Evaluation of an immobilised macrocyclic material for on-line column preconcentration and separation of cadmium, copper and lead for electrothermal atomic absorption spectrometry

被引:45
|
作者
Hosten, E [1 ]
Welz, B [1 ]
机构
[1] Bodenseewerk Perkin Elmer & Co GmbH, Dept Appl Res, D-88662 Uberlingen, Germany
关键词
flow injection on-line preconcentration; macrocyclic materials; electrothermal atomic absorption spectrometry;
D O I
10.1016/S0003-2670(99)00052-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of trace amounts of Cd, Cu and Pb in riverine, estuarine, sea water and in urine samples, using a flow injection on-line preconcentration procedure coupled with electrothermal atomic absorption spectrometry, was investigated, The sorption material used consists of macrocyclic ligand immobilised on a silica gel support. The sample at pH 1.6 is loaded onto a 50 mu l column for a specific time interval. The column is then washed with a dilute nitric acid solution (pH 3) and emptied by pumping air through the column. The column is eluted with 40 mu l of 2.5 mol l(-1) nitric acid solution and the eluate introduced into the electrothermal atomiser. Detection limits (3 sigma) of 0.8, 46 and 20 ng l(-1) were obtained for Cd, Cu and Pb, respectively. The accuracy of the procedure was tested with water and urine certified reference materials. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:55 / 65
页数:11
相关论文
共 50 条
  • [31] Flow injection on-line sorption preconcentration of platinum in a knotted reactor coupled with electrothermal atomic absorption spectrometry
    Ivanova, E
    Adams, F
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (05): : 445 - 450
  • [32] Determination of Lead in Seawater by Flow-Injection On-line Preconcentration–Electrothermal Atomic Absorption Spectrometry after Coprecipitation with Iron(III) Hydroxide
    Junichi Nakajima
    Yoshihiro Hirano
    Koichi Oguma
    Analytical Sciences, 2003, 19 : 585 - 588
  • [33] Determination of cadmium and lead in high purity uranium compounds by flame atomic absorption spectrometry with on-line micro-column preconcentration by CL-7301 resin
    Bo-ping Li
    Ming-biao Luo
    Jiang-qiang Li
    Wei Liu
    Yu-zhen Sun
    Guo-long Guo
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 : 3 - 8
  • [34] Determination of cadmium and lead in high purity uranium compounds by flame atomic absorption spectrometry with on-line micro-column preconcentration by CL-7301 resin
    Li, Bo-ping
    Luo, Ming-biao
    Li, Jiang-qiang
    Liu, Wei
    Sun, Yu-zhen
    Guo, Guo-long
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 278 (01) : 3 - 8
  • [35] Flow injection on-line sorption separation and preconcentration with a knotted reactor for electrothermal atomic absorption spectrometric determination of lead in biological and environmental samples
    Yan, XP
    Adams, F
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) : 459 - 464
  • [36] On-line coupling of flow injection microcolumn separation and preconcentration to electrothermal atomic absorption spectrometry for determination of (ultra)trace selenite and selenate in water
    Yan, XP
    Sperling, M
    Welz, B
    ANALYTICAL CHEMISTRY, 1999, 71 (19) : 4353 - 4360
  • [37] New developments in flow injection/sequential injection on-line separation and preconcentration coupled with electrothermal atomic absorption spectrometry for trace metal analysis
    Wang, Yang
    Chen, Ming-Li
    Wang, Jian-Hua
    APPLIED SPECTROSCOPY REVIEWS, 2007, 42 (02) : 103 - 118
  • [38] Synthetic zeolites as sorbent material for on-line preconcentration of copper traces and its determination using flame atomic absorption spectrometry
    de Peña, YP
    López, W
    Burguera, JL
    Burguera, M
    Gallignani, M
    Brunetto, R
    Carrero, P
    Rondon, C
    Imbert, F
    ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) : 249 - 258
  • [39] Determination of lead and cadmium in urine by electrothermal atomization atomic absorption spectrometry
    Vasil'eva, L. A.
    Grinshtein, I. L.
    Gucer, S.
    Izgi, B.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (07) : 649 - 654
  • [40] Optimization of flame atomic absorption spectrometry with preconcentration by flow-injection on-line sorbent extraction of cadmium and lead in biological materials
    Bruhn, CG
    Vilches, C
    Cid, HJ
    BOLETIN DE LA SOCIEDAD CHILENA DE QUIMICA, 1999, 44 (03): : 321 - 335