I. S.
    Sushkov, V. V.
    2016 DYNAMICS OF SYSTEMS, MECHANISMS AND MACHINES (DYNAMICS), 2016,